Laserfiche WebLink
AdvancedGeo <br /> 12 October 2020 An Employee-Owned Company <br /> Project No. 20-6164 <br /> Page 4 of 15 <br /> 3.5. GENERAL AREA SEPTIC PERMIT HISTORY <br /> The following is a summary of information based on new septic system installation permits <br /> currently on file with EHD. <br /> ADDRESS: 21211 East Ashton Lane <br /> LOCATION: Approximately 220 feet to south-southwest <br /> SEPTIC SYSTEM: 1) Permit date January 2004; new installation of septic system: 1,600- <br /> gallon concrete tank with two compartments, distribution box (D-Box), 15 leaching <br /> chambers, two 60-foot long leach lines, and one 25-foot deep seepage pit. <br /> ADDRESS: 21270 East Ashton Lane <br /> LOCATION: Approximately 250 feet to south-southeast <br /> SEPTIC SYSTEM: 1) Permit date November 2004; new installation of septic system: <br /> 1,600-gallon concrete tank with two compartments, distribution box (D-Box), 15 leaching <br /> chambers, three 40-foot long leach lines, and one 25-foot deep seepage pit. <br /> ADDRESS: 21196 East Ashton Lane <br /> LOCATION: Approximately 300 feet to south <br /> SEPTIC SYSTEM: 1) Permit date November 2003; new installation of septic system: <br /> 1,600-gallon concrete tank with two compartments, distribution box (D-Box), 15 leaching <br /> chambers, two 60-foot long leach lines, and one 25-foot deep seepage pit. <br /> ADDRESS: 21300 East Ashton Lane <br /> LOCATION: Approximately 600 feet to southeast <br /> SEPTIC SYSTEM: 1) Permit date November 2003; new installation of septic system: <br /> 1,250-gallon concrete tank with two compartments, distribution box (D-Box), 15 leaching <br /> chambers, three 40-foot long leach lines, and one 25-foot deep seepage pit. <br /> ADDRESS: 21056 East Copperopolis <br /> LOCATION: Approximately 650 feet to northwest <br /> SEPTIC SYSTEM: 1) Permit date July 1986, new installation of septic system: 1,200- <br /> gallon concrete tank with two compartments, distribution box (D-Box), two 80-foot long <br /> leach lines, and two 25-foot deep seepage pits. <br /> 3.6. PROPOSED MAXIMUM SEPTIC TANK USAGE ON SITE <br /> The current residence on the property has four (4) bedrooms and utilizes the existing <br /> septic system 365 days per year. The existing septic system will not be altered from the <br /> current configuration. The average and reasonable maximum usage of wastewater for a <br /> four-bedroom home by residents is 100 gallons per day (gpd) for the first bedroom and <br /> 50 gpd for each additional bedroom for a total of 250 gpd. <br /> The new proposed septic system is planned to be located in the eastern portion of the <br /> property over 100 feet away from the existing domestic water well. The proposed septic <br />