Laserfiche WebLink
C\� <br /> DIRECT WASTE LINE I 2''� D U N H A M <br /> I TRAP PRIMER VALVE (TP-1) CONNECTION FOR �I <br /> O4 WH-1 I i ll / <br /> EXTEND AND CONNECT 1/2" 3-COMP SINK <br /> TRAP PRIMER PIPING TO AREA SHALL BE COPPER N �2,, Dunham Associates of Minnesota, Inc. <br /> MECHANICAL CONTRACTOR SHALL PROVIDE 3 - I FLOOR DRAIN WITH TRAP PRIMER 50 South Sixth Street/Suite 1100 <br /> SEISMIC BRACING FOR ALL MECHANICAL O M I TP-1 CONNECTIONS COORDINATE I L Minneapolis,Minnesota 55402-1540 <br /> EQUIPMENT, DUCTWORK, PIPING ETC. PER I t I ROUTING. C C PHONE 612.465.7550 FAx 612.465.7551 <br /> LATEST CMC AND CALIFORNIA TITLE 24 / 51� I I I O 2'' P3 P5 FD TP-1 P6TMV-1 WEE dunhameng.com <br /> REQUIREMENTS. P3 mechanical +electrical consulting engineering <br /> � 3 <br /> JPROJECT NO. 0421743-001 <br /> PROVIDE INSULATION ON HOT & COLD =N / Q N <br /> WATER LINES PER SPECIFICATIONS ON �I��� FD / *L 1 DN:CN=Gregory M A0141000g gg0„6B, <br /> VACUUM RELIEF 1 5 I 1 ' = ❑affiliated,C=US <br /> " SHEET M P 1 . �'' O CO 20.08.,,08:20:58-05'00, !� <br /> BY P.C. 3/4 / TMV-1 / LA M33481 Z <br /> 'n <br /> � � m <br /> HEAT TRAP (TYP) NOTE: THREE COMPARTMENT -` O � y R1 <br /> GATE/BALL VALVE �HW SINK SHALL DRAIN DIRECT TO ` / 1 u�, N m <br /> BY P.C. (TYP.) INSULATE ALL PIPING y�� P6 THE SEWER LINE WITH AN / g� or <br /> IN ACCORDANCE WITH O ADJACENT FLOOR DRAIN PLACED <br /> cl-CW SPECIFICATIONS. UP STREAM PER SEWER LINE `�,, P6 �OFcauF° 8/11/2020 <br /> FLOW PER 2019 CPC, SECTION / O <br /> 704.3 CODE REQUIREMENTS. ` I I _ 1 <br /> " � _ UNION BY P.C. TYP. `N <br /> 3/4 (TYP.) <br /> 3/4' T & P RELIEF <br /> VALVE BY P.C. BIZ �N`�� N A'' FCO I P1 <br /> THERMAL EXPANSION TANK: AMT R WATER HEATER = = I v <br /> MODEL ST-5-C, OR EQUAL. TANK TO / <br /> BE DIAPHRAGM TYPE, <br /> PRE-PRESSURIZED TO 40 PSIG ANDI <br /> ly <br /> RELIEF VALVE SET AT 150 PSIG. I <br /> 00 <br /> TANK SHALL BE ASME CERTIFIED. 2" WIDE, 20 GA. SHEET TMV-1 1 P2 MBA Architects, Inc. <br /> INSTALL PER LOCAL CODE & METAL BAND, SECURE TO <br /> MANUFACTURER'S RECOMMENDATIONS. WALL FOR SEISMIC I P1 1 N5560 CTH ZM, SUITE .3 <br /> (SUPPLIED AND INSTALLED BY BRACING WHERE REQUIRED <br /> CONTRACTOR) BY CODE. P2 CO N FCO Onalaska, WI. 54650 <br /> 608-785-2760 CELL: 507-4.58-8034. <br /> DRAIN VALVE BY P.C. GALV. DRIP PAN I P2 1 E-mail: mbopm.t.im@gmail.com <br /> BY P.C. TEMPERED MIXING VALVE <br /> 6 TMV-1 (TMV-1). TYPICAL FOR ALL <br /> HAND SINK(S) AND LAVATORY. 1 <br /> SET TO 110 DEC F (TYP.) / I <br /> P 4 '0000,`L <br /> REFER TO ARCHITECTURAL DRAWINGS FOR � <br /> WATER HEATER PLATFORM FRAMING DETAIL SEPARATE 3/4" DRAINS - P4 I <br /> DISCHARGE AT MOP SINK I F <br /> CLIENT'S <br /> STORE NUMBER SF-94 <br /> I <br /> 3 WATER PIPING RISER DIAGRAM 2 WASTE & VENT PIPING RISER DIAGRAM <br /> 4 WATER HEATER (WH - 1 )ABOVE MOP SINK DETAIL P1 NOT TO SCALE P1 � � SEE' S CANDIES <br /> P 1 NO SCALE NOT TO SCALE <br /> 4TMV-1 <br /> i 1 <br /> ELECTRIC WATER HEATER SCHEDULE <br /> 0 <br /> TAG MANUFACTURER MODEL NO. CAPACITY (GAL) KW STAGES RECOVER RATE GALLONSPER HOUR VOLTS NOTES 1 <br /> WH-1 RHEEM ELD-30 30 10 1 68 GPH @ 60 `F RISE SEE ELECT. (2) 5000 W HEATING ELEMENTS HEATING SIMULTANEOUSLY. yoJ MANTE.CA CA 9536 <br /> 51 GPH @ 80 `F RISE REFER TO DETAIL 4/P1. (A.0 SMITH IS AN APPROVED EQUAL.) <br /> NOTE: SEE'S CANDIES DOES NOT PROCESS/MAKE CANDY <br /> PLUMBING FIXTURE SCHEDULE <br /> AT THIS STORE. CANDY IS MADE OFF SITE. <br /> MARK TYPE SUPPORT W V CW HW REMARKS <br /> D D <br /> MANUFACTURE AND rl_'� <br /> 1 PLUMBING PLAN 0 0 <br /> MODEL NUMBER SCALE: 1/4!' - V-0" <br /> � D <br /> CADET FLOWWISE RIGHT HEIGHT 3423 S LA. CIENEGA BLVD. <br /> P1 WATER CLOSET ELONGATED BOWL, PRESSURE FLOOR MOUNT 3" 2" 1/2" - 1 .1 GALLONS PER FLUSH LOS ANGELES, CA 90016 <br /> PRESSURE ASSIST ASSISTED FLUSH, 1 .1 GPF PH: 310/2.67-4616 <br /> MODEL 2467.100 FAX: 310/842.-4436 <br /> FAUCET: AMERICAN STANDARD SELECTRONIC, <br /> MODEL # 6055.204. 0.35 GPM PRESSURE SEE'S CONTACT <br /> P2 LAVATORY LUCERNE (WHITE) WALL HUNG 1 1/2" 1 1/2" 1/2" 1/2" COMPENSATING, VANDAL-RESISTANT, RICHARD ESCALANTE <br /> 0355.012 NON-AERATED SPRAY, CR-P2 LITHIUM 310/ 287-4616 <br /> AMERICAN STANDARD BATTERY IN <br /> CESEC. RUNNING TIME, <br /> 0.044 GALPERCYCLE. FIXTURE AND WATER CALCULATION <br /> KEY NOTES Tim R. Benson <br /> ARCHITECT'S PROJECT' MANAGER <br /> PROVIDE W/ MR-371 FAUCET, HOSE, <br /> HOT AND COLD WATER WASTE 1 CONNECT NEW SANITARY WASTE LINE TO EXISTING 4' SANITARY WASTE LINE. VERIFY SIZE, 608/ 785-2760 <br /> N O <br /> HOSE BRACKET, MOP HANGER, MR-375 z ROUTING AND INVERT IN FIELD. `a <br /> � TOTAL o •• <br /> MOP SINK FLORESTONE MSR-2424 STRAINER, & MR-374 LOK SEAL. w w w w w w O CONNECT NEW 2" VENT TO EXISTING MIN. 2" VENT STACK ROUTED UP THRU ROOF. VERIFY ° <br /> P3 FLOOR MOUNT 3" 2 3/4" 3/4" HOSE ATTACHEMENT ON FAUCET SHALL w � FIXTURE z LL_ 0' w � w 2 / .� a•- a 0 <br /> BASIN (MOLDED STONE) o � m o > > J Of SIZE AND ROUTING IN FIELD. c 4- 'D <br /> BE EQUIPPED WITH AN ANTI-SIPHON � UNITS M w w D Q a� c <br /> VACUUM BREAKER. MARK DESCRIPTION Z 11 LL: z CW HW O af - ° '-� X � '-` date -62 a. 0 > comments <br /> - <br /> MARK � cn z � I O EXTEND AND CONNECT NEW 3/4" CW LINE TO THE EXISTING CW LINE SERVICE SERVING <br /> P1 WATER CLOSET 1 2.5 2.5 2.5 4" 1 4 4 TENANT'S SPACE. FIELD VERIFY SIZE AND ROUTING IN FIELD. VERIFY SUB-METER AS <br /> 07/03/200 <br /> FAUCET: DELTA MODEL 27C4854. .. REQUIREMENTS WITH LANDLORD PRIOR TO BID. <br /> GOOSNECK SPOUT - 4.5" SPOUT P2 LAVATORY 1 1 .75 .75 1 1 1/2 1 1 1 PRELIM O 07/31/2000 <br /> REACH, VANDAL RESISTANT 0.5 GPM REVIEW 4 ELECTRIC WATER HEATER TO BE INSTALLED ABOVE MOP SINK ON THE PLATFORM. SEE <br /> NON-AERATING SPRAY OPUTLET, ADA P4, P6 HAND SINK 2 1 2 3 3 4 1 1/2" 2 2 4 ARCHITECTURAL DRAWINGS FOR PLATFORM INFORMATION. REFER TO DETAIL 4/P1. PERMIT 08/11/20 00 O 010 <br /> P4 MINI-HAND KOHLER MODEL K6579 WHITE COUNTER TOP 1 1/2" 1 1/2" 1/2" 1/2" COMPLIANT 4" BLADE HANDLES P3 MOP SINK 1 3 2 2 3 3" 1 3 3 <br /> SINK 3-HOLE CAST IRON O ROUTE CW DN IN WING WALL AND INSTALL MAIN SHUT-OFF VALVE AT 60" A.F.F.. AFTER <br /> COLOR TO BE BRIGHT WHITE. FS FLOOR DRAIN - 3" 1 5 5 SHUT-OFF VALVE, ROUTE COLD WATER UP INTO CEILING PLENUM SPACE. REFER TO <br /> P5 3-COMP SINK 1 1.5 1.13 1.13 1.5 1 2" 1 2 2 ARCHITECTURAL DETAIL 1/A5 AND WATER PIPING RISER DIAGRAM. COORDINATE ROUTING IN <br /> TENANT'S CONTRACTOR TO SUPPLY TOTAL 6 >< 9.4 6.9 12.0 >< 7 1 19 FIELD. LABEL WATER SHUT-OFF ON ACCESS PANEL. <br /> REGENCY MODEL 60OS31515215 AND INSTALL SCULLERY SINK, TOTAL F.U. 12.0 <br /> P5 3 <br /> SINK P (G.C. FURNISHED) FLOOR MOUNT 2" - 3/4" 3/4" FAUCET (T&S B266) AND TRIM. G.P.M 11 <br /> PROVIDE WITH 1.5 GPM PRESSURE STATIC PRESSURE RANGE (50 - 60) P.S.I. <br /> COMPENSATING AERATOR. LOSSES <br /> drawn by. checked by: <br /> P6 HAND SINK W/ SIDE ADVANCE WALL HUNG 1 1/2" 1 1/2" 1/2" 1/2" (PROVIDE SPLASH GUARDS PER HEALTH) WATER METER 5.00 PSISTATIC HEIGHT 10 FT.x.43 4.30 PSI DS GS <br /> SPLASH GUARDS ADVANCE MODEL NO. 7-PS-66 PROVIDE WITH 0.5 GPM PRESSURE PIPE LOSS H LBS/T.x.43 6.00 PSI <br /> STAINLESS STEEL COMPENSATING AERATOR. THIS SHEET CONTAINS: <br /> NOTE: APPROXIMATELY 100 EQUIVALENT FEET OF PIPING TO EXISTING GENERAL. NOTES: <br /> CAST IRON BODY, 6" DIAMETER NICKEL LANDLORD PROVIDED REMOTE COLD WATER METER SERVICE FLOOR PLAN <br /> FLOOR BRONZE "TYPE B STRAINER, COMBINATION 1 . WELDING OR DRILLING OF STRUCTURAL MEMBERS IS NOT ALLOWED. PLUMBING WORK <br /> FD DRAIN W/ ZURN 2415 "B" - 2 2 - - INVERTIBLE MEMBRANE CLAMP AND TOTAL LOSSES 15.3 PSI 2. DO NOT RUN PIPING THRU, OVER OR UNDER ELECTRICAL EQUIPMENT AREA. PROVIDE <br /> TRAP ADJUSTABLE COVER. PROVIDE WITH TRAP CLEARANCE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE. <br /> PRIMER PRIMER TAP AND TRAP PRIMER. <br /> 3. PROVIDE SHUT-OFF VALVE INCOMING COLD WATER LINE AT PLUS 60" IN WING WALL <br /> ADJACENT TO 3 COMPARTMENT SINK WITH APPROVED ACCESS PANEL. <br /> TP-1 TRAP PRIMER P1 -500 W/ADAPTER _ _ _ 1/2" - INTEGRAL BFP AND VACUUM BREAKER 4. ALL PIPING SHALL BE CONCEALED. SURFACE MOUNTED PIPING IS NOT ALLOWED. <br /> / MOUNT ABOVE CEILING 2019 CALG R EEN COMPLIANCE NOTES: <br /> SQUARE POLISHED BRONZE ACCESS 5. PLUMBING CONTRACTOR SHALL COORDINATE WITH ARCHITECTURAL FOR EXACT FIXTURE <br /> W <br /> WCO WALL CLEAN OUT ZURN MODEL #ZB-1443 - - - - - / LOCATION PRIOR TO ANY SAW CUTTING OR PLUMBING INSTALLATION. <br /> COVER AND FRAME. <br /> BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH SECTIONS 701 .0 6. REMOVE ALL UNUSED PLUMBING FIXTURES, ACCESSORIES AND PIPING. DO NOT ABANDON. <br /> AND 903.0 OF THE 2019 CALIFORNIA PLUMBING CODE. <br /> FCO CLEANOUT ZURN MODEL ZN-1400 _ SEE PLAN _ _ _ EXTRA HEAVY DUTY ADJUSTABLE FLOOR 7. ALL IN-FLOOR MOUNTED FIXTURES ARE TO BE MOUNTED FLUSH WITH FLOOR. <br /> (ADJUSTABLE) FOR SIZE CLEANOUT WITH NICKEL BRONZE TOP ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN APPROVED LISTED AGENCY. <br /> 8. PLUMBING WORK SHALL CONSIST OF FURNISHING AND INSTALLING ALL LABOR, MATERIALS <br /> PLUMBING FIXTURES SHALL MEET THE MAXIMUM FLOW RATES PER SECTION 5.303.3 AND EQUIPMENT TO COMPLETE ALL PLUMBING WORK SHOWN ON THE DRAWINGS AND/OR <br /> 1/2" INLET/OUTLET, OF THE 2019 CALIFORNIA GREEN BUILDING STANDARD CODE. SPECIFIED. <br /> THERMOSTATIC ZURN MODEL LFMMV _ _ _ " _ SET SUPPLY TEMP. AT 110` F. <br /> TMV-1 MIXING VALVE (OR APPROVED EQUAL) 1/2 (PROVIDE WITH ALL HAND SINKS/LAVATORIES). PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE 9. INSTALL CLEAN-OUTS AT ALL BENDS, ANGLES AND ENDS OF ALL WASTE LINES AND ABOVE <br /> CALIFORNIA PLUMBING CODE AND SHALL MEET THE APPLICABLE STANDARDS ALL CONNECTIONS IN WALLS OF SINK WASTE LINES. INSTALL ALL ABOVE 6" COVE BASE. <br /> REFERENCED IN TABLE 1701.1 OF THE CALIFORNIA PLUMBING CODE AND IN P 1 <br /> NOTE: ALL PLUMBING FIXTURES AND ACCESSORIES ARE TO BE SUPPLIED & INSTALLED BY CONTRACTOR. CHAPTER 6 OF THE CALIFORNIA GREEN BUILDING STANDARD CODE. 10. ALL TRAPS, HOT WATER PIPES AND DRAIN PIPES SHALL BE INSULATED OR COVERED, BELOW <br /> LAVATORIES AS PER CODE. <br /> ARCHITECT'S COMMISSION NUMBER <br /> 20 - 1010 . 005 <br />