Laserfiche WebLink
N . E. C. HAZARDOUS AREA NOTES <br /> REMOTE VENT AND CLEAN AIR <br /> SEPARATOR LOCATIONS WILL <br /> VARY WITH TANK LOCATION, <br /> SEE SITE SPECIFIC DRAWINGS N.E.C.ARTICLE 514 CLASS 1 LOCATION <8> <br /> D TYPICAL N.E.C.ARTICLE 514 CLASS 1 LOCATION <br /> OTYPICAL(UNDERGROUND TANK-FILL OPENING) (DISPENSING DEVICE-PITS) <br /> FOR EXACT TANK LOCATION AND SHEET <br /> G0.1 FOR LOCATION OF CLEAN AIREXTENT OF CLASS 1,GROUP D, DIVISION 1 LOCATION: EXTENT OF CLASS 1,GROUP D, DIVISION 1 LOCATION: <br /> SEPARATOR AND VENT RISERS (TYP.) <br /> ANY PIT,BOX,OR SPACE BELOW GRADE LEVEL,ANY PART OF WHICH IS ANY PIT, BOX,OR SPACE BELOW GRADE LEVEL,ANY PART OF WHICH IS c <br /> WITHIN THE DIVISION 1 OR 2 CLASSIFIED LOCATION. WITHIN THE DIVISION 1 OR 2 CLASSIFICATION LOCATION. O <br /> Q <br /> EXTENT OF CLASS 1,GROUP D,DIVISION 2 LOCATION: O TYPICAL N.E.C.ARTICLE 514 CLASS 1 LOCATION v <br /> UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN A HORIZONTAL RADIUS (DISPENSING DEVICE-DISPENSER) N <br /> CLASS 1, DIV. 1 B OF 10 FEET FROM A LOOSE FILL CONNECTION AND WITHIN A O <br /> 5'RADIAL FROM HORIZONTAL RADIUS OF 5 FEET FROM A TIGHT FILL CONNECTION. EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: <br /> SPACE CLASSIFICATION INSIDE THE DISPENSER ENCLOSURE IS COVERED <br /> VENT OUTLET O TYPICAL N.E.C.ARTICLE 514 CLASS 1 LOCATION IN ANSIIUL 87,"POWER OPERATED DISPENSING DEVICES FOR PETROLEUM <br /> B (UNDERGROUND TANK-VENT DISCHARGING UPWARD) PRODUCTS." <br /> EXTENT OF CLASS 1,GROUP D, DIVISION 1 LOCATION: TYPICAL N.E.C.ARTICLE 514 CLASS 1 LOCATION O <br /> j WITHIN 5 FEET OF OPEN END OF VENT,EXTENDING IN ALL DIRECTIONS. (DISPENSING DEVICE-DISPENSER} <br /> D <br /> EXTENT OF CLASS 1,GROUP D,DIVISION 2 LOCATION: <br /> EXTENT OF CLASS 1,GROUP D, DIVISION 2 LOCATION: <br /> CLASS 1, DIV. 2 B SPACE BETWEEN 5 FEET AND 10 FEET OF OPEN END OF VENT, WITHIN 18 INCHES HORIZONTALLY IN ALL DIRECTIONS EXTENDING TO <br /> 10' RADIAL FROM EXTENDING IN ALL DIRECTIONS. GRADE FROM(1)THE DISPENSER ENCLOSURE OR(2)THAT PORTION OFit <br /> VENT OUTLET THE DISPENSER ENCLOSURE CONTAINING LIQUID HANDLING <br /> OTYPICAL N.E.C,ARTICLE 514 CLASS 1 LOCATION COMPONENTS. SPACE CLASSIFICATION INSIDE THE DISPENSER <br /> C (REMOTE PUMP-OUTDOOR) ENCLOSURE IS COVERED IN ANSI/UL 87, "POWER OPERATED DISPENSING <br /> DEVICES FOR PETROLEUM PRODUCTS." PI"Ot0 08-21-17 <br /> EXTENT OF CLASS 1,GROUP D, DIVISION 1 LOCATION: TYPICAL N.E.C.ARTICLE 514 CLASS 1 LOCATION <br /> ANY PIT,BOX,OR SPACE BELOW GRADE LEVEL IF ANY PART IS WITHIN A O (DkSPENSING DEVICE-OUTDOOR) <br /> HORIZONTAL DISTANCE OF 10 FEET FROM ANY EDGE OF PUMP. <br /> CLASS 1, DIV, 2 EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: EXTENT OF CLASS 1,GROUP D, DIVISION 2 LOCATION: <br /> H 18" RADIAL FROM WITHIN 3 FEET OF ANY EDGE OF PUMP, EXTENDING IN ALL DIRECTION. UP TO 16 INCHES ABOVE GRADE LEVEL WITHIN 20 FEET HORIZONTALLY OF <br /> VAPOR TANK ALSO UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN 10 FEET ANY EDGE OF ENCLOSURE. co <br /> HORIZONTALLY FROM ANY EDGE OF PUMP. <br /> CLASS 1, DIV. 2 10' O TYPICAL N.E.C.ARTICLE 514 CLASS 2 LOCATION c <br /> H PERIMETER FROM (VAPOR PROCESSING SYSTEM) <br /> VAPOR TANK EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: X U) <br /> N <br /> UP TO 18 INCHES OF EQUIPMENT EXTENDING HORIZONTALLY IN ALL W W <br /> .. A DIRECTIONS OF ANY EDGE OF EQUIPMENT DOWN TO GRADE LEVEL. UP TO W O <br /> i 18 INCHES ABOVE GRADE LEVEL WITHIN 10 FEET HORIZONTALLY OF ANY <br /> EDGE OF EQUIPMENT. ZZ O > Lo <br /> Q <br /> 10'-0" <br /> - - > N � rn ❑ <br /> 8. p CLASS 1, DIV. 1. TYPICAL, LLL <br /> W ❑ zzZ <br /> SUMP UNDER VENT RISER � O W � Q U) <br /> W > © F- ,`t.,,l <br /> W <br /> W JIcNoo U <br /> N . E . C . CLASSIEIED AREA VAPOR SYSTEM C) �., � w <br /> 4 1,8» - 1' <br /> @ z <br /> 0 <br /> 0 <br /> N <br /> C1r) <br /> A CLASS 1, DIV. 2 <br /> _ ..._. .._ ..-...w._. -..__. _..._ ._-..__ M (TYP. 3) <br /> - A CLASS 1, DIV. 1 <br /> I�f�LL`7C�W ww.._..........__._......__a._w__...._...._.._..._...._..._..µ...._..�m-_..........._........_._..._......mmmP___n.�a___M....,) <br /> (TYP. 3) <br /> �9 <br /> V-6" C CLASS 1, DIV. 1 <br /> (TYP. 3) <br /> 77 <br /> GLASS 1 DIV. 2 F <br /> C CLASS 1, DIV. 2 a��m <br /> 10' RADIAL <br /> (TYP.) c� / <br /> ti (D <br /> (TYP. 3) <br /> E CLASS 1, DIV. 1 R141_d" <br /> I., ) <br /> (TYP.) <br /> G CLASS 1, DIV.2 O <br /> „ V <br /> ' RADIAL (TYP.) CLASS 1, DIV. C <br /> ' (TYP. 3) <br /> �y <br /> CLASS 1, DIV. 1 A <br /> 20'-0" (TYP. 3) <br /> .o <br /> D CLASS 1, DIV. 1. TYPICAL, <br /> SUMPS UNDER DISPENSERS <br /> (TYP.) �i <br /> h Q1 co <br /> O � Q <br /> END E �EVATIOI� ° <br /> o <br /> LL <br /> R20'-0" R201_0, <br /> ❑i 0 Lu C7 >D ° <br /> ~ © <br /> CLASS 1, DIV. 2 U U <br /> (TYP.) F 00 Z� <br /> CLASS 1, DIV, 1 0 <br /> (TYP) E N Q <br /> _ __ m . .._. ..._m_--_... ❑ Cp <br /> R2o' 011 U) D <br /> ° <br /> ° o L) c -c <br /> a U1 ❑ ❑ U <br /> v <br /> s[7 <br /> rn FIT " O UOOp C +�(� O <br /> �, pQ7 {4 fi3 ° OmC <br /> C) y mow- �y G v O U O <br /> `p �.0, c: <br /> N.^L C o .O 0Q3 C ° L <br /> C].0 O.-. ° O C � 6,2to (ll <br /> _O ?i='� ° O W� 0-0 to N <br /> 1 1-611 �co U 7 O p U).0 3 -O <br /> (D-0 ""`� O <br /> rn <br /> En 0 <br /> CLASS 1, DIV. 2 FM fn <br /> Z-4> <br /> E <br /> CLASS 1, DIV. 1 6z ° ° ° p E <br /> a TYP. (TYP.) f U W- (n u (a ca <br /> (TYP.) �°?o=-0.6- ° � t�noccnU <br /> ❑� ou°ic° i° nXiU •E <br /> G CLASS 1, DIV, 2 <br /> 20' RADIAL(TYP) <br /> PROFESS/Q <br /> rn <br /> N . E . C . CLASS EIED AREA GROUND LEVEL a <br /> w y <br /> � <br /> 1/8;t = 1,_�» <br /> 18457 <br /> C <br /> Li <br /> N <br /> � CSP n <br /> 4O <br /> 2 CV <br /> i!e <br /> SIDE ELEVATION SHEET: <br /> 2 1�4„ 1'-0" <br /> G9 . 1 <br /> FUELING - USA <br /> if <br /> � <br />