My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0082859_SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
ROBERTS
>
8744
>
2600 - Land Use Program
>
SR0082859_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2020 10:28:51 AM
Creation date
12/16/2020 9:48:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0082859
PE
2602
STREET_NUMBER
8744
Direction
S
STREET_NAME
ROBERTS
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16210003
ENTERED_DATE
11/9/2020 12:00:00 AM
SITE_LOCATION
8744 S ROBERTS RD
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Percolation Test Results <br /> The completed percolation test form is included in Appendix 3 of this report. The form <br /> was signed by Ms. Afonskaia and indicates a percolation rate for the hole based on the <br /> least water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br /> or equal to 60 min/in drop. For the Site to utilize a standard septic system, one <br /> percolation test must demonstrate a satisfactory percolation rate within the proposed <br /> septic system disposal field. Details and results of the percolation testing are <br /> summarized in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> P1, <br /> 5/11/2020 3.08 5.43 4 hr. Satisfactor�r perc. <br /> Shallow Test rate <br /> Note: A satisfactory percolation rate for a "shallow" test is greater than 1 but less than or equal to 60 minutes per <br /> inch. <br /> 1 Per San Joaquin County Environmental Health Department, a rate between 5.0 and 30.0 min/in requires an <br /> eight-foot separation between the bottom of dispersal system and ground water, or mitigation by system <br /> design or enhancement. <br /> Discussion of Percolation Test Results <br /> The soils near the existing septic system on the Site have demonstrated a satisfactory <br /> percolation rate for the use of a standard septic system in accordance with the <br /> requirements of the San Joaquin County Environmental Health Department. <br /> Because of the percolation rates between 5.0 and 30.0 min/in encountered in the test <br /> holes, the San Joaquin County Environmental Health Department will require an eight- <br /> foot separation from the bottom of the dispersal system to ground water. Ground water <br /> is anticipated to be encountered approximately 15 feet below ground surface at the Site. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines or a filter bed should follow the San <br /> Joaquin County On-Site Wastewater Treatment Systems Standards (2017) where <br /> applicable. No construction is anticipated. <br /> LOGE 20-17 Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.