Laserfiche WebLink
J <br /> San Joaquin County <br /> OPgIJI" C Environmental Health Department DIRECTOR <br /> �•'_�� `P p Donna Heran,REHS <br /> 1868 East Hazelton Avenue <br /> PROGRAM COORDINATORS <br /> Stockton, California 95205-6232 Robert McClellon,REHS <br /> -- Jeff Camiesco,REHS,RDI <br /> Kasey Foley,REHS <br /> CIFORd Website: wwwsjgov.org/ehd Linda Turkatte,REHS <br /> Phone: (209) 4683420 <br /> May 24, 2012 Fax: (209) 464.0138 <br /> Ahmad Ghaderi <br /> A&S Engineering <br /> 28405 Sand Canyon Rd. <br /> Canyon Country, CA 91387 <br /> Re: Tesoro/USA#68150 13975 E. Hwy 88 Lockeford, CA 95237 SR0064416 <br /> The San Joaquin County Environmental Health Department(EHD) has reviewed the permit <br /> application for a new installation of an underground storage tank(UST)system at the above <br /> noted address. In order for this permit application review to continue, a detailed addendum and <br /> revised sheets for plans must be provided for the following deficiencies: <br /> 1. The site plan sheet TK1-1 General Notes#15 lists "New Advanced Containment Deep <br /> Under Dispenser Containment Sumps". It should list S. Bravo Under Dispenser <br /> Containment Sumps. Sm RE,/. Pt-not <br /> 2. The site plan sheet TK2-1 Equipment list: SV:,F K•EY • Pt—AIA <br /> ✓19H should have quantity of 3 fill containers. <br /> �20C should have quantity of 2 vapor containers. <br /> 22 should have quantity of 3 turbine sumps. <br /> ✓23B should have quantity of 3 fill sumps. <br /> . 4 should say S. Bravo and model#. <br /> �0 should say model#B8000 due to conversion order and cut sheet. <br /> ✓�8 should say model 101 for gas and model 111 for diesel. <br /> 92 should say model 304 for sump and under dispenser interstitial. <br /> 3. The site plan sheet TK2-3 General Notes#16 overfill alarm should be programmed at <br /> 90%. SEECTEV. FILM <br /> 4. The site plan TK3-3 Section D label between 72 and 67 lists gasoline float. It should list <br /> diesel float. .Tm Rre - FI-M <br /> 5. The site plan TK4-1 Section A, D, & E lists "Advanced Containment". It should list S. <br /> Bravo Containment. SEF- jzr-y . PLAN <br /> 6. The site plan TK4-2 Section A& E lists"Advanced Containment". It should list S. Bravo <br /> Containment. SFE may. PLM <br /> 7. The site plan TK5-3: S''uf—= RF—V - P►-,4A <br /> Section A, B, & C lists °Advanced Containment". It should list S. Bravo Containment. <br /> Section A, B, & C list#58 hydrostatic sensor. It should list#92. <br />