Laserfiche WebLink
BUILDING <br />AND SAFETY <br />CONSTRUCTION <br />1. Entrance door to be self-closing. <br />2. All compressor units shall be separated from food preparation and food storage areas while being made accessible from the outside. <br />3. All doors should close tightly and all openings in or around pipes, floors and walls are to be tightly sealed and secured from rodents. <br />4. Sinks are to be constructed of stainless steel metal with mixed hot/cold faucets. Must include stainless steel drain boards with a slope 0.125" (1 /8") per foot. <br />4.1 All food contact surfaces, counter tops, food compartments, walls and ceilings are stainless steel 304 #4 grade. <br />5. Must include a single service soap and towel dispenser. <br />6. Floor surface is to be impervious, smooth and easy to clean. Should provide employee safety from slipping. <br />7. All equipment to be easily cleanable without channels or crevices. there must not be exposed threads, nuts, or rivets that may interfere with proper cleaning of equipment. insulation below <br />griddle is to be completely covered and unexposed. <br />8. All construction joints and weld seams to be sealed, smooth, and cleanable. <br />9. Floor mounted equipment to be sealed to the floor or elevated at least 6" off the floor on clean, round, metal legs. <br />10. All equipment to be sealed together or spaced a minimum of 4" apart from each other. <br />11. An accurate thermometer is to be provided in all refrigeration units. <br />12. All light bulbs and tubes to be enclosed in plastic. <br />13. All serving openings are to be equipped with self-closing solid windows or screens. <br />14. Water heater shall be capable of providing hot water to the sink at a minimum of 6 gallons' capacity. An instantaneous water heater should be capable of producing water at 120 f. <br />15. Floor covering material shall extend up the sides of the walls a minimum of 4". <br />16. Wall and ceiling surface should be durable, impervious, smooth and easily cleanable. <br />17. Each service window opening shall be limited to 216 sq. inches. a minimum distance of 18" must be maintained between each opening. <br />18. The minimum ceiling height is 76" high. <br />19. Aisles are to be a minimum of 30" wide and 76" in height. <br />20. Walls and ceiling are to have a stainless steel metal finish. <br />21. Floor finish shall be of diamond plate aluminum. <br />22. Ceiling vent screen mesh shall be a minimum of 16 -mesh per square inch. <br />23. The vertical distance between the lip of hood and the cooking surface shall not exceed four feet. <br />CAL CENTRAL CATERING TRAILER <br />3511 Finch Rd. #A <br />MODESTO CA 95357 <br />(866) 549-1550 <br />For: Project Number <br />Mauricio & Leticia Correa i 13931611136 <br />MODEL: TRL16-8.5 [SATE: 02/07/2017 <br />sHEET 2 1177 Design by: Jesus Estrada <br />Email: jestrada@calcentral.us <br />