Laserfiche WebLink
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for TOKAY SHELL as of September30 , 2021 . <br /> Open violations from April 21, 2021 inspection <br /> ❑ This violation was corrected ❑ This violation will be corrected by ( date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #208 - Failure to comply with the designated operator inspection requirements . <br /> OBSERVATION: The designated operator failed to check and note all required items on the visual inspection <br /> reports . The incorrect and missing information included the following from the inspection reports : <br /> -05/2020 through 10/2020 reports were missing the spill container test date <br /> -05/2020 through 10/2020 reports did not answer questions regarding overfill prevention and secondary containment <br /> testing <br /> -02/2021 through 04/2021 had the incorrect monitoring system certification and spill container test dates <br /> -the 02/04/2021 report did not address the L14 (annular) and L15 ( high limit) alarms on 01 /08/2021 <br /> REGULATION GUIDANCE: During the visual inspection , the designated operator shall check that all required <br /> testing and maintenance for the UST system have been completed and shall check all required items on the report. <br /> CORRECTIVE ACTION : Ensure that designated operators performing visual inspections at this facility are including <br /> all of the required information on the reports . <br /> OBSERVATION: Designated operator reports were not signed within the required time frame . The 05/2020 through <br /> 04/2021 reports were not signed and dated by the owner/operator <br /> REGULATORY GUIDANCE: Within 48 hours of the completion of the designated UST operator visual inspection , <br /> the designated operator shall sign and provide the owner or operator with a copy of the inspection report. Within 72 <br /> hours of being provided a signed copy of the report, the owner or operator shall provide a description of each <br /> corrective action taken or to be taken and shall sign and date the report, acknowledging the identified compliance <br /> issues . <br /> CORRECTIVE ACTION : Ensure all designated operator inspection reports are completed and signed within the <br /> required time frame in the future . <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Page 4 of 5 <br />