Laserfiche WebLink
San Joaquin Valley HEALTHY AIR LIVING' <br /> www,he Ithyairlivingxarn <br /> AIR POLLUTION CONTROL DISTRICT Make one change for clean air! <br /> TP 201.3 <br /> UST Static Pressure Performance Test Report Form <br /> Permit Number:N-3810 Test Company:Tanknology Inc. <br /> Site Name: 7-ELEVEN#32190, MKT 2368 Technician:Tim Elebeck <br /> Site Address:4943 S.KINGSLEY(FRONTAGE RD)HWY 99 @ ARCH Certification Number Expiration Date <br /> AIRPORT RD <br /> City: STOCKTON zip: 95206 District: <br /> Date/Time of Test:10/15/2018/ <br /> TEST INFORMATION <br /> Total number of nozzles: Are the tanks manifolded?F10': Yes F'No <br /> Phase I vapor recovery system executive order(as referenced on Permit to Operate) VR 102 <br /> Phase II vapor recovery system executive order(as referenced on Permit to Operate) VR 202 <br /> Nitrogen introduction point F Phase I Vapor Coupler P Phase II Vapor Riser <br /> Pressure measuring device F Incline Manometer F Digital Manometer F Mechanical Gauge <br /> Calibration date for pressure measuring device(must be within 90 days of the test) 9/5/2018 <br /> Ending value for digital manometer drift test if applicable(must be 0.01 in.w.c.or less) 0.00 <br /> Initial tank ullage pressure(vent if over 0.5 in w.c.) -5.87 <br /> Nitrogen introduction flow rate, F(must be between 1 and 5 CFM) 2.00 <br /> Calculated ullage fill-time,t2 02=V/1522 x F) 03:36 <br /> Actual fill-time <br /> Number of hoses with over 100 ml(balance hoses must be drained prior to testing) <br /> TANK INFORMATION <br /> Tank No. 4 5 6 ALL <br /> Product grade 87 89 91 <br /> Actual tank capacity(gallons) 14752 9684 9684 34120 <br /> Gasoline volume(gallons) 9344 7288 6533 23165 <br /> Ullage,V(gallons) 5408 2396 3151 10955 <br /> If tanks are not manifolded, number of nozzles 0 <br /> 2 IN.W.C.STATIC PRESSURE TEST <br /> Test No. 1 2 3 5 <br /> Start time 10:30:00 <br /> Initial Pressure,inches of water column(in.w.c.) 2.00 <br /> Pressure at one minute, in.w.c. 2.00 <br /> Pressure at two minutes, in.w.c. 2.00 <br /> Pressure at three minutes,in.w.c. 1.99 <br /> Pressure at four minutes,in.w.c. 1.98 <br /> Pressure at five minutes,in.w.c. 1.98 <br /> Allowable minimum pressure, in.w.c. 1.90 <br /> Pass/Fail(enter"GF"for gross failure) Pass <br /> 1 declare, under penalty of perjury under the laws of the state of California that based on information and belief formed after reasonable inquiry, the <br /> statements and information provided in the document are true, accurate,and complete. <br /> Signature of Technician: �� @ k Date: 10/15/2018 <br /> WO:2338552 Ver. 1.0—12.26.07 <br />