My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1405
>
2300 - Underground Storage Tank Program
>
PR0231485
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2021 11:59:17 AM
Creation date
1/25/2021 4:18:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231485
PE
2361
FACILITY_ID
FA0000306
FACILITY_NAME
EMILS LIQUOR & SPORTS SHOP*
STREET_NUMBER
1405
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
ESCALON
Zip
95320
APN
22707031
CURRENT_STATUS
01
SITE_LOCATION
1405 CALIFORNIA ST
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7/9/2021 647555353 .jpg <br /> UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> ; i, IIIIIType of Action T _ ❑ Installation Inspection ❑ Repair Inspection ❑x 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID Unla of Overfill PfevenNon Equipment Inspection <br /> 101805G7 8/23/ 1 <br /> Business Name (Same as Facility Alamo or DBA-Doing Business As) - - <br /> EMILS LIQUOR <br /> Business Site Address City ZIP Code <br /> 1405 CALIFORNIA ST _ _ ESCALON 95320 <br /> il . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as sho:vn on the ICC Certification) Phone # <br /> Edward Stearns (209) 744 -0112 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Dare <br /> 14 - 1760 Ex . 09/30/2020 8883080-UT 11 /912020 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable codifications.) i <br /> FF- EBW , Phil-Tite & EVR Phase 1 1009893708 Ex 11 /29/2020 OPW 104-635 Ex 3-14-2020 r. <br /> Emco 3205 Ex. 11 / 16/2020 ATG : VR A31048 Ex.8/9/19 Incon 1009893708 11 /30/2_020 <br /> lilt OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspedion Melhod 21 Manufacturer Guidelines (Specih): <br /> Used: REMOVE AND INSPECT OPW <br /> i <br /> ❑ Industry Code or Engineering Standard (Specify): <br /> ❑ Engineered Method (Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. # of Affached Pages 2 i <br /> TANK ID: (By tank number, stored product, etc) DIESEL <br /> Mat is the tank inside diameter? (inches) 128 <br /> is the fill piping secondarily contained? ❑ Yes Q No ❑ Yes ❑ No ❑ 'res ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained? ❑ Yes R) No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Overfill Prevention Equipment Manufacturers) _ OPW_ <br /> 71S0 <br /> 'mat is the overfill prevention equipment response ❑x Shuts Oft Flow ❑ Shhds Off Flow ❑ Shuts Off F(o• v ❑ Shuts Off Flow <br /> tI when activated? ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flocr <br /> (Check all that apply,) <br /> j DAN Alarm ❑ AN Alarm ❑ AN Alarm ❑ AN Alarm <br /> Are flow restdctors if, on vent piping? ❑ Yes d No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ' <br /> At what level in the lank is the overfill prevention set 115 <br /> to activate? (Inches from bottom of tank ) 3 <br /> What is the percent capacity of the tank at which the <br /> 94 * 8 <br /> overfill prevention equipment aaivates ? <br /> Is the overfill ptoventionin proper opoialing condition t] Yes ❑ Yes ❑ Yes ❑ Yes f i <br /> to respond when the substance leeches the <br /> appropriate level? ❑ No (Specify in V) ❑ No (Spa ciyin V.) ❑ No (Specify In V.) ❑ No (SpecilyIn V.) Y ; <br /> We SUMMARY OF INSPECTION RESULTS r `' <br /> Overfill Prevention Inspection Resrdts Ex1 Pass El Fall Li Pass U. [] Prix ❑ Fal ❑ Pass Q Fall W11 <br /> V. COMMENTS <br /> Any darns marked 'Fail" must be explaiaad in this section. Any additional comments bray also be provided here. .: <br /> l <br /> VI. CERTIFICATION BY UST 'SERVICE TECHNICIAN CONDUCTING THIS INSPECTION _ <br /> I hereby certify thatthe ovorf lit prevention equipment was inspected In accordancowilh California Code of Roguladons , Title 23, <br /> Division 3, Chapter 16, Socfion 2637.2 and all the Information coAtainod heroin is accurate. <br /> ' — <br /> UST Service Technician signature <br /> If ftia radfity has morn components than this ronn acconmrodatest additional eoptes of thio pajo rnnyba attached. <br /> CURS = CW0TVa UnWar'mcnu Repoil�hg Syafent ID = Iden 6catat UST ' Dnda6`ixxxt SiaaW Ta* ICC In �Ynito aI Code Council. M! = P die and Vo sdLq <br /> It <br /> 14 <br /> 44 <br /> 'milt I't <br /> c <br /> littps ://niail .google.com/niail/u/O/? tab= km#inbox?projector= 1 1 / 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.