My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1405
>
2300 - Underground Storage Tank Program
>
PR0231485
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2021 11:59:17 AM
Creation date
1/25/2021 4:18:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231485
PE
2361
FACILITY_ID
FA0000306
FACILITY_NAME
EMILS LIQUOR & SPORTS SHOP*
STREET_NUMBER
1405
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
ESCALON
Zip
95320
APN
22707031
CURRENT_STATUS
01
SITE_LOCATION
1405 CALIFORNIA ST
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN Environmental Health Department <br /> - - c �� �� ;v - .,. _ _ <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date : <br /> EMILS LIQUOR & SPORTS SHOP ` 1405 CALIFORNIA ST , ESCALON May 29 , 2019 <br /> File Review <br /> 123 CCR 2637 . 1 (d ) . Failure to submit the "Spill Container Testing Report Form" within 30 days after the lest a V o R D COS <br /> 2637 . 1 (e) <br /> 124 CCR 2637 .2(d& e) , "Overfill Prevention Equipment Inspection Report Form" not submitted within 30 days of Inspection o V u R D COS <br /> 2665(a &b) <br /> On Site Records <br /> 201 CCR 2712(b) Failure to maintain monitoring , maintenance, and follow up action records a V u R o COS <br /> 202 CCR 2715(c)(3) , Failure to maintain the "Facility Employee Training Certificate" on-site (after October 1 , 2018 ) a V n R D COS <br /> 2715(c)(4) <br /> 203 CCR 2712(b) Failure to maintain records of repairs, lining , and upgrades on site, for the life of the UST D V o R o COS <br /> 204 CCR 2712(1 ) Current monitoring plan approved by the EHD not found on site n V o R o COS <br /> 205 CCR 2712(1), 2634 (e) Failure to submit a current UST Response Plan and have it available onsite in V a R o COS <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions a V D R D COS <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment D V o R o COS <br /> 208 CCR 2650(e), 2652 Failed to notify the EHD of a reportable unauthorized release and/or prepare a report D V D R u COS <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days o V D R D COS <br /> 210 CCR 2716(() DO monthly reports not maintained on site for 12 months or for 36 months (after October 1 , 2018) o V D R D COS <br /> 211 CCR 2715(c)(2 ) No employee present that were trained in the operation and maintenance of the UST system by a DO n V o R u COS <br /> 212 CCR 2715 (f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD D V o R D COS <br /> 213 HSC 25281 ,5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept D V a R o COS <br /> 214 HSC 25281 .5(b)(3) Unburied emergency generator fuel piping not visually Inspected at least monthly or log kept o V a R D COS <br /> 215 CCR 2712(i ) Failure to retain a copy of the permit to operate at the facility D V o R D COS <br /> UST System Observations <br /> 301 NSC 25292 . 1 (a ) UST system is not operated to prevent unauthorized release , including spills and overfills a V u R COS <br /> 302 HSC 25291 (b) UST system Incapable of detecting leak from primary into secondary containment (pre-Jul 2003) D V D R u COS <br /> 303 HSC 25290 .2 (d ) Monitoring system not maintained to detect entry into secondary containment (Jul 2003-Jun 2004) D V u R o COS <br /> 304 HSC 25290 . 1 (d ) Monitoring system not maintained to detect entry into secondary containment (after Jul 2004) D V n R D COS <br /> r3O7 <br /> HSC 25290 . 1 (e) VPH monitoring of the Interstitial spaces of the UST system is not maintained u V o R D COS <br /> CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity o V D R D COS <br /> CCR 2631 (g ), 2632(c) Monitoring system of the interstitial space of a double walled system not maintained a V o R c COS <br /> CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm o V n R D COS <br /> 309 CCR 2636(f)( 1 ) Monitoring in sump 1 UDC failed to activate an audible and visual alarm or stop the pow product o V c R z COS <br /> 310 CCR 2636(f)(4) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser Inside UDCs n V a R D COS <br /> 311 CCR 2638(a), 26410) Failed to properly program , calibrate, operate , or maintain leak detection equipment D V D R D COS <br /> 312 CCR 2638((), 2641 (1) Failed to affix a tag sticker on monitoring equipment certified, repaired, or replaced D V o R o COS <br /> 313 HSC 25290 . 11 25290. 2, Failure to construct, operate , and maintain primary containment as product-tight n V n R D COS <br /> 25291 <br /> FA0000306 PR0231485 SCO01 05/29/2019 <br /> EHD 23-01 Rev. 09/28/2018 Page 2 of 4 Underground Storage Tank Program OR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464 -0138 1 www . sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.