Laserfiche WebLink
P W--t� <br />aJ= company <br />Uverfill <br />Prevention and Venting Equ0 JER tIRONMENTAL HEALTH <br />DEPARTMENT <br />7150 Testable Overfill Valve <br />The OPW new patent pending Testable 71 SO T Overfill Prevention Valve is the easiest, <br />quickest and most cost efficient way to ensure that your overfill valves will operate <br />when called upon - verifiable without removing them from the tanks. The OPW <br />71 SO -T Testable Overfill Prevention Valve is the only UST Overfill Prevention Valve <br />that is testable from the surface without removal from the tank. <br />6150 &(1150 Overfill Prevention Valves <br />The OPW 6i'SO,and 71 SO vapor -tight Overfil��e�ntion Valves are two-stage <br />shut-off valves designed to prevent the overfill of underground storage tanks by <br />providing a positive shut-off of product delivery. Models of the 61 SO and 71 SO are <br />available to meet virtually any UST application, including two-point, coaxial, poppeted <br />coaxial and remote fill. The 71 SO vapor -tight model is designed for enhanced vapor <br />recovery (EVR) applications. Both the 61 SO and 71 SO are designed for use on tight -fill <br />gravity drop applications only, and can be installed in the fill riser of both new and <br />existing underground storage tanks. <br />Ball Float Vent Valves and Extractor Fittings <br />OPW Ball Float Vent Valves protrude into underground storage tanks from the <br />Stage I vapor return riser pipe. As the tank becomes full during a product drop, the <br />all seats — restricting the flow of vapors back to the transport truck or through <br />the tank vent. As the vapors are compressed in the tank, product flow into the tank <br />is severely restricted. <br />OPW ball floats are mounted in OPW extractor fittings to maintain access through <br />grade level manholes. <br />Drop Tubes and Accessories <br />OPW drop tubes are installed inside tank fill risers to prevent fuel from contacting riser <br />joints. Drop tubes extend close to the bottom of the tank to minimize turbulence and <br />vapor production. Tank bottom protectors are installed on the bottom of drop tubes to <br />prevent tank erosion at the fill point. <br />Pressure Vacuum Vents and Adaptors <br />Pressure Vacuum Vents are installed on the top of vent pipes from underground or <br />aboveground fuel storage tanks. The vent cap and internal wire screen are designed <br />to protect the tank vent lines against intrusion and blockage from water, debris or <br />insects. A normally closed poppet in the valve opens at a predetermined pressure or <br />vacuum setting to allow the tank to vent. <br />11�p',�� 9393 Princeton•Glentlale Road •- Hamilton, Ohio USA 45011 Phone: (800) 42Z-2525 Fax: (800) 421-3297 <br />