METAL SUSPENSION SYSTEMS FOR LAY -IN <br />PANEL CEILINGS <br />1. 12 GA. (MIN.) HANGER WIRES MAY BE USED <br />FOR UP TO AND INCLUDING 4'-0' X 4'-0' GRID <br />SPACING ALONG MAIN RUNNERS. SPLICES <br />WILL NOT BE PERMITTED IN ANY HANGER <br />WIRES UNLESS SPECIFICALLY APPROVED BY <br />DSA/SSS. <br />2. PROVIDE 12 GA. HANGER WIRES AT THE ENDS <br />OF ALL MAIN AND CROSS RUNNERS WITHIN 8" <br />FROM THE SUPPORT OR WITHIN 1 /4" OF THE <br />LENGTH OF THE END TEE, WHICHEVER IS LEAST, <br />FOR THE PERIMETER OF THE CEILING AREA. <br />3. PROVIDE TRAPEZE OR OTHER SUPPLEMENTARY <br />SUPPORT MEMBER AT OBSTRUCTIONS TO MAIN <br />HANGER SPACING. PROVIDE ADDITIONAL <br />HANGERS, STRUTS OR BRACES AS REQUIRED <br />AT ALL CEILING BREAKS, SOFFITS, OR <br />DISCONTINUOUS AREAS. HANGER WIRES THAT <br />ARE MORE THAN I IN 6 OUT OF PLUMB TO <br />HAVE COUNTER -SLOPING WIRES. <br />4. CEILING GRID MEMBERS MAY BE ATTACHED <br />TO NOT MORE THAN 2 ADJACENT WALLS. <br />CEILING GRID MEMBERS SHOULD BE AT LEAST <br />3/4" INCH FREE OF OTHER WALLS. IF WALLS <br />RUN DIAGONALLY TO CEILING GRID SYSTEM <br />RUNNERS, ONE END OF MAIN AND CROSS <br />RUNNER SHOULD BE FREE AND A MINIMUM OF <br />I/2" CLEAR OF THE WALL. <br />5. AT THE PERIMETER OF THE CEILING AREA <br />WHERE MAIN OR CROSS RUNNERS ARE NOT <br />CONNECTED TO THE ADJACENT WALL, <br />PROVIDE INTERCONNECTION BETWEEN <br />RUNNERS AT THE FREE END TO PREVENT <br />LATERAL SPREADING. A METAL STRUT OR A 16 <br />GA. WIRE WITH POSITIVE MECHANICAL <br />CONNECTION TO THE RUNNER MAY BE USED. <br />WHERE THE PERPENDICULAR DISTANCE FROM <br />THE WALL TO THE FIRST PARALLEL RUNNER IS <br />17' OR LESS, THIS INTERLOCK IS NOT REQUIRED. <br />6. PROVIDE SETS OF FOUR 12 GA. SPLAYED <br />BRACING WIRES ORIENTED 900 FROM EACH <br />OTHER AT NOT MORE THAN 12'-0" X 12'-0' ON <br />CENTER. <br />PROVIDE BRACING WIRES AT LOCATIONS <br />NOT MORE THAN 6'-0' FROM EACH PERIMETER <br />WALL AND AT THE EDGE OF VERTICAL <br />OFFSETS. <br />THE SLOPE OF THESE WIRES SHOULD NOT <br />EXCEED 450 FROM THE PLANE OF THE CEILING <br />AND SHOULD BE TAUT WITHOUT CAUSING THE <br />CEILING TO LIFT. SPLICES IN BRACING WIRES <br />ARE NOT TO BE PERMITTED WITHOUT SPECIAL <br />DSA/SSS APPROVAL. <br />7. FASTEN HANGER WIRES WITH NOT LESS THAN 3 <br />TIGHT TURNS, FASTEN BRACING WIRES WITH 4 <br />TIGHT TURNS, MAKE ALL TIGHT TURNS WITHIN A <br />DISTANCE OF 1 1 /2'. HANGER OR BRACING <br />WIRE ANCHORS TO THE STRUCTURE SHOULD <br />BE INSTALLED IN SUCH A MANNER THAT THE <br />DIRECTION OF THE WIRE ALIGNS AS CLOSELY <br />AS POSSIBLE WITH THE DIRECTION OF THE <br />FORCES ACTING ON THE WIRE. <br />NOTE: WIRE TURNS MADE BY MACHINE WHERE <br />BOTH STRANDS HAVE BEEN DEFORMED OR <br />BENT IN WRAPPING CAN WAIVE THE 1 1/2' <br />REQUIREMENT, BUT THE NUMBER OF TURNS <br />SHOULD BE MAINTAINED, AND BE AS TIGHT <br />AS POSSIBLE. <br />8. SEPARATE ALL CEILING HANGING AND <br />BRACING WIRES AT LEAST 6 INCHES FROM ALL <br />UNBRACED DUCTS, PIPES, CONDUIT, ETC. <br />HVAC DUCTWORK, ELECTRICAL DISTRIBUTION, <br />TELEPHONE SERVICES, COMPUTER CABLE <br />DISTRIBUTION, AND OTHER SERVICES <br />NORMALLY FOUND IN A CEILING SPACE, <br />SHALL BE INDEPENDENTLY SUPPORTED AND <br />APPROPRIATELY BRACED TO ELIMINATE ANY <br />LATERAL FORCE ON THE CEILING MEMBRANE <br />OR BRACING ELEMENTS. <br />9. WHEN DRILL -IN CONCRETE ANCHORS OR <br />SHOT -IN ANCHORS ARE USED IN REINFORCED <br />CONCRETE FOR HANGER WIRES, 1 OUT OF 10 <br />MUST BE FIELD TESTED FOR 200 LBS. OF <br />TENSION. WHEN DRILLED -IN CONCRETE <br />ANCHORS ARE USED FOR BRACING WIRES, I <br />OUT OF 2 MUST BE FIELD TESTED FOR 440 LBS. <br />OF TENSION. SHOT -IN ANCHORS IN <br />CONCRETE ARE NOT PERMITTED FOR <br />BRACING WIRES. IF ANY SHOT -IN OR <br />DRILLED -IN ANCHOR FAILS, ALL ADJACENT <br />ANCHORS MUST BE TESTED. DRILLED -IN OR <br />SHOT -IN ANCHORS MUST BE TESTED. <br />DRILLED -IN OR SHOT -IN ANCHORS REQUIRE <br />SPECIAL DSA/SSS APPROVAL WHEN USED IN <br />PRE -STRESSED CONCRETE. <br />10. ATTACH ALL LIGHT FIXTURES TO THE CEILING <br />GRID RUNNERS TO RESIST A HORIZONTAL <br />FORCE EQUAL TO THE WEIGHT OF THE <br />FIXTURES. <br />ALL RECESSED LIGHTING FIXTURES HAVING A <br />NOMINAL END DIMENSION OF 24" OR <br />GREATER, SHALL BE POSITIVELY ATTACHED TO <br />THE CEILING GRID RUNNER(S) AT THE END OF <br />THE FIXTURE WITH TWO #8 SELF TAPPING TEK <br />SCREWS, EACH SCREW SHALL BE LOCATED <br />WITHIN W OF THE SIDE OF FIXTURE AND <br />ATTACHED THROUGH THE BULB OF THE CEILING <br />GRID RUNNER(S). LIGHT FIXTURES HAVING LESS <br />THAN A NOMINAL 24" END DIMENSION SHALL <br />BE ATTACHED WITH ONE #8 SELF TAPPING <br />TEK SCREW AT THE CENTER OF EACH END OF <br />THE FIXTURE, ATTACHED TO THE BULB OF THE <br />CEILING GRID RUNNER{S). ALL ATTACHMENTS <br />SHALL BE CAPABLE OF LATERALLY SUPPORTING <br />THE WEIGHT OF THE FIXTURE. ALL FIXTURES <br />REGARDLESS OF WEIGHT OR SIZE SHALL HAVE <br />INTERLOCKING CEILING GRID RUNNER(S) ON <br />ALL 4 SIDES OF THE FIXTURE. <br />11. CEILING MOUNTED AIR TERMINALS OR <br />SERVICES SHALL BE POSITIVELY ATTACHED TO <br />THE CEILING SUSPENSION MAIN RUNNERS OR <br />TO CROSS RUNNERS WITH THE SAME <br />CARRYING CAPACITY AS THE MAIN RUNNER. <br />AIR TERMINALS WITH A NOMINAL DIMENSION <br />OF 24" OR LESS SHALL BE POSITIVELY <br />ATTACHED TO THE CEILING GRID RUNNERS) <br />ON AT LEAST TWO OPPOSING SIDES WITH ONE <br />SELF -TAPPING TEK SCREW ON EACH SIDE. EACH <br />SCREW SHALL BE LOCATED IN THE CENTER OF <br />THE AIR TERMINAL AND SHALL BE ATTACHED <br />THROUGH THE BULB OF THE CEILING GRID <br />RUNNER(S). AIR TERMINALS IN EXCESS OF 24" IN <br />LENGTH SHALL BE ATTACHED WITH TWO #8 <br />SELF -TAPPING TEK SCREWS ON EACH END OF <br />DIFFUSER ATTACHED TO THE BULB OF THE <br />CEILING GRID RUNNER(S). ALL ATTACHMENTS <br />SHALL BE CAPABLE OF LATERALLY SUPPORTING <br />THE WEIGHT OF THE AIR TERMINAL. ALL AIR <br />TERMINALS REGARDLESS OF WEIGHT OR SIZE <br />SHALL HAVE INTERLOCKING GRID RUNNER(S) <br />OF ALL 4 SIDES OF THE AIR TERMINAL. <br />O <br />9 <br />z <br />Q <br />12. FLUSH OR RECESSED LIGHT FIXTURES AND AIR <br />TERMINALS OR SERVICE'S WEIGHING LESS THAN <br />56 LBS. MAY BE SUPPORTED DIRECTLY ON THE <br />RUNNERS OF A HEAVY DUTY GRID SYSTEM BUT, <br />IN ADDITION, THEY MUST HAVE A MINIMUM OF <br />TWO 12 GA. SLACK SAFETY WIRES ATTACHED <br />TO THE FIXTURE AT DIAGONAL CORNERS AND <br />ANCHORED TO THE STRUCTURE ABOVE. ALL <br />4-a' X f-9' LIGHT FIXTURES MUST HAVE SLACK <br />SAFETY WIRES AT EACH CORNER. ALL FLUSH OR <br />RECESSED LIGHT FIXTURES AND AIR TERMINALS <br />OR SERVICES WEIGHING 56 LBS. OR MORE <br />MUST BE INDEPENDENTLY SUPPORTED BY NOT <br />LESS THAN 4 TAUT 12 GA. WIRES EACH <br />ATTACHED TO THE FIXTURE AND TO THE <br />STRUCTURE ABOVE REGARDLESS OF THE TYPE <br />OF CEILING GRID SYSTEM USED. <br />THE 4 TAUT 12 GA. WIRES INCLUDING THEIR <br />ATTACHMENT TO THE STRUCTURE ABOVE MUST <br />BE CAPABLE OF SUPPORTING 4 TIMES THE <br />WEIGHT OF THE UNIT. <br />13. ALL FIXTURES AND AIR TERMINALS OR SERVICES <br />SUPPORTED ON INTERMEDIATE DUTY GRID <br />SYSTEMS MUST BE INDEPENDENTLY SUPPORTED <br />BY NOT LESS THAN 4TAUT 12 GA. WIRES EACH <br />ATTACHED TO THE FIXTURE OR TERMINAL AND <br />TO THE STRUCTURE ABOVE. <br />14. SUPPORT SURFACE MOUNTED LIGHT FIXTURES <br />BY AT LEAST TWO POSITIVE DEVICES WHICH <br />SURROUND THE CEILING RUNNER AND WHICH <br />ARE EACH SUPPORTED FROM THE STRUCTURE <br />ABOVE BY A 12 GA. WIRE. SPRING CUPS OR <br />CLAMPS THAT CONNECT ONLY TO THE RUNNER <br />ARE NOT ACCEPTABLE. <br />PROVIDE ADDITIONAL SUPPORTS WHEN LIGHT <br />FIXTURES ARE 8 FEET OR LONGER. <br />15. SUPPORT PENDANT MOUNTED LIGHT FIXTURES <br />DIRECTLY FROM THE STRUCTURE ABOVE WITH 9 <br />GA. HANGER WIRES OR CABLES PASSING <br />THROUGH EACH PENDANT HANGER AND <br />CAPABLE OF SUPPORTING 4 TIMES THE WEIGHT <br />OF THE FIXTURE. SPECIAL DETAILS ARE <br />NECESSARY FOR THIS CONDITION AT THE <br />CEILING GRID. <br />16. CEILING AREAS EXCEEDING 1,000 S.F. SHALL <br />HAVE HORIZONTAL RESTRAINT OF THE CEILING <br />TO THE STRUCTURAL SYSTEM. <br />17. POSITIVE BRACING TO THE STRUCTURE SHALL BE <br />PROVIDED AT CHANGES IN THE CEILING PLANE <br />ELEVATION OR AT DISCONTINUITIES IN THE <br />CEILING GRID SYSTEM. <br />18. ALL SPRINKLER HEADS (DROPS), AND ALL <br />OTHER PENETRATIONS SHALL HAVE 7OVERSIZE <br />TRIM TO ALLOW 1"HORIZONTAL MOVEMENT IN <br />ALL HORIZONTAL DIRECTIONS. <br />19. WHEN A CEILING SYSTEM SPAN BETWEEN <br />PERIMETER WALLS IS GREATER THAN 251N BOTH <br />DIRECTIONS, A MINIMUM WALL ANGLE SIZE OF <br />AT LEAST A TWO INCH (52MM) HORIZ. LEG <br />SHALL BE USED AT THE PERIMETER WALLS AND <br />INTERIOR FULL HEIGHT PARTITIONS. THE FIRST <br />CEILING TILE SHALL MAINTAIN 3 INCH (19MM) <br />CLEAR FROM THE FINISH WALL SURFACE <br />20. WHEN THE DISTANCE BETWEEN THE CEILING <br />SUSPENSION SYSTEM AND THE STRUCTURAL <br />DECK ABOVE EXCEEDS 4 FEET, THE CEILING <br />SYSTEM SHALL BE CONNECTED AND BRACED <br />DIRECTLY TO THE STRUCTURE AT THE MEANS OF <br />EGRESS SERVING AN OCCUPANT LOAD OF 30 <br />OR MORE AND AT LOBBIES ACCESSORY TO <br />GROUP 'WOCCUPANCIES. SPACING OF <br />VERTICAL HANGERS SHALL NOT EXCEED 2 FEET <br />(61 OMM) ON CENTER ALONG THE ENTIRE <br />LENGTH OF THE MEANS OF EGRESS OR LOBBY. <br />21. WITHIN A, E, AND M -OCCUPANCIES, AND <br />FIRE -RATED CORRIDORS, ALL LAY4N PANELS <br />SHALL BE SECURED TO THE SUSPENSION SYSTEM <br />WITH TWO HOLD-DOWN CLIPS MINIMUM FOR <br />EACH TILE WITHIN A 4 FOOT RADIUS OF THE EXIT <br />LIGHTS AND EXIT SIGNS. <br />22. INDEPENDENT SUPPORTS AND BRACES SHALL <br />BE PROVIDED FOR LIGHT FIXTURES FOR EXIT <br />ILLUMINATION. POWER SUPPLY FOR EXIT <br />ILLUMINATION SHALL COMPLY WITH THE <br />REQUIREMENTS OF SECTION 1008 OF THE 2016 <br />CBC <br />23. SEPARATE SUPPORT FROM THE STRUCTURE <br />SHALL BE PROVIDED FOR ALL APPENDAGES <br />SUCH AS LIGHT FIXTURES, AIR DIFFUSERS, EXIT <br />SIGNS AND SIMILAR ELEMENTS. <br />24. CLASSIFICATION OF CEILING GRID IS HEAVY <br />DUTY. COMPONENTS SHALL COMPLY WITH THE <br />FOLLOWING SCHEDULE: <br />MANUFACTURER: RUNNER RUNNER <br />ARMSTRONG 7301 7341 (1) <br />CHICAGO METALLIC 200 1204 (2) <br />DONN CORP. DX26 DX424 (3) <br />FOOTNOTES: <br />(1) FOR 2 X 2 GRID USE 7328 <br />(2) FOR 2 X 2 GRID USE 1226 <br />(3) FOR 2 X 2 GRID USE DX216 <br />25, ANCHORS FOR WALL ANGLES: <br />A. AT METAL STUD WALL 1 1 /8" TYPE'S" BUGLE <br />HEAD DRYWALL SCREW AT 16" O.C. <br />26. MAIN BEAMS AND CROSS TEE INTERSECTIONS <br />AND SPLICES MUST HAVE CONNECTION <br />STRENGTHS OF AT LEAST 180 POUNDS IN <br />COMPRESSION AND TENSIONS. <br />27. CEILINGS EXCEEDING 2,500 SQ FT SHALL HAVE <br />A SEISMIC SEPARATION OR A FULL HEIGHT <br />PARTITION THAT BREAKS THE CEILING UP TO <br />AREA NOT EXCEEDING 2,500 SQ FT. <br />INSTALL BOLT TO SECURE ONE — <br />TUBE TO THE OTHER. TUBES SHALL <br />LAP ONE ANOTHER AT LEAST 4" IN <br />A FULLY EXTENDED POSITION. <br />PIPE SLEEVE INSIDE DIMENSION — <br />SHALL BE SLIGHTLY LARGER <br />THAN THE OUTSIDE DIMENSION <br />OF THE COMPRESSION STRUT <br />3 - TURNS OF WIRE- TYPICAL —i <br />3/4" LAG SCREW <br />STRUCTURE <br />RIGID STEEL TUBING (ADJUSTABLE RESISTANCE <br />STRUT) - SEE SCHEDULE FOR SIZE <br />NO. 12 GA. VERTICAL WIRE HANGER, SECURE TO <br />STRUCTURE PRIOR TO SETTING TUBE. <br />DRILL 3/37 HOLE AND INSTALL BOLT AND <br />LOCKING NUT <br />RIGID STEEL TUBING - NOTCHED AT RUNNER <br />12 GA. GALV. WIRE AT 450 TO STRUCTURE ABOVE <br />MAIN RUNNER <br />COMPRESSION PIPE STRUT <br />SIZE DIAM X WALL THICKNESS <br />L MAX HEIGHT <br />1 /7 x 22 GA <br />3'-0' <br />314'X 22 GA <br />4'-3" <br />1" X 20 GA <br />5'-0' <br />1 114'X 20 GA <br />7-0' <br />1 1 /7 X 20 GA <br />8'-6" <br />7' X 20 GA <br />ill -61 <br />2 112'X 18 GA <br />14'-6" <br />3'X 18 GA <br />17-3' <br />3 1/2'X 16 GA <br />20'-0' <br />4" X 16 GA <br />23'3" <br />3 <br />a <br />NOTES: <br />9 • THESE COMPRESSION STRUTS SHALL BE PLACED 12'40" OC IN BOTH DIRECTIONS WITH THE FIRST <br />z POINT 6'-0" FROM EACH WALL. <br />u • SUSPENDED CEILINGS WHICH REQUIRE A PANELIZED SYSTEM, SHALL BE INSTALLED PER ASTM C635 <br />Q AND CBC SECTION 2506.2.1 <br />1 0) CSOMPRESSION CALE STRUT <br />NO <br />A WOOD JOIST OR RAFTER <br />g AT WOOD JOIST OR <br />RAFTER <br />C AT WOOD JOIST OR BLOCK <br />K 9 GA. STAPLES OR <br />GHOLD "J" NAILS AT EACH WIRE LOOP <br />RAFTER <br />WIRE <br />WIRE <br />JOIST OR RAFTER <br />114- DIA. EYE SCREW WITH FULL THREAD <br />EMBEDMENT (2 1 /7'MIN.) <br />BRACING WIRE <br />3- 1 112- X 9 GA. STAPLES OR <br />3 - STRONGHOLD "J" NAILS AT EACH WIRE LOOP <br />2X BLOCKING WITH 2 -16d COMMON NAILS <br />EACH END <br />FOR BRACING WIRES - 114- CLOSED EYE SCREW <br />THREADS IN DIRECTION OF WIRE - 1 1 /4" MIN.. <br />EMBEDMENT <br />1 /4" DIA. DRILLED HOLE <br />N SADDLE TIE - (SEE DETAIL G) <br />HANGER WIRE <br />NOTE: SOLID BLOCKING REQUIRED <br />FOR EITHER TYPE OF BRACING <br />IBER <br />IE - (SEE DETAIL G) <br />CHORD <br />WIRE <br />WIRE <br />BRACING WIRE PARALLEL TO WOOD TRUSS <br />D TO BOTTOM OF JOIST <br />DO NOT INSERT SCREW EYES INTO SIDE OF <br />MICRO -LAM FLANGE <br />BRACING WIRE <br />�1 MICRO -LAM UPPER FLANGE <br />I <br />DIMENSIONS GREATER THAN 1/2" <br />HANGER WIRES AND BRACING WIRES - 3 TURNS <br />G TYPICAL SADDLE TIE <br />1/4" DIA. SCREW EYE WrTH 1 1/4" MIN. <br />PENETRATION <br />o HANGER WIRE <br />^� 1" MIN. <br />z <br />MICRO -LAM LOWER FLANGE NOTE: DO NOT INSERTSC RE <br />W EYES <br />U I"'I PARALLEL TO LAMINATIONS (SEE DETAIL F) <br />E (DETAIL MAY ALSO BE USED AT TOP CHORD) <br />1 5) SUSPENDED CEILING NOTES (1 2) WIRE CONNECTIONS TO WOOD CONSTRUCTION <br />SCALE: V= 1'-0" SCALE: 11/2"= 1'-0" <br />3 <br />O <br />zZ <br />6 <br />NOTES: <br />1. ALL WIRE TO BE SADDLE TIED <br />2. INSTALLATION TO COMPLY WITH <br />2016 CBC SECTION 808, ASCE 7-10, <br />ASTM C 635 & C 636 <br />A.C. LAY -IN PANEL <br />7) SUSPENDED CEILING DETAIL AT WALL <br />SCALE: NTS <br />0 <br />TYPICAL CEILING DETAILS <br />SCALE: 1/8" = V-0' <br />PERIMETER STARTER <br />WALLS <br />4 EACH, 12 GA. SPLAY <br />WIRES 0 12'-0" O.C. <br />MAX & 6'-0' MAX <br />FROM WALLS - SEE <br />DETAILS 7/AD8 <br />COMPRESSION STRUT <br />AT 12'-0" O.C. MAX <br />(6'-0" MAX FROM END <br />OF RUNNER) - SEE <br />DETAIL 10/AD8 <br />'ti" STRUT AS REQUIRED <br />2XBLOCKAT24" O.C. KVVr IKU� <br />WITH A35 EACH END <br />TO TRUSS <br />ESUSPENDED CEILING <br />(3) #12D VT/ <br />ADIABRA <br />\.. <br />— — — _ — — <br />A35 EACH <br />2X4 STUDS AT 24" <br />O.C. WITH (4) SDS <br />TO 2X BLOCK <br />2X4 � 24" O.C. WITH <br />(3) # 10 SDS EACH <br />STUD <br />16 GA. CORNER <br />ANGLE <br />5/8" GYPSUM BOARD - <br />CONTINUE TO WALL AT I LINE OF WALK-IN <br />AREA BETWEEN COOOLER I COOLER AS OCCURS <br />1 <br />1) <br />CEILING FRAMING <br />9) C6 <br />HANGER WIRES 0 ALTERNATE <br />CORNERS TO THE STRUCTURE ABOVE <br />FIXTURE BRACING DETAIL <br />SCALE: 1 /2" = V-0' <br />O <br />O <br />9 <br />z <br />6 <br />K� <br />LATERAL FORCE BRACING <br />4 EACH #12 GAUGE WIRE <br />SEC U RED TO MAIN <br />RUNNER WITHIN 7' OF <br />CROSS TEE INTERSECTION <br />AND SPLAYED 900 FROM <br />BOTH DIRECTIONS WITH <br />FIRST POINT WITHIN 6' <br />FROM STARTING CORNER <br />COMPRESSION POST — <br />ATTACHED TO THE <br />STRUCTURE W/ (2) #12 <br />SCREWS TO ROOF DECK <br />1 /4" MACHINE - <br />BOLT <br />HEAVY DUTY — <br />CROSSRUNNER <br />HEAVY DUTY — <br />MAIN RUNNER <br />SPLAY BRACING NOTE: <br />CROSS -FURRING SHALL BE SECURELY ATTACHED TO THE MAIN <br />RUNNER BY SADDLE TYING WITH NOT LESS THAN ONE STRAND <br />OF NO. 16 OR TWO STRANDS OF NO. 18 US. GAUGE TIE WIRE <br />OR APPROVED EQUIVALENT ATTACHMENTS. <br />RUNNERS AND FURRING: THE MAIN RUNNER AND <br />CROSS -FURRING SHALL BE NOT LESS THAN THE SIZES SET FORTH <br />IN TABLE NO. 47-A, EXCEPT THAT OTHER SECTIONS OF <br />EQUIVALENT STRENGTH MAY BE SUBSTITUTED FOR THOSE SET <br />FORTH IN THIS TABLE. <br />#12 GAUGE <br />\ T WIRTICALHANGER <br />'O.C. <br />WIRE @ 4'-0" O.C. <br />TYPICAL CEILING DETAILS <br />SCALE: NTS <br />44W.?. P PRy PROP <br />W-tRGN.I OF 1Nl <br />X� QNG t#A M <br />3pl COPYRIGHT 2019 <br />REVISIONS <br />THIS DOCUMENT, AND THE IDEAS AND DESIGNS <br />INCORPORATED HEREIN, AS AN INSTRUMENT OF <br />PROFESSIONAL SERVICE, IS THE PROPERTY OF <br />"api" AND IS NOT TO BE USED, IN WHOLE OR IN <br />PART, FOR ANY OTHER PROJECT WITHOUT <br />WRITTEN AUTHORIZATION. <br />PLANNING ■ ■ ■ <br />ARCHITECTURE <br />ARCHITECTURE PLUS INC. <br />4335-B NORTH STAR WAY <br />MODESTO, CA 95356 <br />ph. 209.577.4661 <br />fx. 209.577.0213 <br />www.apiarc.com <br />FRANK C. BOOTS <br />JOSEPH L. SMITH <br />RODNEY C. ALONZO <br />ARCHITECTS <br />W Z a <br />W owe <br />DC�z <br />a W O <br />99 <br />�0m <br />S <br />H <br />Q d O <br />Nc�z <br />•d <br />�Q Z a <br />ii Q OOC <br />OC <br />Lu <br />UJ W <br />Q <br />ru <br />in <br />DATE: JULY 2619 <br />JOB NO.: 18-114 <br />DRAWN: A. ZAPIEN <br />CHECKED: J. SMITH <br />SHEET: <br />AD3 <br />U <br />z <br />0 <br />OC <br />7/8" WALL ANGLE <br />NOTE: <br />8" MAX. <br />• COMPRESSION STRUTS: STEEL SECTION WITH L/R RATIO OF <br />#12 GAUGE VERTICAL HANGER <br />200 MAX, SECURE TO MAIN RUNNERS WITH 1 /4" MB AND TO <br />WIRE @ 4'-0' O.C. <br />STRUCTURE WITH 3/16" 0 POWER DRIVEN CLIPS <br />`a <br />• COMPRESSION STRUT SHALL NOT REPLACE HANGER WIRE <br />HEAVY DUTY MAIN RUNNER <br />ATTACHED <br />I °, <br />VERIFY LAYOUT WITH REFLECTED <br />WALL W/POP RIVET <br />COMPRESSION STRUT- <br />12 GA. VERT. HANGER <br />CEILING PLAN <br />°Qp <br />SEE DETAIL 10/ADS <br />WIRE @ 4'-0"O.C. W/MIN <br />(3) TIGHT TURNS IN 1 1/7' <br />NOTES: <br />12 GA. SPLAYED WIRE <br />• HANGER WIRES TO BE 12 GAGE FOR 48" SPACING <br />7/8" WALL ANGLE <br />BRACE WITH MIN {4) <br />TIGHT TURNS IN 1 1 /2" <br />• SUSPENSION SYSTEM ARMSTRONG "PRELUDE XL" OR APPROVED STRUCTURAL EQUAL <br />BERC2 <br />8" MA) <br />#12 GAUGE VERTICAL HANGER <br />•ENDS OF MAIN RUNNERS AND CROSS MEMBERS TO BE TIED TOGETHER WITH 16 GA. WIRE 70 PREVENT <br />WIRE 0 4'-0' O.C. <br />SPREAD <br />• WIRES GREATER THAN I IN 6 OUT OF VERTICAL TO HAVE COUNTER WIRING <br />HEAVY DUTY MAIN RUNNER <br />• CEILING MAY BE ATTACHED AT 2 WALLS MAX - PROVIDE 3/4" MIN CLEAR AT FREE ENDS <br />d <br />450 <br />ATTACHED <br />°' `a <br />• 4 DIAGONAL BRACING WIRES / 144 S.F. (MIN 7T DISTANCE FROM WALLS) <br />WALL W/BERC2 CLIP <br />tl, <br />6 <br />• HANGER WIRES, 5 TIGHT TURNS - 12 GAUGE BRACE WIRES, 4 TIGHT TURNS <br />• ALL CEILING WIRES AND UNBRACED DUCTS, PIPES, ETC. TO HAVE MIN 6' SEPARATION <br />450 <br />SCO <br />7 <br />• ALL LIGHT FIXTURES AND DUCT TERMINALS ATTACHED TO CEILING GRID TO RESIST HORIZONTAL FORCES <br />MAX <br />MAX <br />EQUAL TO WEIGHT <br />7/8" WALL ANGLE <br />• RECESSED FIXTURES AND DUCT TERMINALS LESS THAN 56 LBS, SHALL BE SUPPORTED BY SAFETY WIRES <br />BERC2 <br />8" MA <br />{SLACK) TO OVERHEAD STRUCTURE <br />#12 GAUGE VERTICAL HANGER <br />WIRE 0 4'4'0.C. <br />• SURFACE MOUNTED FIXTURES AND DUCT TERMINALS TO BE SUPPORTED WITH MINIMUM OF 2 - 14 GAGE <br />CLAMPS WHICH SURROUND RUNNER SUPPORT BY 12 GAGE WIRE TO OVERHEAD STRUCTURE (NO <br />0 <br />' ". <br />(7 <br />ROTATIONAL SPRING CUPS) <br />3: <br />*' F <br />30 <br />2" MAX FROM <br />O <br />, <br />' <br />/g <br />`c <br />HEAVY DUTY MAIN RUNNER <br />BRACE WIRES TO <br />\ MAIN RUNNER <br />3 <br />• PENDANT FIXTURES TO BE SUPPORTED TO OVERHEAD STRUCTURE WITH DEVICE CAPABLE OF CARRYING 4 <br />R <br />UNATTACHED <br />WALL W/BERC2 CLIP <br />CROSS RUNNERS <br />R <br />XTHE FIXTURE'S WEIGHT <br />Z <br />tl`a <br />"ARMSTRONG - SEISMIC Rx" <br />z <br />CROSS RUNNER <br />• FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS <br />w <br />U <br />SUSPENSION SYSTEM <br />U <br />ICC - ESR -1308 <br />Q <br />u <br />• FIXTURES AT 1 HOUR CONSTRUCTION TO BE WRAPPED TO MAINTAIN CONTINUITY OF FIRE ASSEMBLY <br />Q <br />• PROVIDE RIGID STEEL TUBING STRUTS AS REQUIRED BY ASTM C635 AND CBC SECTION 2506.2.1 <br />r8) <br />SUSPENDED <br />CEILING <br />GRID ATTACHMENT <br />r5) <br />TYPITCAL CEILING DETAIL <br />r2) <br />SUSPENDED CEILING <br />9) C6 <br />HANGER WIRES 0 ALTERNATE <br />CORNERS TO THE STRUCTURE ABOVE <br />FIXTURE BRACING DETAIL <br />SCALE: 1 /2" = V-0' <br />O <br />O <br />9 <br />z <br />6 <br />K� <br />LATERAL FORCE BRACING <br />4 EACH #12 GAUGE WIRE <br />SEC U RED TO MAIN <br />RUNNER WITHIN 7' OF <br />CROSS TEE INTERSECTION <br />AND SPLAYED 900 FROM <br />BOTH DIRECTIONS WITH <br />FIRST POINT WITHIN 6' <br />FROM STARTING CORNER <br />COMPRESSION POST — <br />ATTACHED TO THE <br />STRUCTURE W/ (2) #12 <br />SCREWS TO ROOF DECK <br />1 /4" MACHINE - <br />BOLT <br />HEAVY DUTY — <br />CROSSRUNNER <br />HEAVY DUTY — <br />MAIN RUNNER <br />SPLAY BRACING NOTE: <br />CROSS -FURRING SHALL BE SECURELY ATTACHED TO THE MAIN <br />RUNNER BY SADDLE TYING WITH NOT LESS THAN ONE STRAND <br />OF NO. 16 OR TWO STRANDS OF NO. 18 US. GAUGE TIE WIRE <br />OR APPROVED EQUIVALENT ATTACHMENTS. <br />RUNNERS AND FURRING: THE MAIN RUNNER AND <br />CROSS -FURRING SHALL BE NOT LESS THAN THE SIZES SET FORTH <br />IN TABLE NO. 47-A, EXCEPT THAT OTHER SECTIONS OF <br />EQUIVALENT STRENGTH MAY BE SUBSTITUTED FOR THOSE SET <br />FORTH IN THIS TABLE. <br />#12 GAUGE <br />\ T WIRTICALHANGER <br />'O.C. <br />WIRE @ 4'-0" O.C. <br />TYPICAL CEILING DETAILS <br />SCALE: NTS <br />44W.?. P PRy PROP <br />W-tRGN.I OF 1Nl <br />X� QNG t#A M <br />3pl COPYRIGHT 2019 <br />REVISIONS <br />THIS DOCUMENT, AND THE IDEAS AND DESIGNS <br />INCORPORATED HEREIN, AS AN INSTRUMENT OF <br />PROFESSIONAL SERVICE, IS THE PROPERTY OF <br />"api" AND IS NOT TO BE USED, IN WHOLE OR IN <br />PART, FOR ANY OTHER PROJECT WITHOUT <br />WRITTEN AUTHORIZATION. <br />PLANNING ■ ■ ■ <br />ARCHITECTURE <br />ARCHITECTURE PLUS INC. <br />4335-B NORTH STAR WAY <br />MODESTO, CA 95356 <br />ph. 209.577.4661 <br />fx. 209.577.0213 <br />www.apiarc.com <br />FRANK C. BOOTS <br />JOSEPH L. SMITH <br />RODNEY C. ALONZO <br />ARCHITECTS <br />W Z a <br />W owe <br />DC�z <br />a W O <br />99 <br />�0m <br />S <br />H <br />Q d O <br />Nc�z <br />•d <br />�Q Z a <br />ii Q OOC <br />OC <br />Lu <br />UJ W <br />Q <br />ru <br />in <br />DATE: JULY 2619 <br />JOB NO.: 18-114 <br />DRAWN: A. ZAPIEN <br />CHECKED: J. SMITH <br />SHEET: <br />AD3 <br />U <br />z <br />0 <br />OC <br />