Laserfiche WebLink
SAN JOAQUIN <br />CCUNT <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />Harney Lane 76 <br />141 E HARNEY LN, LODI <br />August 18, 2021 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />305 <br />HSC 25290.1, 25290.2, 25291 Failed to maintain secondary containment (e.g. failure of secondary containment <br />testing). <br />OBSERVATION: Blue-green brine was found in the 87 and diesel turbine pump sump and 87, 91, and D fill sumps. <br />REGULATION GUIDANCE: Secondary containment shall be impervious to the liquid and vapor of the substance <br />contained and constructed to prevent structural weakening as a result of contact with any hazardous substances <br />released from the primary containment. <br />CORRECTIVE ACTION: Per technician, Rhome Desbiens, approximately a total of 1.5 gallons of brine was pumped <br />out of the sumps. Brine was still observed in the 87 and 91 fill sumps after the technician stated he had removed the <br />brine. Immediately contact a properly licensed, trained, and certified contractor to make repairs to the UST system <br />under permit and inspection of the EHD. <br />This is a Class II violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 9/17/2021. <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br />of having them sign. Starting September 1, 2018, all in -office CERS help will be provided at EHD hourly rate <br />($152). To schedule an appointment, please call (209) 468-3420. <br />Documents provided during inspection: Inspection Report, List of Free CUPA Classes, Return to Compliance <br />Certification and Corrective Actions Statement. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received by: Date: August 18, 2021 <br />Inspector: <br />Inspector Phone: <br />Printed Name and Title: <br />VICKY VANG-LEE, EH Specialist <br />(209) 616-3028 <br />Email to Sandeep Dhanda, Environmental Contact <br />FA0024750 PR0543574 SCO01 08/18/2021 <br />EHD 23-01 Rev. 9/16/2020 Page 9 of 9 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />