Laserfiche WebLink
i <br /> Installation Gu ae: AdvanTexTM-AX Treat ment SystemLA <br /> System Start-Up <br /> Step 13A:Verify Pump Operation <br /> Verify both manual and automatic operation of the recircu- <br /> lation pump. Before running the pump, ensure that the <br /> tank's water level is at least 4" above the bottom float, but <br /> below the top float. Flip the MOA toggle switch in the con- <br /> trol panel to "Manual" to test manual operation of the <br /> pump. Return the MOA switch to "Automatic."To facili- <br /> tate quick testing of the automatic operation, temporarily <br /> set the programmable timer to short intervals, but no short- <br /> er than 15 seconds on, 15 seconds off. NOTE: Refer to the <br /> control panel instructions for more detailed operational <br /> features of the control panel itself. <br /> Step 1313:Verify Float/Alarm Operation <br /> Whenever an alarm condition occurs, the red light on the <br /> t1s" closed front of theanel will come on along with the audible <br /> p g <br /> Model _ -- Position hornThe audible portion of all alarms can be silenced by <br /> "A"Float F— <br /> Open pushing the illuminated light. The type of alarm condition <br /> Position can be detected by the type of alarm light as listed below. <br /> The positions of the floats and the alarm conditions can <br /> also be determined by viewing the LCD screen inside the <br /> Float differential diagram control panel. <br /> ALARM LIGHT INTERPRETATION <br /> High Water Alarm Steady light: high water alarm <br /> Tap Override Timer Blinkinglight: low water alarm <br /> Float (alarm signaled when the g <br /> liquid level raises the float <br /> to its closed position) To test the operation of the floats, remove the float stem <br /> from the pump vault. Both floats go from their "open" to <br /> "closed" position when the liquid level is near the center of <br /> Surge <br /> Volume the float collar. The differential (drawdown) of the float is <br /> approximately 1/8". <br /> Low Water Alarm Drop the bottom float to its open position to verify opera- <br /> Bottorn Redundant Off tion of the low level alarm. The alarm horn should sound <br /> Float (alarm signaled when the and the red alarm light should begin blinking. When the <br /> liquid leve!drops the float g g g <br /> to its open position) low level alarm is activated, the pump should also be inop- <br /> Float positioning erable, Verify pump inactivation by flipping the MOA <br /> switch to manual. During normal system operation, the <br /> bottom float will be in its closed (up) position. <br /> © 2001 Orenco systems, Inc. EIM-ATX-AX-1 <br /> Information subject to change without notice Rev 1.48101 <br />