My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/8/2021 4:48:00 PM
Creation date
2/22/2021 2:00:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
763
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VR-201-Z/VR-202-Z -3- Exhibit 15 <br /> assay result, (3) the dates the assay was performed, and (4) the organization and specific <br /> personnel who performed the assay. <br /> 6. PRE-TEST REQUIREMENTS <br /> Install all required testing apparatus as illustrated in Figure 1. Connect the calibration test <br /> gas to the inlet of the HC sensor. Install the outlet tubing to the HC sensor outlet tee. This <br /> tubing is used to vent off calibration gases and processor exhaust to atmosphere away from <br /> testing personnel. <br /> 6.1 Pre-Test HC Analyzer Calibration: <br /> 6.1.1 Follow the HC Analyzer manufacturer procedures for instrument <br /> start-up and warm-up. <br /> 6.1.2 Check the zero reading of the HC analyzer using nitrogen following the <br /> manufacturer's procedure. If the result is ± .10%, re-zero the instrument per <br /> the manufacturer's recommended procedures. Record the zero gas <br /> calibration gas concentration (% propane) on Form 1. <br /> 6.1.3 Set the span on the instrument to the HC concentration of the High-Range <br /> calibration gas cylinder. <br /> 6.1.4 Check the calibration of the HC analyzer by running the calibration check <br /> gas following the manufacturer's procedure. Record the High-Range <br /> calibration gas concentration on Form 1. If the result is outside of the <br /> required range, then the analyzer shall be recalibrated per manufacturer <br /> specifications prior to conducting the test. <br /> 6.1.5 Check the Low-Range calibration of the analyzer by running the low-end <br /> calibration gas per the manufacturer's procedure. If the result is outside the <br /> minimum instrument accuracy as stated in section 4.7, then the analyzer <br /> shall be recalibrated per manufacturer specifications prior to conducting the <br /> test. Record the Low-Range range calibration gas concentration on Form 1. <br /> After a minimum of 10 minutes, record the reading on the instrument. <br /> 7. TEST PROCEDURE <br /> 7.1 Compliance Procedure: <br /> 7.1.1 Install a section of tubing from the Permeator Exhaust Test Port (See Figure <br /> 2) into the HC Analyzer and turn on the analyzer sample pump. Set the inlet <br /> test gas flow rate to 2 scfh. Adjust the flow rate as necessary during the test <br /> to maintain the correct flow rate. If the flow is lower than 2 scfh, verify that <br /> there are no kinks or obstructions in the tubing. If the flow is still lower than <br /> that, consult the manufacturer of the HC Analyzer for troubleshooting sample <br /> pump operation. <br /> 7.2.2 If the Permeator is running, begin a stopwatch and wait ten (10) minutes. <br /> If the Permeator is Off, wait until it starts and then begin a stopwatch and <br /> wait ten (10) minutes. After either of these 10 minute periods, record the HC <br /> Analyzer reading and the time on Form 1. <br />
The URL can be used to link to this page
Your browser does not support the video tag.