Laserfiche WebLink
DRW NO:9900-9973 <br /> FLOAT CHECK VALVE <br /> P/N 9466G <br /> OVERFILL PROTECTION <br /> (VERTICAL INSTALL ONLY) 1"VENT REFERANCE® AIR BREATHER ASM. NOTICE <br /> 100 FT.MAX. LENGTH WITH AIR(IN/OUT) DRAWINGS ARE TWO DIMENSIONAL <br /> 1/e"PER FOOT PITCH P/N 9948 REPRESENTATION OF TYPICAL CLEAN AIR <br /> TOWARD VENT SEPARATOR (CAS) INSTALLATION. ACTUAL CA <br /> INSTALLATIONS WILL VARY SLIGHTLY FROM TH <br /> ----- } REPRESENTATION SHOWN. <br /> 1• 12'MINIMUM <br /> INSTALLER SHALL NOT LOOSEN, ROTATE OR REM VE <br /> VENT VALVES ABOVE GRADE FACTORY INSTALLED FITTINGS OR FLANGE AS THIS <br /> (SUPPLIED BY INSTALLER) -- _ ___ _ MAY DAMAGE FACTORY SEALS AND VOID WARRA TY. <br /> SEE I 1"BLADDER VAPOR INLET ASSN. <br /> NOTE I SYPHON <br /> 4 1"TEE WITH PLUG <br /> F ON 6"NIPPLE <br /> A SYPHON TUBE ADAPTER <br /> I I I I <br /> BALL VALVE I i <br /> 2"VENT PIPES I P/N 996123 `�"\ <br /> i LOCK <br /> PIW 996124 I I + I <br /> USE KEY <br /> P/N 996125 i I t rl Ij <br /> OI VAPOR <br /> tt I 104" REF. <br /> AS REQUIRED <br /> ' SYPHON TUBE <br /> AIR <br /> 400 GALLON BLADDER, <br /> VERTICAL <br /> I CLEAN AIR SEPARATOR(VCAS) <br /> (36"O.D.X 93"LG.) <br /> BALL VALVE i t i P/N 9931 (REF) <br /> P/N 996123 I <br /> LOCK \ <br /> P/N 996124 f/ <br /> USE KEY I I j! <br /> P/N 996125 <br /> 1"CONDENSATE DRAIN. <br /> I I I PLUG I <br /> VCAS SLAB,SEE DWG. <br /> ---- 9900-9945 FOR DETAILS. <br /> NOTE: <br /> 1 — ALL BALL VALVES(B.V.)TO BE UL LISTED AND HAVE — <br /> PADLOCK FEATURE. <br /> 2— PASSIVE PRESSURE CONTROL—NO ELECTRICAL <br /> POWER REQUIRED. <br /> 3— AIR BREATHER MUST BE INSTALLED AT A MINIMUM <br /> HEIGHT OF 12' ABOVE GRADE. <br /> 4— VENT LINE TIE IN CAN BE INSTALLED ANYWHERE <br /> ALONG THE VENT STACK LINE PROVIDED THAT PIPE <br /> SLOPE IS MAINTAINED AND THE CHECK VALVE IS IN <br /> THE CORRECT VERTICAL INSTALLATION. <br /> 5— ONLY GALVANIZED PIPE IS TO BE USED FOR PIPING <br /> CONNECTION 8 JAM NOTE 6 4016683/20/08 <br /> ®- A FLEXIBLE CONNECTION BETWEEN THE CLEAN AIR REV DESCRIPTION ECN NO BY DATE <br /> SEPARATOR AND THE VENT LINE(S)IS ALLOWABLE MATERIAL <br /> IF REWIRED BY THE LOCAL AUTHORITY HAVING mawm ,xw,:,p e.e rrwm Franklin Fueling Systems <br /> JURISDICTION (AHJ) TO MEET SEISMIC REQUIREMENTS. rwH°s�.lma nG xama nx ns.� uiN <br /> trues n«a�bt«m°tbn tlbdosa DO NOT SCALE DRAWNG JOE ±.D2 TITLE <br /> SHOULD THE FLEX CONNECTION BE INSTALLED SUCH <br /> THAT ITIS NOT SUPPORTED, THE SLOPE OF THE FLEX STANDARD INCH TOLERANCES .>a« :.005 CLEAN AIR SEPARATOR VERTICAL INSTALLATION(3 VENT) <br /> CONNECTION SHALL BE GREATER THAN THE 1/8" PER wm°».ami°..p.anaay ' (UNLESS OTHERWSE SPECKED) MUM t 1 2' <br /> FOOT SLOPE REQUIRED FOR THE REST OF THE ONE u«we a.Hare ey rro"xm / DRAIN: DAIS DRW NO: FII%: <br /> INCH GALVANIZED PIPING. D'x,H,°°,,,,°ea R"'°""'"9°niue1 JWH O5 14 02 <br /> ,�,F"„” sPE1uDIsl: 9900-9973 <br /> s»Lan°wm nwan. APMFDMB DAIF <br /> DB O6 OS 07 ACRD HLY ISME N.T.S. ISIUT 1 OF 1 <br />