DRW NO:9900-9972H <br /> NOTICE <br /> VENT VALVESDRAWINGS ARE TWO DIMENSIONAL <br /> (SUPPLIED BY INSTALLER) AIR BREATHER ASM. REPRESENTATION OF TYPICAL CLEAN AIR <br /> ---1 I AIR(IN/OUT) SEPARATOR (CAS) INSTALLATION. ACTUAL CAS <br /> I P/N 9948 INSTALLATIONS WILL VARY SLIGHTLY FROM THE <br /> I I I REPRESENTATION SHOWN. <br /> 12' MINIMUM INSTALLER SHALL NOT LOOSEN, ROTATE OR REMOtE <br /> I SUPPORT AIR BREATHER PIPE ABOVE GRADE FACTORY INSTALLED FITTINGS OR FLANGE AS THIS <br /> I VERTICALLY NTH THE VENT LINE I MAY DAMAGE FACTORY SEALS AND VOID WARRAN rY. <br /> i SUPPORT SYSTEM OR ITS OWN <br /> SUPPORT SYSTEM (DETERMINED BY 1"PIPE <br /> I INSTALLER) TO MEET LOCAL CODES. <br /> Em <br /> 2"VENT PIPES I i I <br /> I � I <br /> I I <br /> � I � <br /> AS REQUIRED I i <br /> I I <br /> HORIZONTAL <br /> FLOAT CHECK VALVE I CLEAN AIR SEPARATOR(HCAS) <br /> P/N 9466G I (36"O.D.X 93"LG.) <br /> OVERFILL PROTECTION P/N 9931H(REF) LIFTING LUG <br /> I ! (VERTICAL INSTALL ONLY) ITEE W/PLUG (2—PLACES) <br /> 1" <br /> NIPPLE <br /> I I 1"VENT REF. I 0 <br /> I 100'MAX.LENGTH <br /> i W/1/8 INCH/FT. PITCH <br /> TOWARD VENT AIR <br /> iF M <br /> TUBE <br /> 42"RE <br /> i A VAPOR <br /> _ B I C 4'X 8'HCAS SLAB <br /> ---- SEE DWG. 9900-9945H <br /> j SEE PLUG p <br /> I I 4TE <br /> E <br /> I-I I I-111-111-I I I-I I I-111-111-111-111 III I I-I I I I.': :..:':: '. •' .' •.:'.. �',. ...: f.: .. `' " " I-III-III-III-III-III-1 <br /> -1 I I-1 - <br /> NOTE: BALL VALVE P/N 996123 1"CONDENSATE DRAIN <br /> 1 — ALL BALL VALVES(B.V.)TO BE UL LISTED AND HAVE LOCK P/N 996124 <br /> PADLOCK FEATURE. KEY P/N 996125 VAPOR INLET ASM. 400 GALLON BLADDER <br /> 2— PASSIVE PRESSURE CONTROL—NO ELECTRICAL <br /> POWER REQUIRED. <br /> 3— AIR BREATHER MUST BE INSTALLED AT A MINIMUM SYPHON TUBE ADAPTOR <br /> HEIGHT OF 12' ABOVE GRADE ON 1"PIPE. <br /> 4— VENT LINE TIE IN CAN BE INSTALLED ANYWHERE <br /> ALONG THE VENT STACK LINE PROVIDED THAT PIPE <br /> SLOPE IS MAINTAINED AND THE CHECK VALVE IS IN <br /> THE CORRECT VERTICAL INSTALLATION. <br /> 5— ONLY GALVANIZED PIPE IS TO BE USED FOR PIPING <br /> CONNECTIONS. <br /> 6— HCAS TO SLOPE SLIGHTLY TOWARD CONDENSATE <br /> DRAIN. PITCH SLAB WITHIN 1/8 INCH/FOOT TOWARD <br /> CONDENSATE DRAIN END OR SHIM HCAS FOR PROPER 7 IAMNDTE7 4016663/20/08 <br /> VESSEL DRAINAGE. <br /> ®— A FLEXIBLE CONNECTION BETWEEN THE CLEAN AIR REV DESCRIPTION ECN NO BY DATE <br /> SEPARATOR AND THE VENT UNE(S)IS ALLOWABLE m.immnn•Lwx a.n•.°a n...•° MASA' <br /> IF REQUIRED BY THE LOCAL AUTHORITY HAVING e.•a�.vx.�r ny„•m,,,,x,x Franklin Fueling Systems <br /> JURISDICTION (AHJ) TO MEET SEISMIC REQUIREMENTS. vwny sem.°G x.iu..ni. aan sne <br /> em.Fs"�u•mx•x°��x awe..e DO NOT SCALE DRAM—NG---f M 2.02 MILE <br /> SHOULD THE FLEX CONNECTION BE INSTALLED SUCH in.,.°"m•r e.:a:°a°.a°, <br /> THAT IT IS NOT SUPPORTED, THE SLOPE OF THE FLEX L°°"-^�mne•°� STANDARD INf}I TOLERANCES .XXX 2.005 CLEAN NR SEPARATOR HORIZONTAL INSTALLATION(2 VEN VALVE) <br /> CONNECTION SHALL BE GREATER THAN THE 1/8"PER P., ..w ee°KK.y°u•m..uy°f mr (UNLESS OTHERa1SE SPECIFIED) ANGULAR 21 2' <br /> FOOT SLOPE REQUIRED FOR THE REST OF THE ONE _mg s.•i•x�.T,w 4."by "' / 7 DATE' <br /> 22 07 qiW NO, FFlX <br /> INCH GALVANIZED PIPING. n.—�x.am_..v 4 SPECIAL DIST: / / 9900-9972 H <br /> swl�x•xvm r•R°M APPRN.:0AIE <br /> MDB 06 05 07 SCALE: N.T.S. ISHEET 1 OF 1 <br />