Laserfiche WebLink
II. EASYGRIP BREAKAWAY RECONNECTION CLAMP <br /> TOOLS NEEDED: <br /> • EasyGrip Reconnection Clamp <br /> • 8 mm Hex Head Socket <br /> • Torque wrench <br /> • Safety Glasses <br /> RECONNECTION PROCEDURE <br /> NOTE: Additional information on the EasyGrip operation can be found by viewing a video clip on <br /> their website at http://www.simplegripl23.com/ <br /> 1. Inspect each half of the separated breakaway for obvious damage to the outer-shell, plastic <br /> inserts or o-rings; including cracks, chips or tears that may effect reconnecting the two halves. <br /> 2. Check the shear pin bushing hole, (See Figure 1) located in the top half of the breakaway for <br /> any part of the pin left behind at separation. A gentle tap on the opposite side of the breakaway <br /> should eject the pin. <br /> i <br /> Figure 1 <br /> 6-4 <br /> CARE Approved IOM 0-Healy Breakaway Model 8701VV-Executive Orders VR-201 and VR-202 <br />