Laserfiche WebLink
IL •- } t <br /> i <br /> I <br /> 1 k <br /> Photo S Photo T <br /> ❑ Leave the wires coming from the sealed nipple assembly at least six inches longer than <br /> necessary to reach the bottom of the compartment. Cut off excess and strip all wires 1/2". <br /> ❑ Connect the wires from the sealed nipple to the interface module as follows: <br /> ■ Black wire to `motor ` on module <br /> ■ White wire to `neutral' on module <br /> ■ Red wire (either) to `output Von module <br /> ■ Red wire (other) to `output 2' on module <br /> ■ Orange wire to `fault common' on module <br /> ■ Purple wire to `fault input' on module <br /> ■ Green wire needs a #8 ring tong lug installed and connected to any chassis ground <br /> (frame) <br /> ■ Some sealed nipples may have some extra wires, cap these and bundle them neatly <br /> out of the way. <br /> ❑ The black and white twisted pair of wires with a connector should be connected to <br /> an available AC outlet on the dispenser Relay Board #887225. <br /> ❑ The male/female multiconductor cable that is wired to the interface module is routed up to <br /> the computer board # 173976, see photo T. Disconnect the valves cable that's in the J3 <br /> connector and install in the female side of the double connector on the harness. The entire <br /> assembly is then installed back into J3 on the Computer board. WIRING IS COMPLETE. <br /> ❑ Mount the interface module as shown in Photo S using the 8-32 x 5/8" screw, washer and <br /> nut supplied in the electrical kit. <br /> 8-13 <br /> CARE Approved IBM 8-Wayne Harmony Series(Assist)-Executive Orders VR-281 and VR-282 <br />