Laserfiche WebLink
10. INSTALLING THE VP1000 SYSTEM: <br /> NOTE: The mounting bracket on the VP1000 must be rotated 900 to secure the pump on <br /> this shelf. When installed in the dispenser, the vacuum pump INLET must be on top and the <br /> OUTLET on the bottom <br /> i <br /> PHOTO M <br /> ❑ Place the VP1000 vapor pump on the sheet metal bracket with the pump end towards the <br /> left, upturned flange, see photo M. Secure with one 1/4-20 x 5/8" flat head cap screw, <br /> washer and nut in each of the motor mounting holes closest to the electrical end. <br /> NOTE: DO NOT USE PIPE SEALING COMPOUND ON ANY ELECTRICAL CONDUIT <br /> FITTINGS. <br /> Mount the electrical conduit on the VP 1000: (See Photo N Below) <br /> ❑ Get the 1/2" x 3" conduit nipple and thread through the motor wires to secure the nipple into <br /> the motor. <br /> ❑ Install the 1/2" electrical elbow to the nipple from above — use care not to twist the wires <br /> during the installation. Completely tighten the elbow to face toward the rear of the VP1000, <br /> see photo N. <br /> ❑ Next, install, in the elbow, the 1/2" close nipple, followed by the female half of the electrical <br /> union. <br /> 8-D <br /> CARE Approved IOM 8-Wayne Ovation Series-Executive Orders VR-PDI and VR-202 <br />