COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1403
>
2300 - Underground Storage Tank Program
>
PR0231995
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 3:31:12 PM
Creation date
3/26/2021 3:44:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231995
PE
2361
FACILITY_ID
FA0006438
FACILITY_NAME
United # 5446
STREET_NUMBER
1403
Direction
W
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12323246
CURRENT_STATUS
01
SITE_LOCATION
1403 W COUNTRY CLUB BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Certificate Number:02-019A24 <br /> Page 14 of 19 <br /> Gilbarco,Inc. <br /> Retail Motor Fuel Dispenser(RMFD)/Nxx Series <br /> NCWM Publication 14. The manufacturer requested additional testing with up to E25 to align with UL87A 5t' edition and in <br /> anticipation of EPA changing the ethanol content for "standard" gasoline. Each meter was evaluated with gasoline containing 25% <br /> ethanol (E25) as the test fluid. Accuracy testing was done at 3 flow rates for both the initial and subsequent test. The T19976-G3 <br /> meter was evaluated after having dispensed gallons 43,663 gallons of E25,followed by 46,592 gallons of gasoline followed by 17,687 <br /> gallons of E25 with a total throughput of 107,942 gallons. The T19976-V3 meter was evaluated after having dispensed gallons 44,004 <br /> gallons of E25, followed by 46,598 gallons of gasoline followed by 17,677 gallons of E25 with a total throughput 108,279 gallons. <br /> The manufacturer stated that switching from E25 then to gasoline and then back to E25 represented the worst case testing for the <br /> meters. No changes were made to the standard T19976-G3 and T19976-V3 meters. Because these are the same models as previously <br /> evaluated with no internal or external differences,photos of the meter in the manufacturer's equipment was not provided. The device <br /> evaluation was based on the 2010 edition of NIST Handbook 44 and NCWM Publication 14. The device complies with applicable <br /> requirements. <br /> Model NBO and references to the use of the Murray model 989 meters is being removed from the certificate at the manufacturer's <br /> request. This model and meter were never placed into production and will not be used. <br /> Certificate of Conformance Number 02-019A15: This certificate supersedes Certificate of Conformance number 02-019A14 and is <br /> issued noting the addition of a new Gilbarco meter model T19976-V3.This meter is the same as the manufacturers T19976 G1 and G2 <br /> with a new piston and meter end cap as CC No. 02-038A4. Testing was conducted at the manufactures test facility using a Gilbarco <br /> Encore series dispenser with the T19976-V3 meters installed. The 2009 edition of NCWM Publication 14 was the basis for the <br /> evaluation. The meter was evaluated with gasoline and diesel as the test fluids.Accuracy testing was done at 3 flow rates for both the <br /> initial and subsequent test. Each meter was retested after having dispensed 22290 gallons of gasoline and 20465 gallons of diesel. <br /> Other than the model number on the meter,no external differences are notable and photo of the meter in the manufacturer's equipment <br /> was not provided. <br /> Certificate of Conformance Number 02-019A14: This certificate supersedes Certificate of Conformance number 02-019A13 and is <br /> issued noting a new Gilbarco pulser, Model: M09040xxxx for Encore 500 and Model: M09261xxxx for Encore 300. The dispenser <br /> with the new pulser was evaluated and tested at the manufacturer's facility using the 2008 edition of NCWM Publication 14 as the <br /> basis for the evaluation.Accuracy testing was done at 3 flow rates.Subsequent testing was not deemed necessary. <br /> Certificate of Conformance Number 02-019A13: This certificate supersedes Certificate of Conformance number 02-019Al2 and is <br /> issued noting a change in the minimal flow rate of the Gilbarco Model T19976 Gx meter series.No changes were made to the T19796 <br /> Gx series meters.A change in the meter minimum flow rate is needed to meet new customer demands. The meter was placed into the <br /> manufacturer's Encore series dispenser for testing. The dispenser with the T19976 Gx meters was evaluated and tested at the <br /> manufacturer's facility using the 2008 edition of NCWM Publication 14 as the basis for the evaluation. E100 (100% ethanol) and <br /> "Worthpar7"as a 100%biodiesel equivalent(10 centipoises)were used as the test fluids.Accuracy testing was done at 3 flow rates for <br /> both the initial and subsequent test. Each meter (2 meters tested) was retested after having dispensed 20,002 gallons of E100 and <br /> 20,108 gallons of Worthpar7(B 100). <br /> Additionally, meters models M02950, T20453-GX and the Murray 989 meters were removed from the list of options. The <br /> manufacturer no longer offers these models. Models numbers:NB 1,NB2,NB3,NB4,NFO,NF1,NF2,NMO,NMI,NM2, and NM3 <br /> were removed from the model code list(page3)and were never offered by the manufacturer. The name of the M07300 series meters <br /> changed from E-meter to Ecometer. <br /> Certificate of Conformance Number 02-019Al2: This certificate supersedes Certificate of Conformance number 02-019A1 I and is <br /> issued to add:FlintLoc Security System,Encrypted Card reader,Encrypted PIN pad and to document changes to the Audit trail. <br /> Flintloc device is not manufactured by Gilbarco.The FlintLoc System may be added to existing units or may be provide on the unit by <br /> Gilbarco. The system will require the use of a special remote "key"to deactivate the system. Opening the electronics cabinet without <br /> first deactivating the security device will trigger an audible alarm and flashing light. The device does not have any metrological <br /> features. <br /> Encrypted PIN pad and Encrypted Card Reader-The credit card industry is mandating that information from a credit/debit card and <br /> from the PIN pad be encrypted to reduce fraud. The encrypted data is then sent to the card company and the transaction proceeds as a <br /> Normal credit/debit card.The use of the encrypted data does not affect the metrological function of the dispenser.The Encrypted PIN <br />
The URL can be used to link to this page
Your browser does not support the video tag.