Laserfiche WebLink
UNDERGROUND UTILITIES ❑Confirm appropriate underground utility clearance procedures have been completed prior to ground <br /> penetrations,and employ other utility clearance/locator practices,as appropriate for conditions. <br /> ❑Hand digging or vacuum post-holing within 3'of utility locations or other high risk condition. <br /> B.10.CONFINED SPACE ENTRY,HAZARDOUS ENCLOSED SPACES ❑ Applicable ® Not Applicable,Not Anticipated <br /> EXPLANATORY NOTES,CLARIFICATIONS: <br /> CONFINED SPACE(S) ❑Develop effective site-specific entry procedure per applicable regulatory requirements: <br /> Potential/actual hazards: . Personnel to be trained/qualified. <br /> ❑Atmospheric hazards: • Hazards properly characterized <br /> ❑Flammable/explosive • Use equipment necessary for safe entry(for access,retrieval,PPE,air monitoring,ventilation) <br /> ❑Oxygen deficiency Develop measures for emergency rescue,as applicable. <br /> ❑Hydrogen sulfide • IMPORTANT: <br /> ❑Other toxic - Describe site-specific safety measures above in Explanatory Notes,Clarifications <br /> ❑Combustible dust - Modify this THA or attach separate confined space safety plan/permit,as appropriate <br /> ❑Electrical <br /> ❑Mechanical,engulfment, ❑Protect non-entry personnel working near confined spaces through control measures to prevent unauthorized <br /> entrapment,stored energy entry(such as safety orientation,labeling,delineation,barriers) <br /> Geosyntec Procedure(s):HS-111-Air Monitoring,HS-112-Respiratory Protection, <br /> HS-113-Personal Protective Equipment,HS-118-Confined Space Entry,Others as applicable <br /> HAZARDOUS ENCLOSED OR ❑Use personal protective clothing to protect from chemical,physical,biological hazards. <br /> INDOOR SPACE(S) ❑Use respiratory protection,if necessary/appropriate. <br /> ❑Indoors(occupied or vacant) ❑Duct equipment exhaust to outdoors using passive duct or active exhaust ventilation. <br /> ❑Machine/equipment pit/vault ❑Use fans,blowers or other effective means of ventilation to introduce fresh air/dissipate atmospheric hazards. <br /> ❑Basement/crawl space ❑Conduct air monitoring,as appropriate for conditions and hazards(see Part C,"Air Monitoring"). <br /> ❑Tunnel,shaft,gallery ❑For a trench/excavation,also see subsection entitled"Trenching/Excavation"in Section B.7."Construction, <br /> ❑Trench,excavation Heavy Equipment,Lift Equipment." <br /> ❑Hazardous exhaust or emissions ❑If space classified/regulated as a"confined space,"follow confined space entry requirements(above). <br /> ❑Building-related hazards <br /> Geosyntec Procedures:HS-111-Air Monitoring, <br /> HS-112-Respiratory Protection,HS-113-Personal Protective Equipment, Others as applicable <br /> B.11. STORAGE OF BULK MATERIALS ❑Applicable ® Not Applicable,Not Anticipated <br /> EXPLANATORY NOTES,CLARIFICATIONS: <br /> STORAGE OF BULK MATERIALS ❑Store materials in stable manner(stacked,racked,blocked,interlocked,tied,wrapped,or otherwise secured) <br /> to prevent tipping,sliding,rolling,falling or collapse. <br /> (for Storage of Hazardous Materials, ❑Do not exceed load limits of racks,platform,scaffold;ensure racks are stable,robust,secure. <br /> See Section B.13.) ❑Ensure stored materials do not block aisles,passageways. <br /> B.12. INFECTIOUS 1 ALLERGENIC BIOHAZARDS ❑Applicable ® Not Applicable,Not Anticipated <br /> EXPLANATORY NOTES,CLARIFICATIONS: <br /> F1 ❑Wastewater,sewer ❑Low hazard-use basic hygiene practices,protective gloves,provide for hand washing. <br /> ❑Bird Guano ❑More severe hazard-add protective clothing,respirator/dust mask,decon,as appropriate. <br /> ❑Mold,fungi,Valley Fever ❑For human pathogens use"Universal Precautions'per Bloodborne Pathogen Program. <br /> ❑Bloodborne pathogens <br /> ❑Other(describe above) Geosyntec Procedure(s):HS-133-Bloodborne Pathogens <br /> 6.13.COMMERCIAL CHEMICAL PRODUCTS ® Applicable ❑ Not Applicable,Not Anticipated <br /> EXPLANATORY NOTES,CLARIFICATIONS: <br /> PRODUCTS REGULATED BY HAZARD ❑Safety Data Sheets available,either on site or readily available within same work shift,containers labelled <br /> COMMUNICATION STANDARD properly,workers trained/oriented on hazards <br /> ❑For subcontractor use of chemical products,coordinate/discuss during safety meetings. <br /> ❑Conduct air monitoring,as appropriate(see Part C,"Air Monitoring,Worker Exposure Monitoring"). <br /> ® COMPRESSED GAS(flammable or ®Secure cylinders upright,caps on when not in use,handle with care,prevent damage. <br /> nonflammable) ❑Propane cylinders not in use must be stored outdoors in cage or similar secure enclosure. <br /> ❑Ensure acetylene cylinders NOT secured to steel arc welding bench. <br /> ❑Store/use in a manner to prevent asphyxiation hazard. <br /> ❑Segregate oxygen and fuel gases by distance(20')or barrier. <br /> ❑Control ignition sources. <br /> ❑"No smoking"signage at cylinder storage area for flammable gases. <br /> F EJUse/store in a manner to control inhalation exposure hazards,PPE,air monitoring. <br /> Geosyntec� THA(ver.2)—Task 1 -Driving October 22,2020 <br /> Lincoln Center-SAC1111 Page 8 <br /> consultants <br />