Laserfiche WebLink
Standard Features <br />0 <br />Orenco S -Series Simplex Control Panel (SIETMCT shown) <br />�, 3 Ijl jl <br />CZV�j <br />5 IIII <br />O� <br />Feature <br />Specifications* <br />1. Motor -start contactor <br />120 VAC: 17 FLA, 1 hp (0.75 kW), 2.5 million cycles at FLA <br />240 VAC: 17 FLA, 3 hp (2.24 kW), 2.5 million cycles at FLA <br />4. Auto/Off/Man toggle switch <br />Single -pole, double -throw HOA switch <br />2. Controls circuit breaker <br />10 A, OFF/ON switch, single pole, DIN rail mounting with thermal magnetic tripping characteristics <br />3. Pump circuit breaker <br />tripping characteristics <br />20 A, OFF/ON switch, single pole (120 VAC) or double pole (240 VAC), DIN rail mounting with thermal magnetic <br />5. Audible alarm <br />95 dB at 24 in. (610 mm), warble -tone sound; gasketed, UL Type 4X (IP66) <br />6. Audible alarm silence relay <br />Automatic reset, DIN rail mount <br />7. Visible alarm <br />7B -in. (22 -mm) diameter red lens, "Push -to -silence," UL Type 4X (IP66), 1 W LED light <br />8. Enclosure <br />UV -resistant fiberglass and stainless steel, UL Type 4X (IP66) <br />Optional Features <br />Feature <br />Specifications* Product code adder <br />Intrinsically safe <br />control relays <br />Listed per UL 698A, for Class 1 Div. 1, groups A, B, C, D hazardous locations <br />(Requires larger enclosure) <br />IR <br />Programmable timer <br />Repeat cycle from 0.05 seconds to 30 hours; separate variable controls for OFF & ON time periods <br />PT <br />Redundant off relay <br />DIN rail mount; provides a secondary off; sounds alarm upon low level condition <br />RO <br />Elapsed time meter <br />7 -digit, non-resettable; limit of 99,999 hours; accurate to 0.01 hours <br />ETM <br />Event counter <br />6 -digit, non-resettable <br />CT <br />Heater <br />anti -condensation heater; self-adjusting: radiates additional wattage as temperature drops <br />HT <br />Pump run light <br />7i8 -in. (22 -mm) diameter green lens; UL Type 4X (IP66), 1 W LED light <br />PRL <br />Power light <br />7B -in. (22 -mm) diameter green lens; UL Type 4X (I1366), 1 W LED light <br />PL <br />Surge arrestor <br />Status light on unit; protects incoming power supply from electrical surges <br />SA <br />Test Switch <br />Momentary switch for alarm testing <br />TS <br />' All voltages are 120 VAC unless otherwise noted <br />NTD -CP -S-1 Orenco Systems° Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com <br />Rev. 2.0, © 03/17 <br />Page 2 of 2 <br />