Laserfiche WebLink
A <br />V <br />Daily & Intermediate C��er <br />Comments �E,r ,���f ? � � � ` <br />- <br />r,�...'�,, .v ,_lr a. ,-.cv ,,,, _ -. ,<i ,.., z,iJx., --... <br />�� <br />_i nda4 S✓ -r-- _ .. ,tx. ... h n. ,,;r ,pier;.. .,..`� .vb'_.n <br />20670 - Availability Cover Material <br />20680 - Daily Cover <br />20690 - Alternative Daily Cover <br />20700 - Intermediate Cover <br />20695 - Performance Standards <br />20686 - Beneficial ReUse <br />A <br />... <br />Y <br />Handling J`quipmQnt & Ma>iketce <br />.. _ ,.,.,,_ <br />Comments F <br />20710 - Scavenging/Salvaging/Storage <br />20720 - Non -Salvageable Items <br />20730 - Volume Reduction/Energy Recovery <br />20740 - Equipment <br />20750 - Site Maintenance <br />A <br />-V <br />Controls, <br />20760 - Nuisance Control <br />20770 - Animal Feeding <br />20780 - Open Burning/Burning Wastes <br />20790 - Leachate Control <br />20800 - Dust Control <br />20810 - Vector and Bird Control <br />X <br />20820 - Drainage/Erosion Control <br />The facility has several areas where ponding is occuring. Pump or drain the larger areas <br />and when weather permits regrade to reduce ponding. <br />20830 - Litter Control <br />20840 - Noise Control <br />20860 - Traffic Control <br />20870 - Hazardous Wastes <br />20880 - Medical Wastes <br />20890 - Dead Animals <br />20900 - Air Criteria <br />�� <br />(toltime fl <br />A <br />Ga hMo�lton g & Co►itrol� ,v a <br />t§ < U <br />20919.5- Explosive Gas Control <br />20918 - Exemptions <br />20919 - Gas Control <br />X <br />20921 - Gas Monitoring and Control <br />T27CCR 20921 (a) (2) - Explosive Gas Control - The perimeter monitoring probes were <br />monitored during the routine inspection. The following was noted: GP 9 0% Methane (CH4) <br />for (S) (1) (D) probes; GP11 probes (S) 4.9% CH4 - (1) 4.0% CH4 - (D) 0% CH4; GP 12 <br />probes (S) 2.8% CH4 - (1) 3.1 % CH4 - (D) 0.5% CH4. <br />The facility operator needs to take the necessary steps to control the landfill gas at the <br />boundary. Any changes or modifications to the gas extraction system must have prior <br />approval from the SJVAPCD and the EHD. Review the gas system operations records to <br />determine if the gas levels are due to a line blockage or gas well field adjustment is <br />required. Review the Operations and Maintenance (O&M) manual to determine if all the <br />required maintenance was conducted. Evaluate the O&M manual to determine if <br />maintenance in adequate. <br />T27CCR 20921 (b) — Gas Monitoring and Control — The operator submitted a report titled <br />"Title 27 Compliance Review, Perimeter Probe Monitoring Network, Forward Landfill" on <br />September 16, 2008. The initial plan was reviewed by the EHD. The EHD requested more <br />information regarding surrounding land uses and structures located near the landfill. The <br />operator responded on December 12, 2008. The EHD reviewed the additional information <br />submitted and conducted a field investigation regarding the actual spacing of Gas probe <br />distances. The following was noted: <br />GP1 is 1 0010f from GP25 <br />GP24 is 1010ft from GP25 <br />GP16 is 1008ft from GP17 <br />GP3 is 998.5ft from GP4 <br />The plan is pending final review and comment from the EHD <br />20937 - Reporting Excessive Gas Con. <br />r � <br />'.. A <br />onpmn s. 'A <br />21780 - Submittal Closure Plans <br />