0 <br />21110 -Time Frame for Closure <br />I I PRC 44014(b) - Operator Complies with Terms & Conditions of ( I <br />l Permit <br />21640 - Review of Permits <br />21600 - Report of Disp Site Information <br />PRC 44004(a) - Significant Change <br />AC T27CCR 20939 (b) (1) — Sub -surface Landfill Gas Control Systems — The facility has experienced 5 subsurface landfill fires. Four of the fires occurred in this year. <br />The fires are all located along the toe of the slope. The latest fire occurred a long the western toe of the old Forward Inc portion of the landfill. The fire occurred along <br />the horizontal collector. The facility operator indicated that they would place soil over the area and monitor it. The operator provided a copy of the facility response plan <br />the pertained to sub -surface landfill fires. It is currently under review. It appears that the landfill gas system is over pulling and creating fires that erupt below the surface <br />of the landfill. Please see attacted letter dated 2/23/2009, from todd Thalhamer <br />Notes: <br />a. The green waste processing area has a lot of municple solid waste left in one load. The facility operator removed during inspection. <br />b. The following Violations or Areas of Concern listed on the previous inspection report have been corrected: <br />1. T27CCR 20870 - Hazardous Waste <br />2. T27CCR 20610 - Training <br />Signature> '` <br />