My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WALNUT GROVE
>
14001
>
2800 - Aboveground Petroleum Storage Program
>
PR0518071
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/18/2021 4:26:05 PM
Creation date
5/18/2021 4:19:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0518071
PE
2831
FACILITY_ID
FA0003163
FACILITY_NAME
WIMPYS MARINA CAFE
STREET_NUMBER
14001
Direction
W
STREET_NAME
WALNUT GROVE
STREET_TYPE
RD
City
WALNUT GROVE
Zip
95690
APN
00104002
CURRENT_STATUS
01
SITE_LOCATION
14001 W WALNUT GROVE RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLAN FIELD <br /> 112.7(g) Plan describes how to: ❑ Yes ❑No❑NA ❑ Yes ❑No❑NA <br /> • Secure and control access to the oil handling, processing and <br /> storage areas; For Oil Production Facilities: <br /> • Secure master flow and drain valves; Select NA <br /> • Prevent unauthorized access to starter controls on oil pumps; <br /> • Secure out-of-service and loading/unloading connections of <br /> oil pipelines; and <br /> • Address the appropriateness of security lighting to both <br /> prevent acts of vandalism and assist in the discovery of oil <br /> discharges <br /> 112.7(k) Qualified oil-filled operational equipment is present at the facility9 ❑ Yes❑No <br /> Oil-filled operational equipment means equipment that includes an oil storage container(or multiple containers)in which the oil is <br /> present solely to support the function of the apparatus or the device.Oil-filled operational equipment is not considered a bulk storage <br /> container,and does not include oil-filled manufacturing equipment(flow-through process). Examples of oil-filled operational <br /> equipment include, but are not limited to,hydraulic systems,lubricating systems(e.g. ,those for pumps,compressors and other <br /> rotating equipment,including pumpjack lubrication systems),gear boxes,machining coolant systems, heat transfer systems, <br /> transformers,circuit breakers,electrical switches,and other systems containing oil solely to enable the operation of the device. <br /> If YES Check which apply: <br /> Secondary Containment provided in accordance with 112.7(c) ❑ <br /> Alternative measure described below(confirm eligibility) ❑ <br /> 112.7(k) Qualified Oil-Filled Operational Equipment <br /> • Has a single reportable discharge as described in§112.1(b)from any oil-filled ❑ Yes❑No ❑NA <br /> operational equipment exceeding 1,000 U.S. gallons occurred within the three years <br /> prior to Plan certification date? <br /> • Have two reportable discharges as described in §112.1(b)from any oil-filled operational ❑ Yes ❑No ❑NA <br /> equipment each exceeding 42 U.S. gallons occurred within any 12-month period within <br /> the three years prior to Plan certification date?10 <br /> If YES for either, secondary containment in accordance with§1 12.7(c) is required <br /> • Facility procedure for inspections or monitoring program to ❑ Yes❑No❑ ❑ Yes ❑No❑NA <br /> detect equipment failure and/or a discharge is established and NA <br /> documented <br /> Does not apply if the facility has submitted a FRP under <br /> §112.20: <br /> • Contingency plan following 40 CFR part 109 (see Attachment ❑ Yes❑No❑ <br /> E of this checklist) is provided in Plan AND NA <br /> • Written commitment of manpower, equipment, and materials 11 Yes No bI <br /> required to expeditiously control and remove any quantity of NA <br /> oil discharged that may be harmful is provided in Plan <br /> Comments: <br /> Inspector Note- Complete, as applicable, either Attachment A or B which include additional <br /> requirements based on the type of facility. <br /> 9 This provision does not apply to oil-filled manufacturing equipment(flow-through process) <br /> 10 Oil discharges that result from natural disasters,acts of war,or terrorism are not included in this determination.The gallon amount(s)specified(either <br /> 1,000 or 42)refers to the amount of oil that actually reaches navigable waters or adjoining shorelines not the total amount of oil spilled.The entire <br /> volume of the discharge is oil for this determination. <br /> Tier I Qualified Facilities Page 8 of 8 June 2014 <br />