Table 7
<br /> Dual Phase Extraction System-Operating Data
<br /> Parcel 2A-L&M OU
<br /> 666 West Weber Avenue,Stockton,CA
<br /> Period Influent Effluent
<br /> Hourmeter Totalizer System Volume Average FI Well Field Operating System ■ Flow VOC VOC VOC1
<br /> Reading Reading Flow Discharged Flow Rate Rate Temperature Temperature Vacuum Rate [FID] [FID] Removed
<br /> Date hours (gal) al al (gal/day) (gpm) I (°F) (°F) (inHg) (scfm) (ppmv) (ppmv) (Ib/day) pH 12 Notes
<br /> 10/27/11 5,080.1 4,809,873 6,702,563 53,063 2,645 1.84 631 116.0 420.0 0.0 7.9 7.42 17
<br /> 11/15/11 5,081.7 4,813,770 6,706,460 3,897 205 0.14 -- -- -- -- -- 7.60
<br /> 12/15/11 5,081.7 4,815,174 6,707,864 1,404 47 0.03 7.80
<br /> 01/19/12 5,081.7 4,815,230 6,707,920 56 2 0.00 8.42
<br /> 02/28/12 5,081.7 4,817,956 6,710,646 2,726 68 0.05 7.13
<br /> 03/16/12 5,082.3 4,818,886 6,711,576 930 55 0.04 7.96
<br /> 03/29/12 5,082.3 4,821,747 6,714,437 2,861 220 0.15 --
<br /> 04/20/12 5,091.4 4,842,389 6,735,079 20,642 672 0.47 7.87
<br /> 05/08/12 5,098.1 4,846,480 6,739,170 4,091 227 0.16 90.0 13 96.8 900.0 0.0 7.99 18
<br /> 06/22/12 5,745.0 4,933,590 6,826,280 87,110 1,936 1.34 146.0 14 119.6 48.3 1.5 6.94
<br /> 07/12/12 5,747.6 4,935,171 6,827,861 1,581 79 0.05 -- -- -- -- -- 6.95 19
<br /> 08/15/12 5,748.3 4,938,873 6,831,563 3,702 109 0.08 155.0 0.02 94.0 1,120.0 2.0 9.53 20
<br /> 09/21/12 5,913.1 4,953,475 6,846,165 14,602 395 0.27 155.0 0.03 140.0 600.0 0.0 7.79
<br /> 10/19/12 5,921.0 4,956,380 6,849,070 2,905 104 0.07 149.8 140.0 480.0 0.0 7.65
<br /> 11/28/12 5,923.8 4,970,032 6,862,722 13,652 341 0.24 -- -- -- -- 6.82 19
<br /> 12/21/12 5,961.1 4,984,383 6,877,073 14,351 624 0.43 140.0 0.60 123.0 50.0 0.0 7.00
<br /> Current Reporting Period: September 21,2012 to December 21,2012 Cumulativie Totals: March 18,2004 to December 21,2012
<br /> Number of Hours Operated During Reporting Period: 48.0 hours Number of Days of Operation 1,600 days
<br /> Total Gallons Processed During Reporting Period: 30,908 gallons Total Gallons Extracted 6,877,073 gallons
<br /> Average Flow Rate(gpm)During Reporting Period: 0.24 gpm Average Flow Rate(gpm) 2.98 gpm
<br /> Period Percent Operational: 2%
<br /> AIIIIIIIIIIIIIIIIII
<br /> Constituent Period Vapor Period Liquid Period Total Historical Vapor Historical Liquid Historical Total
<br /> lbs. gals lbs. gals lbs. gals lbs. gals lbs. lbs. gals
<br /> SPH - 7.21 - 7.21 - - -- - 1,796
<br /> TPHd - 1.44 0.20 1.44 0.20 8.1 1.12 9,550 9,559 1,331
<br /> TPHo - -- 0.77 0.10 0.77 0.10 - - 5,142 5,142 675
<br /> TPHg 1.26 0.21 0.02 0.00 1.28 0.21 17,888 2,932 152 18,040 2,957
<br /> Benzene 0.00 0.00 0.00 0.00 0.00 0.00 12.02 1.64 0.07 12.09 1.63
<br /> MtBE 0.00 0.00 0.00 0.00 0.00 0.00 3.52 0.57 0.02 3.54 0.57
<br /> TBA -- 0.00 0.00 0.00 0.00 - - 0.53 0.53 0.08
<br /> Equation:
<br /> [Avg of consecutive(Inf Con-Eff Con) (ppmv)]
<br /> VOC Removed/day= ------------------------------------------------------ X[86.17(g/mole)]X[1 lbs/453.59 g]X[1.2641 moles/1 cf]X[Avg of consecutive flow rates(scfm)]X[60 min/hr]X[24 hr/day]
<br /> [1,000,000 parts]
<br /> Definitions:
<br /> gal=gallons scfm =standard cubic feet per minute PAH =Polycyclic Aromatic Hydrocarbons
<br /> gpm=gallons per minute VOC=Volatile Organic Compound acfm=actual cubic feet per minute
<br /> "F=degrees Fahrenheit ppmv=parts per million by volume GAC=Granular Activated Hydrocarbon
<br /> inHg=inches of Mercury gal=gallons
<br /> gpm=gallons per minute ATC=Authority to Construct
<br /> Notes:
<br /> a =System switched to operate in catalytic mode
<br /> b=System switched to operate in thermal mode.
<br /> -Column under heading VOC(Hexane)Removed(Ib/day) added 2Q10 to track removal rate of total VOCs.
<br /> 1 =VOC represented as Hexane(molecular weight 86.17)for VOC vapor mass removal rate calculation. Hexane was used because it was most representative of the lower carbon range
<br /> organics.
<br /> 2=System permitted under ATC number N-4878-1-1. Source test for air board. Extracted groundwater being held in onsite holding tank. System shut down following source test.
<br /> 3=System started for 24-hour collection of vapor PAH samples.
<br /> 4=System shut down following completion of vapor PAH sample collection. PAH results outside of ATC limits(no detectable PAHs in influent vapor stream);alternate ATC needed to operate.
<br /> 5=Approximately 5,840 gallons of groundwater stored in holding tank discharged to sanitary sewer.
<br /> 6=ATC Number N4878-1-2 issued 7/20/2004.System restarted.
<br /> I:\Tidewater\TW Stockton(P2A)\Engineering\O&M\Tables\O&M Tables 2012\4Q12\Parcel 2A OM Tables 4Q12.xlsx Page 3 of 4