Laserfiche WebLink
30 March 2021 AdvancedGeo <br /> Project No. 21-6352 AnEmployee•OwnedCompany <br /> Page 4 of 15 <br /> ADDRESS: 8678 Carey Court <br /> LOCATION: Adjacent property to east <br /> SEPTIC SYSTEM: 1) Permit date September 1978; new installation of septic system: <br /> 1,600-gallon concrete tank with two compartments, distribution box (D-Box), two 85-foot- <br /> long leach lines, and two 36-inch diameter, 25-foot-deep seepage pits; 2) Permit date <br /> January 2000; repair/addition: addition of septic system: 3,200-gallon concrete tank with <br /> four compartments, distribution box (D-Box), eight 25-foot-long leach lines, and eight 42- <br /> inch diameter, 25-foot-deep seepage pits. <br /> ADDRESS: 8623 Carey Court <br /> LOCATION: Adjacent property to south <br /> SEPTIC SYSTEM: 1) Permit date September 1979; new installation of septic system- <br /> 2,000-gallon concrete tank with two compartments, distribution box (D-Box), three 80- <br /> foot-long leach lines, and three 33-inch diameter, 25-foot-deep seepage pits. <br /> ADDRESS: 8977 Maranon Drive <br /> LOCATION: Adjacent property to North <br /> SEPTIC SYSTEM: 1) Permit date February 1974; new installation of septic system- <br /> 1,600-gallon concrete tank with two compartments, distribution box (D-Box), two 85-foot- <br /> long leach lines, and two 36-inch diameter, 25-foot-deep seepage pits. <br /> ADDRESS: 8626 Carey Court <br /> LOCATION: Approximately 200 feet to southeast <br /> SEPTIC SYSTEM: 1) Permit date June 1979; new installation of septic system: 1,800- <br /> gallon concrete tank with two compartments, distribution box (D-Box), two 90-foot-long <br /> leach lines, and two 36-inch diameter, 25-foot-deep seepage pits. <br /> ADDRESS: 8561 Carey Court <br /> LOCATION: Approximately 300 feet to south <br /> SEPTIC SYSTEM: 1) Permit date April 1980; new installation of septic system: 1,200- <br /> gallon concrete tank with two compartments, distribution box (D-Box), two 90-foot-long <br /> leach lines, and two 33-inch diameter, 25-foot-deep seepage pits. <br /> 3.6. PROPOSED MAXIMUM SEPTIC TANK USAGE ON SITE <br /> The current residence on the property has five (5) bedrooms and utilizes the existing <br /> septic system 365 days per year. The existing septic system will not be altered from the <br /> current configuration. The average and reasonable maximum usage of wastewater for a <br /> five-bedroom home by residents is 100 gallons per day (gpd) for the first bedroom and <br /> 50 gpd for each additional bedroom for a total of 300 gpd. <br /> The new proposed septic system is planned to be located in the western portion of the <br /> property over 100 feet away from the existing onsite domestic water well and the <br /> surrounding water wells. The proposed septic system will service the planned two- <br />