Laserfiche WebLink
01 April 2021 AdvancedGeo <br /> Project No. 21-6365 AnEmployte-OwWCompony <br /> Page 4 of 15 <br /> 3.5. GENERAL AREA SEPTIC PERMIT HISTORY <br /> The following is a summary of information based on new septic system installation permits <br /> currently on file with EHD. <br /> ADDRESS: 2039 Waudman Avenue <br /> LOCATION: Adjacent property to east <br /> SEPTIC SYSTEM: 1) Permit date May 1952; new installation of septic system: 840-gallon <br /> CC brick tank with two compartments, distribution box (D-Box), and one 120-foot-long <br /> leach line; 2) Permit date October 1982; repair/addition: addition of 55-foot-long leach <br /> Ione and 36-inch diameter seepage pit. <br /> ADDRESS: 2128 Lucile Avenue <br /> LOCATION: Adjacent property to north <br /> SEPTIC SYSTEM: 1) Permit date August 1964; repair/addition: addition of 30-foot-long <br /> leach line and one 33-inch diameter, 25-foot-deep seepage pit; 2) Permit date June 1972; <br /> repair/addition: replace redwood tank with 1,200-gallon concrete tank. <br /> ADDRESS: 2108 Lucile Avenue <br /> LOCATION: Adjacent property to northeast <br /> SEPTIC SYSTEM: 1) Permit date March 1965; new installation of septic system: 1,200- <br /> gallon concrete tank with two compartments, distribution box (D-Box), two 75-foot-long <br /> leach lines, and two 60-inch diameter, 12-foot-deep seepage pits. <br /> ADDRESS: 2140 Waudman Avenue <br /> LOCATION: 175 feet to southwest <br /> SEPTIC SYSTEM: 1) Permit date October 1952; new installation of septic system: 1,000- <br /> gallon CC brick tank with two compartments, distribution box (D-Box), and two 90-foot- <br /> long leach lines; 2) Permit date November 1952; new installation of septic system: 900- <br /> gallon concrete tank with two compartments, distribution box (D-Box), and two 90-foot- <br /> long leach lines. <br /> ADDRESS: 2150 Waudman Avenue <br /> LOCATION: 175 feet to southeast <br /> SEPTIC SYSTEM: 1) Permit date October 2001; new installation of septic system: 1,200- <br /> gallon concrete tank with two compartments, distribution box (D-Box), and two 100-foot- <br /> long leach lines. <br /> 3.6. PROPOSED MAXIMUM SEPTIC TANK USAGE ON SITE <br /> The current dwelling on the property has two (2) bedrooms and utilizes the existing septic <br /> system 365 days per year. The existing septic system is planned to be destroyed and <br /> replaced with a new system that the existing dwelling will utilize 365 days per year. The <br /> new system will be installed in the same general location on the property as the current <br /> system. The average and reasonable maximum usage of wastewater for a two-bedroom <br />