Laserfiche WebLink
• <br /> Geomatrix Consultants <br /> October 14,2003 <br /> Page 4 <br /> or interference. We have used arrow heads to indicate where utilities are suspected to continue along <br /> the same alignment but were traced no further due to the distance from the prescribed survey area. <br /> The utilities we detected range in length from greater than 100 feet to shorter segments less than 15 <br /> feet long.. They occur in most areas of the site, with an increased density in the vicinity of the <br /> former building foundations. These utilities may represent abandoned pipelines of various types. <br /> The majority of the utilities are shown as undifferentiated utilities,because the type of utility they <br /> represent is unknown. We did not physically observe any above ground extensions ofthese lines and <br /> therefore could not determine their type. It is unknown whether any of the detected utilities could <br /> represent sources of contamination. <br /> In a few cases,.where we suspect(but could not confirm)the type of the utility,we have shown the <br /> lines with an appropriate symbol(and question mark). For example,toward the northwest corner, <br /> trending north-south at approximately 40 Easting,we have labeled the line as a suspected product <br /> line CTT'). This is based solely on our review of a very dated and small version of a former <br /> facilities schematic, showing the trend of a main product line. Additionally, a utility trending <br /> southwest/northeast(from 2 OOE/300N to 170E/230N),provided a s imilar TC s ignature as 'the <br /> aforementioned suspected product line. For this reason,we have also labeled it a suspected product <br /> line because the survey results indicate it may be of a similar construction and depth. It is also <br /> possible that some of the undifferentiated utilities in the vicinity of the foundations may represent <br /> former product lines. However, we did not have any corroborative information to support our . <br /> speculation. <br /> We have labeled a few utilities as suspected water lines("W?")in the vicinity of 0-100 E and 200- <br /> 300N. These trend in the general direction of active residences/buildings as well as toward the"in- <br /> use"water tank. <br /> It has also been our experience that in some cases,curving,or relatively short utility segments(less <br /> than approximately 20-to-30 feet long)may in fact represent linear metal debris such as a section of <br /> railroad rail,based on their similar instrument response. <br /> Finally,a known petroleum pipeline is located outside the investigation area. It is currently marked <br /> with Kinder Morgan placards as a high pressure petroleum pipeline. It lies approximately 25-to-30 <br /> feet southwest and parallel to the railroad. <br /> Buried Metal <br /> During the course of the survey,we identified several areas of localized buried metal(based on our <br /> interpretation of the TC contour variations and MD results). These areas are shown on Plates 1 and <br /> 2 as metal detector anomalies. The type of metal debris or objects these features actually represent <br />