Attachment B: Data Usability Summary and Laboratory Chemical Analytical Report <br /> Method Blank Results <br /> All laboratory method blanks were free of contamination. <br /> Field QC Results <br /> One equipment blank and one trip blank were submitted with the field samples. The equipment <br /> rinsate and trip blank were free of contamination,with the exception of a trace concentration of <br /> TPHd in equipment rinsate blank sample QA-R-060504. TPHd were detected at 89 micrograms <br /> per liter(gg/L). The concentration is between the laboratory MDL and reporting limit, and the <br /> result was flagged J to indicate the concentration is an estimate. The lab noted that the observed <br /> chromatogram pattern is not typical of#2 fuel/diesel, and the reported result is due to groupings <br /> of peaks eluting in the TPHd range. After the silica gel-cleanup process, QA-R-060504 had a <br /> non-detect result. TPHd were only detected at a similar concentration in one associated field <br /> sample,MW-5-W-060504. The laboratory noted the chromatogram pattern for this sample also <br /> did not resemble diesel, and had a non-detect result after the silica-gel cleanup. This indicates <br /> that the results reported for the TPHd for QA-R-060504 and in MW-5-W-060504 were not due to <br /> target analytes. Therefore,the trace detection in the equipment rinsate does not indicate <br /> nonconformances with equipment decontamination procedures. <br /> Chain-of-Custody Forms <br /> Sample analytical results were evaluated for agreement with the chain-of-custody form. Based on <br /> the evaluation, all samples were received at the lab in the appropriate containers and in good <br /> condition,with the chain-of-custody form filled out properly. <br /> Preservation and Holding Times <br /> Samples were preserved in the field as appropriate,were received at the laboratory within the <br /> acceptance temperature criterion of 4+2 °C, and were prepared and analyzed within specified <br /> holding times. The sample preservations,when required by the analysis,were less than the <br /> acceptance pH limit of 2. <br /> MDLs and Reporting Limits <br /> The laboratory reported results between the MDL and reporting limit. The MDL represents the <br /> lowest concentration point where an analyte can be positively identified,but the quantitation is an <br /> estimate. The reporting limit is the lowest concentration of an analyte in a sample that a <br /> laboratory can report with precision and accuracy. Analytes that were reported between the MDL <br /> and reporting limit were flagged J as estimates. <br /> Laboratory Fuel Notes for TPHd Analysis <br /> The laboratory noted that the observed hydrocarbon fuel pattern for TPHd analysis in sample <br /> MW-7-W-060504 and its field duplicate MW-7-WD-060504 included#2 fuel/diesel and an <br /> additional pattern that elutes later in the target carbon range. TPHd were reported at 710 µg/L in <br /> sample MW-7-W-060504, and 550 µg/L in field duplicate sample MW-7-WD-060504. After <br /> silica-gel cleanup, TPHd were 52 µg/L in MW-7-W-060504 and were not detected in MW-7- <br /> WD-060504. This indicates the TPHd results were likely biased high due to biogenic material <br /> that was removed during silica-gel analysis. <br /> The laboratory noted the observed chromatogram pattern for TPHd analysis in sample MW-5-W- <br /> 060504 and equipment rinsate QA-R-060504 did not resemble#2 fuel/diesel and the reported <br /> results for the samples are due to groupings of peaks eluting in the target carbon range. After <br /> silica-gel cleanup,there were non-detect results for TPHd,which indicates the TPHd results were <br /> likely due to non-target interferences in the sample matrix. <br />