Laserfiche WebLink
DATA USABILITY SUMMARY <br /> INTRODUCTION <br /> SAIC evaluated the analytical data for the following groundwater and water-matrix quality control(QC) <br /> samples collected on April 30, 2007, at 35275 Welty Road in Vernalis, California: <br /> • QA-R-070430(equipment rinsate blank) <br /> • MW-5-W-070430 <br /> • WFSMW-I-W-070430 <br /> • WFSMW-I-W-070430MS <br /> • WFSMW-I-W-070430MSD <br /> Lancaster Laboratories, Inc.performed all the analyses on the samples. All samples were analyzed for <br /> the following constituents: <br /> • Total petroleum hydrocarbons quantified as diesel-range organics (TPHd), carbon range C10-C25, <br /> by U.S. Environmental Protection Agency(EPA)Method SW801513; a silica gel-cleanup <br /> procedure based on EPA Method SW3630 was also performed on samples with TPHd detections <br /> to remove non-target biogenic compounds; <br /> • Polynuclear aromatic hydrocarbons(PAHs)by EPA Method SW8270C with selective ion <br /> monitoring(SW8270C-SIM). <br /> The data was evaluated in general conformance to the requirements of project objectives specified in the <br /> following documents: <br /> • Quality Assurance& Quality Control:Sample Collection, Handling, and Analysis Guidelines; <br /> ChevronTexaco Historical Pipeline Portfolio Sites, California,January 2006; <br /> • SAIC Technical Procedure TP-DM-300-7,Data Validation; and <br /> • SAIC Technical Procedure TP-DM-300-14,Evaluation of Field and Analytical Data. <br /> INTENDED USES OF THE DATA <br /> Laboratory data are being used for site evaluation and decision making for petroleum releases attributed <br /> to Chevron's historical crude oil and Bunker C fuel oil pipelines. The data generated will be compared to <br /> Regional Water Quality Control Board water quality objectives and may be used for risk assessment <br /> purposes. <br /> DATA QC OBJECTIVES <br /> SAIC evaluated the project analytical data according to the following parameters in order to determine <br /> their usability: <br /> • Precision <br /> • Accuracy <br /> • Representativeness <br /> • Completeness <br /> • Comparability <br /> DATA USABILITY SUMMARY <br /> The following sections summarize the findings of the data evaluation process. The following data <br /> validation qualifiers were used in the data evaluation: <br /> ualifier Description <br /> J Indicates the reported value is an estimated concentration detected between the <br /> method detection limit(MDL)and limit of quantitation(LOQ). <br />