Mr.M. Scott Mansholt—CEMC <br /> Annual 2009 Groundwater Monitoring and Sampling Report April 3,2009 <br /> US Can-Welty Road Page 3 of 5 <br /> (SPO). MW-3 was not sampled from May 2006 until January 2008 due to <br /> insufficient water accumulation in the well. <br /> • Depth to Groundwater at Site: Ranged from 34.80 feet below top of casing <br /> (btoc) in MW-2 to 36.47 feet btoc in MW-1. Depth-to-groundwater <br /> measurements collected to date indicate that the average depth to groundwater at <br /> the site is 34.15 feet btoc. <br /> • Calculated Groundwater Elevation: Ranged from 69.91 feet above mean sea <br /> level (MSL) in MW-1 to 70.21 feet above MSL in MW-2. Groundwater elevation <br /> measurements collected to date indicate that the average groundwater elevation at <br /> the site is 71.46 feet above MSL. <br /> • Approximate Groundwater Flow Direction/Gradient: The groundwater flow <br /> direction and gradient could not be calculated due to an insufficient number of <br /> data points (less than three). Historical data for the site indicates that the <br /> groundwater flow direction is inferred to be to the east at 0.001 feet per foot. <br /> Depth to groundwater was measured in MW-1, MW-2, and MW-3 on February 11, 2009, <br /> using an oil/water interface probe. These measurements are provided in Table 1 along <br /> with historical depth-to-groundwater measurements, groundwater elevations, and product <br /> thickness. A map showing the February 2009 groundwater elevations is shown on <br /> Figure 3. Field data sheets are included as Attachment B. <br /> SAMPLING <br /> On February 11, 2009, following depth-to-groundwater measurements, MW-3 was <br /> purged using the three well casing-volume purge method due to a slow recharge rate. <br /> A disposable bailer was used for sampling. The pH, specific conductance, temperature, <br /> turbidity, and dissolved oxygen water-quality parameters were recorded during the purge <br /> process. Groundwater samples were collected at MW-3 following the three well casing- <br /> volume purge, and after the groundwater recharged to 80 percent of the static depth-to- <br /> groundwater level. Samples were not collected from MW-1 and MW-2 due to the <br /> historical presence of SPO. Samples were not collected from WFSMW-1 due to a <br /> concurrence by the RWQCB to discontinue monitoring and sampling in an August 2007 <br /> letter to CEMC2. Field data sheets are included as Attachment B. <br /> Laboratory-provided bottles were used to preserve the samples. The bottles were labeled, <br /> sealed, and placed immediately into an ice-cooled chest for delivery to Lancaster <br /> Laboratories, Inc. (Lancaster)under SAIC chain-of-custody protocol. Lancaster is a <br /> California-certified laboratory (ELAP #2116). <br /> 2. RWQCB—Central Valley Region,2007. Review of Second Quarter 2007 Groundwater Monitoring and Sampling <br /> Report—US Can-Welty Road Property,Vernalis,San Joaquin County. August 16. <br />