My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_2012-2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
14750
>
4400 - Solid Waste Program
>
PR0440007
>
CORRESPONDENCE_2012-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2025 2:23:38 PM
Creation date
6/1/2021 2:36:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
2012-2014
RECORD_ID
PR0440007
PE
4434 - LANDFILL DISPOSAL SITE - POST CLOSURE
FACILITY_ID
FA0000595
FACILITY_NAME
HARNEY LANE LANDFILL
STREET_NUMBER
14750
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06503006
CURRENT_STATUS
Active, billable
SITE_LOCATION
14750 E HARNEY LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
Site Address
14750 E HARNEY LN LODI 95240
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
227
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 1 of 3 <br /> Natalia Subbotnikova [EH] <br /> From: Robert McClellon [EH] <br /> Sent: Monday, May 20, 2013 1:14 PM <br /> To: 'DelFrate, Todd @Waterboard s' <br /> Cc: Natalia Subbotnikova [EH]; 'Michael Carroll' <br /> Subject: RE: Replacing groundwater wells at several San Joaquin County Landfills <br /> Todd, let me take a look at this. I would not approve something that did not meet 74-90 or 74-81. The driller would <br /> need to provide a 2 inch well seal. This particular issue was not covered in any conversation with Mike. If it is part <br /> of the plan then my staff reviewed it and did not catch the well seal not being large enough. I will see check and <br /> get back to you, but I can say now they would need to provide 2 inch annular seal. Robert <br /> Robert McClellon, Program Coordinator RENS <br /> Environmental Health Department <br /> 1868 E. Hazelton Ave <br /> Stockton, CA 95205-6232 <br /> Phone (209) 468-0332 <br /> Fax (209) 468-8392 <br /> From: DelFrate,Todd@Waterboards [mailto:Todd.Del Frate@waterboards.ca.gov] <br /> Sent: Monday, May 20, 2013 12:43 PM <br /> To: Robert McClellon [EH] <br /> Cc: Wyels, Wendy@Waterboards <br /> Subject: FW: Replacing groundwater wells at several San Joaquin County Landfills <br /> Hi Robert, Mike says he has gotten permission from someone down at EHD concerning the issues below. <br /> I am not trying to get involved with EHD process but I want to make that proper wells are installed. DWR <br /> Well Standards 74-90, section 9C: Radial thickness of Seal states in part:A minimum of two inches of <br /> sealing material shall be maintained between all casings and the borehole wall...At least two inches of <br /> sealing material shall also be maintained between all casings in a borehole...etc. Based on this alone, I <br /> wouldn't approve the well design. Mike is calling for a 2-inch diameter well with a 1-inch diameter well in <br /> a 6-inch diameter boring. Can you check with your staff and discuss. Let me know. Much appreciated. <br /> From: Michael Carroll [mailto:mcarroll@sjgov.org] <br /> Sent: Monday, May 20, 2013 10:36 AM <br /> To: DelFrate, Todd@Waterboards <br /> Subject: RE: Replacing groundwater wells at several San Joaquin County Landfills <br /> Hi Todd, <br /> We checked with them at the start of this process,they seem fine with it,and have approved the Plan <br /> that you received last week(figures showing diameter and two risers included). So it seems all is OK on <br /> this. <br /> Mike <br /> W.Michael Carroll,PE <br /> Phone(Direct):209-468-8504 <br /> 5/20/2013 <br />
The URL can be used to link to this page
Your browser does not support the video tag.