Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2115
>
1600 - Food Program
>
PR0527992
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2023 1:52:34 PM
Creation date
6/15/2021 4:53:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0527992
PE
1617
FACILITY_ID
FA0017819
FACILITY_NAME
CAGASOLINE INC
STREET_NUMBER
2115
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
2115 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXISTING <br /> 120/208 VOLTS 3 PHASE 4 WIRE MAIN MOUNTING i°� K2-3 K2-36 <br /> PANE C npE LOAD CENTER gUS 100 CBS ONLY SURFACE <br /> 0 0 0IL o K2-22 K2-24 <br /> CKT. LOAD DESCRIPTION (D u BRKR J PHASE KVA LOAD J BRKR c� LOAD DESCRIPTION CKT. J EXISTIN(�EtECTFUCAL � - - - <br /> N0. & LOCATION J P T J 4A GB bC J P T J & LOCATION NO. PANELS AND - � WALK-IN L_ - - J <br /> 1 E REC-MONEY ORDER 1 20 0.2/0.6 1 20 E REC-TEAL CONDITIONE 2 WORKROOM O o <br /> OFFICE CONTROLS COOLER <br /> 3 E REC-LOTTO MACH 1 20 0.5/0.2 1 20 E REC-SAFE 4 106 107 105 <br /> e n g in e e r i n g <br /> 5 (E) OFFICE IG 1 20 0.4 0.2 1 20 (E) REC-ATM 6 L H B & A ssociates, Ltd. <br /> 7 E OFFICE IG 1 20 0.4 0.4 1 20 (E) INTERCOM 8 _1 -2/4 K2-22 K2-24 K2- <br /> 9 (E) SITE CONTROLLER 1 20 1.0 1.0 1 20 (E) ALLIED BOX 10 -30P °o° PO Box 1205 <br /> 11 (E) TLS 350 1 20 1.0/1.0 1 20 (E) OVERFILL ALARM 12 San Luis Obispo,CA 93406 <br /> - - - - - - - - - li)u <br /> - - - - - - - - - - - - ph 805.540.5240 <br /> 1 �- /3 7 9 1-1 ,A� al � -5 K1-21 K1-2 K1- 9 L-2 -2 <br /> 15 1 6 C-4 <br /> 17 18 R ® I <br /> 19 20 -1 I F- -1 <br /> 21 22 I <br /> 23 24 CASHIER <br /> 25 26 102 KII L -1 PROFESS/p <br /> 27 28 g �l <br /> I <br /> 0 <br /> 29 30 C I O¢Q. <br /> 31 32 - _ _ _ _ Z <br /> z p F w No.78916 n <br /> HORC <br /> 35 36 � O K2-14 COND�T� <br /> 37 38 co <br /> z = K2-16 <br /> 40 U - � <br /> 39 ~ K2-19 - K2-15 K2- 3 X44-4 -K4-4 <br /> MIN. CB INTER. CAP. SUB TOTALS 1.6 2.7 2.6 w LL January 24, 2021 <br /> 10,000 AMPS TOTAL CONNECTED LOADS 6.6 KVA+ LCL KVAx25% = 6.6 KVA= 18 AMPS <br /> [ CONSULTANTS <br /> C <br /> SALES <br /> EXISTING a NOTES: 101 K1-15/17 <br /> PANEL K 1 120/208 VOLTS 3 PHASE 4 WIRE MAIN MOUNTING 1. REFER TO EQUIPMENT/FIXTURE PLANS FOR K1-26 6-20P K2_8 <br /> TYPE <br /> BUS 250 LUBGS ONLY FLUSHSURFACE - ADDITIONAL INFORMATION FOR CABINETRY, D <br /> FIXTURES, AND EQUIPMENT, SHEET EF1.0. <br /> cD u BRKR - PHASE KVA LOAD _j BRKR c� v '�C - 2-DOOR FREEZEO <br /> CKT. LOAD DESCRIPTION w v v w LOAD DESCRIPTION CKT. 2. INTENT IS TO REUSE EXISTING CIRCUITRY 14-20P <br /> NO. & LOCATION J o- P T J DA DB OC J P T J & LOCATION NO. RECEPTACLE TO BE I DUAL VOLTAGE <br /> N N COFFEE 1-DR ICE MERCH.COND LOCATIONS AS MUCH AS FEASIBLE. K2-1 120/208-230V <br /> 1 ( ) 2 20 2.8 2.0 2 30 2 3. IT IS CONTRACTOR RESPONSIBILITY TO ABANDONED oO <br /> 2.8 2.0 -18 ENSURE EQUIPMENT IS CONNECTED TO - PROVIDE COVER <br /> N 5 N ICE COFFEE DISP 1 20 0.1 2.8 0� ELECTRICAL CIRCUITRY FOR PROPER PLATE <br /> N 7 (N) COFFEE 2 20 3.0/2.8 3 30 2-DR LT FRZR CS COND 8 K2 0 11 OPERATION. o icN o <br /> N 11 (N) 2-DOOR FREEZER 2 20 1.1 /1.7 2 30 (N) ICEMAKER COND 12 <br /> 1.1 /1.7 <br /> N 15 (N) DELI ISLAND 2 30 0.1/0.2 1 20 DOOR BUZZER 16 <br /> 0.17-0 - <br /> .2 1 20 N SPARE 18 <br /> N 19 (N) 2-DOOR FREEZER 1 20 0.6 0.2 1 20 (N) SPARE 20L _ _ _ J WOMEN MEN <br /> 21 REC-GENERAL 1 20 0.4 1 20 SPARE 22 - - - - - - - - - 103 104 <br /> 23 SPARE 1 20 1 20 SPARE 24 - - - - - - _ _ - - - - - - <br /> - - - - REVISIONS <br /> 25 SPARE 1 20 0.7 1 20 N ISLAND DELI 26 N - - - - - - - - - - - - - _ _ _ _ - _ _ - - - - - - - - - - - <br /> 27 (N) COFFEE CREAMER 1 1 120, 1 20 1 (N) FROSTER EXH. FAN 28 N <br /> N 29 (N) FREEZER 1 20 3.0/1.7 1 20 N SPARE 30 N 0 4' 8' 12' <br /> N 31 SPARE 1 20 0.2 0.7 1 20 (N) CAPPUCINO 32 N POWER FLOOR P LAN <br /> N 33 (N) COFFEE 2 20 0.8 1 20 SPARE 34 SCALE: 1/4" - V-0" NORTH <br /> 0.8 1 20 SPARE 36 <br /> 37 SPARE 1 20 1 20 SPARE 38 <br /> 39 SPARE 2 70 0.2 1 20 N REC-POS 40 <br /> U. 1 20 N REC-POS 42 <br /> MIN. CB INTER. CAP. SUB TOTALS 18.4 15.6 11.7 <br /> 10,000 AMPS ITOTAL CONNECTED LOADS 45.7 KVA+ LCL KVAx25% = 45.7 KVA= 127 AMPS SUBMITTAL DATES <br /> N = PROVIDE NEW BREAKER AS SHOWN O O <br /> O O OWNER: <br /> EXISTING #10 01/18/2021 <br /> 120/208 VOLTS 3 PHASE 4 WIRE MAIN MOUNTING n K2-34 AC REG. AGENCIES <br /> PANEL K 2 1 [� 01/18/2021 <br /> TYPE BUS 250 LUGS ONLY SURFACE EXISTING GFCI PROTECTED RECEPTACLE <br /> CB FLUSH INSTALLED WITHIN 25 FEET OF ALL NEW HVAC #10 K1-12/14 O.T.B.: <br /> CKT. LOAD DESCRIPTION cD c) BRKR PHASE KVA LOAD BRKR cD LOAD DESCRIPTION CKT. -- <br /> w c� c� w AND VENTILATION EQUIPMENT ON THE ROOF <br /> NO. & LOCATION J o' P T J OA OB OC J P T J & LOCATION NO. - 15 AND 20 AMPERE, 125 AND 250 VOLT LC <br /> 1 (E) WALK-IN LIGHTS 1 20 1.0/2.8 2 40 (N) UNOX OVEN 2 RECEPTACLES INSTALLED IN A WET LOCATION EXISTING HVAC UNIT EXISTING WALK-IN PROJECT NO. <br /> 3 REC-WORK STATION 1 20 0,272.8 <br /> HAVE AN ENCLOSURE THAT IS WEATHERPROOF K2-21 ____-ABANDON OR DEMO COOLER REMOTE 15-13-008 <br /> 5 SPARE 1 20 1.0/0.5 1 20 SPARE 6 WHETHER OR NOT THE ATTACHMENT PLUG CAP F_ ��-- EXISTING REMOTE CONDENSERS DRAWN BY: <br /> 7 CCTV MONITORS 1 20 0.2 1.8 1 20 REC-ICE MACH 8 IS INSERTED -1 CONDENSER IF NOT NEEDED F_ AFS <br /> 9 (E) CONVENIENCE 1 20 0.6/1.8 1 20 N 2-DOOR FREEZER 10 #10 K1-28 -COORDINATE WITH <br /> CHECKED BY: <br /> 11 (E) FRONT DOOR 1 20 0.2/0.5 1 20 (N) REC-HORCHATA 12 O JRB OWNERS REPRESENTATIVE <br /> 13 (N) REC-PIZZA 1 20 1.1 0.8 1 20 N REC-SODA DISP 14 <br /> 15 (N) REC-HEATED MERCH 1 20 1.5/0.4 1 20 N REC-ICE MACHINE 16 r <br /> 17 N REC-HOT DOG ROL 1 20 1.0/0.4 1 20 (N) FREAL 18 <br /> E - <br /> 19 N REC-REF. COND. 1 20 0.4 0.5 1 20 (E) FLY FAN 20 <br /> 21 (E) REC-ROOF 1 20 1.0/0.4 1 20 N REC-OFFICE 22 N <br /> 23 REC-WORK STATION 1 20 0.2 0.4 1 20 (N) REC-OFFICE 24 N <br /> 25 REC-WORK STATION 1 20 0.2/0.2 2 30 (N) FROSTERS 26 N PROVIDE%4" EMPTY CONDUIT WITH PULL �'�ABANDON OR DEMO <br /> 27 (E) REC-SHOW WINDOW 1 201 1.0/0.2 CHORD STUBBED INTO CEILING SPACE FOR EXISTING REMOTE rr Vrr�� <br /> 29 SPARE 1 20 0.5 1 20 (N) FREAL 30 CONTROLS CONDENSER IF NOT NEEDED LU ~ <br /> 31 SPARE 1 20 1.0/0.2 1 20 (N) REC-ICE MAKER 32 N -TYPICAL - <br /> COORDINATE WITH z Z cy) <br /> 33 MICROWAVE 2 20 0.8 0.2 1 20 (N) ICE MAKER REMOTE 34 N OWNERS REPRESENTATIVE - w o <br /> 0.8 0.7 1 20 REC-FREEZER 36 Q > <br /> 37 N SPARE 1 20 0.2/3.0 1 20 N SPARE 1 38 U 1 z Q Q <br /> 39 (E) W.I. COOLER CONDENS. 3 40 3.0 3.0 3.0 3.0 3 40 (E) W.I. COOLER CONDENS. 40 EXISTING MAIN SWITCHBOARD 0 8' 16' 24' J z0 <br /> MIN. CB INTER. CAP. SUB TOTALS 16.2 16.5 1 1.7 1200 AMP 120/208V 3�, 4W POWER ROOF PLAN z U m LU0� 2i LL <br /> NEMA 3R SCALE: 1/8" = V-0" NORTH Q w U) J <br /> 10,000 AMPS TOTAL CONNECTED LOADS 44.4 KVA+ LCL KVAx25% = 44.4 KVA= 123 AMPS EXIST CT COMPARTMENT (E) (E) (E) (E) O Q <br /> N = PROVIDE NEW BREAKER AS SHOWN WITH SOCKET, WH SEWER STORM � U <br /> U <br /> TESTBLOCK AND BYPASS 1 (E) LIFT LIFT ~ Q <br /> EXISTING PER LOCAL UTILITY PANEL LEGEND <br /> REQUIREMENTS (E) (E) (E) (E) W LU <br /> U <br /> 120/208 VOLTS 3 PHASE 4 WIRE MAIN MOUNTING PANEL PANEL PANEL PANEL »S�, AC � <br /> PANEL L LUGS ONLY SURFACE M "L" "K1" "K2" "C" � � DUPLEX RECEPTACLE, 125V, 20A, 3PG, +18" UON °' � Q <br /> TYPE BUS 250 LU FLUSH 2 <br /> CKT. LOAD DESCRIPTION cD w BRKR _j PHASE KVA LOAD _j BRKR w LOAD DESCRIPTION CKT. (E) 225/3 (E) (E) FEEDER F F F 0 4-PLEX RECEPTACLE, 125V, 20A, 3PG, +18" LION N <br /> N0. & LOCATION J � P T J �A �B OC J P T J � & LOCATION N0. 1200/3 n (E) (E) (E) ® 208V OUTLET, +18" UON <br /> 1 (E) LTS-SALES 1 20 1.0 0.2 1 20 (E) CIGARETE MERCH 2 225/3 (E) (E) FEEDER <br /> 3 (E) LTS-BACK/OFFICE 1 20 1.0 0.2 1 20 (E) BNB SYRUP 4 EXIST PULL SECTION n s.. <br /> 5 (E) LTS-SALES 1 20 1.0/0.8 1 20 (E) LTS-SALES 6 PER LOCAL UTILITY 225/3 CO. REQUIREMENTS (E) (E) FEEDER TELEPHONE/DATA OUTLET WITH 4 CONDUIT TO <br /> ABOVE ACCESSIBLE CEILING <br /> 7 (E) LTS-EXTERIOR 1 20 1.0/0.1 1 20 (E) LTS-EMERGENCY 8 - <br /> 9 (E) LTS-SALES 1 20 0.2 1 20 WALL CLOCK 10 100/3 (E) (E) FEEDER DISCONNECT SWITCH ,TYPE AND RATING AS <br /> 11 (E) CO2 MONITOR 1 20 0.2 1.2 1 20 (E SIGN CARWASH 12 REQUIRED w <br /> 13 SPARE 1 20 1.0 1 20 (E) LTS CARWASH 14 40/3 (E) (E) FEEDER <br /> n q SHEET TITLE <br /> 15 SPARE 1 .20. 71 20 SPARE 16 co <br /> 17 SPARE1 20 1 20 SPARE 18 100/3 (E) (E) FEEDER GENERAL NOTES CD <br /> 19 SPARE 1 20 <br /> 1 20 SPARE 20 POWER PLANS <br /> 21 SPARE 1 20 1.2 1 20 (E) SIGN STORE FRONT 22 70%3 (E) (E) FEEDER 1. CONTRACTOR SHALL VISIT JOBSITE AND THOROUGHLY EXAMINE ALL EXISTING CONDITIONS WHICH y , <br /> 23 SPARE 1 20 1.0 1 20 E FLY FAN 24 30 3 E MAY AFFECT THEIR WORK PRIOR TO SUBMITTING BID. NO ADDITIONAL COSTS WILL BE CONSIDERED <br /> ( > / ( ) (E) FEEDER FOR CONTRACTORS FOR FAILURE TO DO SO. REPORT ANY DISCREPANCIES OR PROBLEMS 0ONE LINE <br /> 25 (E) CANOPY LED 1 20 0.5 1 20 SPARE 26 �� ENCOUNTERED TO ENGINEER. o <br /> 27 (E) CANOPY LED 1 20 0.5 1.2 1 20 (E SIGN-ID/PRICE 28 30/3 (E) (E) FEEDER ' DIAGRAM AND <br /> 29 (E) CANOPY LED 1 20 0.5/1.2 1 20 (E) SIGN-ID/PRICE 30 �� 2. CONTRACTOR TO VERIFY ALL CIRCUITS. <br /> 31 SPARE 1 20 1.0 2 20 (E) LTS-PARKING 32 SPACE (E) 3. ALL SWITCHBOARDS, PANEL BOARDS, INDUSTRIAL CONTROL PANELS AND MOTOR CONTROL PANEL <br /> 33 (E) BUILDING SIGN 1 20 1.2 1.O CENTERS SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ARC FLASH 2 <br /> 35 (E) CANOPY LIGHTS 2 30 1.0 1 20 SPARE 36 1 HAZARDS AND THE APPROPRIATE PRE REQUIRED PER 2019 CEC 110 16 AND NFPA-70E-2000. ;z SCHEDULES <br /> cl <br /> 1.0/1.0 1 20 SPARE 38 4. PROVIDE HANDLE TIE FOR MULTIWIRE CIRCUITS PER 2019 CEC 210.4(C). <br /> 39 (E) CANOPY LIGHTS 2 30 1.0 1.0 2 20 (E) LTS-CANOPY 40 S EXIST #3/0 CU GROUNDING NOTES: cc <br /> 1.0 1.0 ELECTRODE CONDUCTOR 5. ALL FEEDERS SHALL BE COPPER. co <br /> MIN. CB INTER. CAP. SUB TOTALS 6.8 8.5 8.9 1. ALL ITEMS SHOWN ARE EXIST. UON. <br /> 6. USE EXISTING SPARE CIRCUITS FOR NEW OR RELOCATED ELECTRICAL ITEMS IF SPARE CIRCUIT IS Y <br /> 10,000 AMPS ITOTAL CONNECTED LOADS 24.2 KVA+ 21.6 LCL KVAx25% = 29.6 KVA= 82 AMPS EXIST EXIST GROUND ROD 2. EXIST AIC = 65000 AMPS SYM. NOT AVAILABLE,INSTALL NEW BREAKER IN EXISTING SPACE. <br /> SECONDARY EXIST0 CU GROUNDING 3 a SHEET NO. <br /> # / 7. TEST, REPAIR,OR REPLACE ANY DEFECTIVE CIRCUIT BREAKERS IN ALL PANEL BOARDS. <br /> ELECTRODE CONDUCTORCL <br /> J <br /> 8. PROVIDE NEW TYPEWRITTEN PANEL BOARD DIRECTORIES FOR ALL BRANCH CIRCUIT PANEL BOARDS o <br /> EXIST THE MAIN PANEL GROUND TO AFFECTED BY THIS EQUIPMENT REPLACEMENT WHETHER NEW OR EXISTING. E1 . 0 <br /> GROUND ROD OR UFER AND METALLIC <br /> WATER PIPE SHALL BE WITHIN 5 FEET 9. MANTECA MUNICIPAL CODE 15.20.070 ADD CEC ARTICLE 334.12(A)(11):IN BUILDING USED FOR <br /> OF BUILDING ENTRANCE IN SINGLE LINE DIAGRAM COMMERCIAL OR INDUSTRIAL PURPOSES,NONMETALLIC SHEATHEED CABLE TYPES NM,NMC OR NMS <br /> SHALL NOT BE INSTALLED. <br /> ACCORDANCE WITH NEC 250-50 <br /> SCALE: NONE <br />