Laserfiche WebLink
03 June 2021 vne <br />Project No. 21-6431 An Employee Owned Company <br />Page 4 of 15 <br />.1 <br />3.5. GENERAL AREA SEPTIC PERMIT HISTORY <br />The following is a summary of information based on new septic system installation permits <br />currently on file with EHD. <br />ADDRESS: 6115 Garnica Court <br />LOCATION: Adjacent property to east <br />SEPTIC SYSTEM: 1) Permit date April 1990; new installation of septic system: 1,600 - <br />gallon concrete tank with two compartments, distribution box (D -Box), two 85 -foot -long <br />leach lines, and two 36 -inch diameter, 25 -foot -deep seepage pits; 2) Permit date January <br />2000; repair/addition: addition of septic system: 3,200 -gallon concrete tank with four <br />compartments, distribution box (D -Box), eight 25 -foot -long leach lines, and eight 42 -inch <br />diameter, 25 -foot -deep seepage pits. <br />ADDRESS: 1412 Garnica Drive <br />LOCATION: Adjacent property to west <br />SEPTIC SYSTEM: 1) Permit date November 1981; new installation of septic system: <br />2,000 -gallon concrete tank with two compartments, distribution box (D -Box), three 80 - <br />foot -long leach lines, and three 33 -inch diameter, 25 -foot -deep seepage pits. <br />ADDRESS: 6050 Garnica Court <br />LOCATION: Adjacent property to the south <br />SEPTIC SYSTEM: 1) Permit date May 1988; new installation of septic system: 1,200 - <br />gallon concrete tank with two compartments, distribution box (D -Box), two 85 -foot -long <br />leach lines, and two 33 -inch diameter, 25 -foot -deep seepage pits. <br />ADDRESS: 6110 Garnica Court <br />LOCATION: Approximately 200 feet to southeast <br />SEPTIC SYSTEM: 1) Permit date November 1989; new installation of septic system: <br />1,900 -gallon concrete tank with two compartments, distribution box (D -Box), two 85 -foot - <br />long leach lines, and two 36 -inch diameter, 25 -foot -deep seepage pits. <br />ADDRESS: 1520 White Lane <br />LOCATION: Adjacent property to the north <br />SEPTIC SYSTEM: 1) Permit date August 1963; additions to existing septic system: one <br />25-foot-lomg leach line. 2) Permit date September 1974; additions to existing septic <br />system: one 1,200 -gallon tank. Permit date October 2003; repairs and additions to <br />existing septic system: one 1,200 -gallon tank with 2 compartments, two 95 -foot leach <br />lines, and two 36 -inch diameter, 25 -foot -deep seepage pits. <br />3.6. PROPOSED MAXIMUM SEPTIC TANK USAGE ON SITE <br />The current residence on the property has four (4) bedrooms and utilizes the existing <br />septic system 365 days per year. The existing septic system will not be altered from the <br />