Laserfiche WebLink
adjoining properties in sufficient detail to identify how grade changes will conform to the <br /> requirements of the code . <br /> 3 . The required plans must be complete at the time of submittal for a building permit . Plans must <br /> address building design and construction , fire and life safety requirements , accessibility and <br /> show compliance with the current California codes and San Joaquin County ordinances . A <br /> complete set of plans must include fire sprinkler plans , truss design submittals , metal building <br /> shop drawings , structural plans and calculations , plumbing , electrical and mechanical drawings <br /> and energy report . <br /> 4 . A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix § J104 <br /> for grading . All recommendations of the Soils Report shall be incorporated into the construction <br /> drawings . <br /> 5 . For each proposed new building , provide the following information on the plans : <br /> a . Description of proposed use <br /> b . Existing and proposed occupancy Groups <br /> c . Type of construction <br /> d . Sprinklers (Yes or No <br /> e . Number of stories <br /> f . Building height <br /> g . Allowable floor area <br /> h . Proposed floor area <br /> i . Occupant load based on the CBC <br /> j . Occupant load based on the CPC <br /> 6 . For each existing building . The proposed use of the existing buildings will constitute a change <br /> of occupancy . A change of occupancy will require a code analysis report and necessary plans <br /> prepared by an architect or engineer in accordance with the California Existing Building Code . <br /> The report and plans shall identify existing conditions , propose alterations necessary to bring <br /> the building in compliance with the current code and include the following : <br /> a . Description of proposed use <br /> b . Existing and proposed Occupancy Groups <br /> c . Type of construction <br /> d . Sprinklers (Yes or No ) <br /> e . Number of stories <br /> f. Building height <br /> g . Allowable floor area <br /> h . Proposed floor area <br /> i . Occupant load based on the CBC for the new use <br /> j . Occupant load based on the CPC for the new use <br /> k . Risk Category analysis . (Agricultural Buildings are allowed to be constructed to Risk <br /> Category I , whereas other occupancies require Risk Category II or II . ) <br /> Modifications to existing buildings are required to include upgrades related to disability access <br /> pursuant to the California Existing Building Code . Plans showing these upgrades must be <br /> prepared by a registered engineer or licensed architect and shall be submitted for review . <br /> 7 . If high piled combustible storage is to be used in any building , an automatic fire sprinkler <br /> system ( s ) will be required . <br /> 8 . Accessible routes shall be provided per CBC § 11 B -206 . At least one accessible route shall be <br /> provided within the site from accessible parking spaces and accessible passenger loading <br /> zones ; public streets and sidewalks ; and public transportation stops to the accessible building <br /> or facility entrance they serve . Where more than one route is provided , all routes must be <br /> accessible . § 1113 "o 206 . 2 . 1 . Where improvements are made an no public transportation <br /> services nor sidewalks are provided , the accessible route shall terminate at an area of safe <br />