My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4501
>
2300 - Underground Storage Tank Program
>
PR0231233
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2021 4:48:16 PM
Creation date
8/16/2021 2:14:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231233
PE
2361
FACILITY_ID
FA0002479
FACILITY_NAME
7-ELEVEN INC #17334
STREET_NUMBER
4501
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11017004
CURRENT_STATUS
01
SITE_LOCATION
4501 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CAUTION: Integrity testing with air,gas or water can be dan- NOTICE: During pressurizing,check the reading on the inter- <br /> gerous and it is very important that the proper testing equip- stitial test gauge that should be securely connected to the <br /> ment be used and that the testing procedures be adhered to. Interstitial Test Tube.Any increase in pressure will indicate a <br /> OPW-FCS assumes no responsibility or liability for the conse- leak in the primary pipe or Fittings. <br /> quences of any testing practices.Only qualified and experi- NOTICE:All testing requirements must be in accordance with <br /> enced personnel should conduct the air pressure testing. all applicable codes. <br /> Never disconnect couplings,caps,or plugs unless the air <br /> pressure has been released. CAUTION: Always make sure the underground storage tank <br /> and dispensers are isolated from the piping system when <br /> NOTICE:All testing requirements must be in accordance with conducting pipe pressure tests. <br /> all applicable codes. <br /> CAUTION: Always make sure the underground storage tank 11.0 Routine Maintenance and Visual Inspections <br /> and dispensers are isolated from the piping system when OPW-FCS recommends routine(at least once a month)visual <br /> conducting pressure tests. inspections inside all containment sumps.Fuel leaks collected in <br /> containment sumps must be reported immediately and investigated <br /> NOTICE:Significant temperature changes can result in a pres by the site owner. If leakage or damage to the piping system is <br /> sure reading differential. suspected,OPW-FCS must be notified immediately. <br /> 10.1 Primary Pressure Testing All sumps must be kept free of fuel,water and debris.When Chang- <br /> • Pre Backfill Pressure Testing: Before backfilling of the ing fuel filters at the dispenser,make sure any spilled product is <br /> pipe,an air pressure hold&soap test is required. Pressurize cleaned out of the bottom of the dispenser sump to prevent a pos- <br /> the primary pipe to sixty pounds per square inch(60 PSI). sible fire hazard. <br /> Gradually apply air pressure into the flexible piping line and CAUTION: Ignoring or disabling leak detection alarms can <br /> maintain this pressure for a minimum of 1 hour,or in accord- lead to further damage and possible failure of the system. <br /> ance with the authority having jurisdiction(AHJ),prior to <br /> backfilling. CAUTION:Failure to remove fuel and liquids from containment <br /> sumps may compromise the performance and integrity of the <br /> • Post Backfill Air Pressure Testing: After backfilling,if the sump and its associated fittings and seals over prolonged <br /> pressure on the primary was released,an additional air pres- periods of time. <br /> sure hold test is required.Pressurize the primary pipe to sixty 12.0 Warranty Registration <br /> pounds per square inch(60 PSI).Gradually apply air pres- <br /> sure into the flexible piping line and maintain this pressure for Warranty registration must be completed and mailed to OPW-FCS <br /> a minimum of 1 hour,or in accordance with the authority for warranty activation.A copy of the warranty registration should <br /> having jurisdiction(AHJ),making sure that there is no drop in be given to the site owner for their records. <br /> pressure. 13.0 OPW-FCS Contact <br /> 10.2 Secondary Pressure Testing OPW-FCS can be contacted if there are any questions concerning <br /> • Pre Backfill Air Pressure Testing: After the primary line the installation,maintenance or repair of FlexWorks piping.Addi- <br /> pressure stabilizes,gradually apply air pressure into the inter- tional publications are also available on OPW-FCS's website <br /> stitial space of the flexible piping line. Do not exceed ten www.opwglobal.com or upon request. <br /> pounds per square inch(10psi)or 69kPa,making sure there <br /> is no drop in pressure for a minimum of one hour,or in ac- <br /> cordance with the authority having jurisdiction(AHJ). <br /> • Post Backfill Air Pressure Testing: After backfilling an air <br /> pressure hold test is required. After the primary has held <br /> pressure steadily for at least 1 hour,gradually apply air pres- <br /> sure to the secondary test tube,not to exceed 10 PSI.Main- <br /> tain this pressure for a minimum of 1 hour,or in accordance <br /> with the authority having jurisdiction(AHJ),making sure that <br /> there is no drop or increase in pressure. <br /> 3250 U70.Business West <br /> 4c> �_� Smithfieldd,N.C.,27577-0330 1=31 Vve <br /> c�=-F Customer Service:1-(800)422-2525 <br /> FUELING CONTAINMENT SYSTEMS Technical Service and Questions: 1-(877)OPW-TECH <br /> www.opwglobal.com <br /> Notice:OPW-FCS products must be used in compliance with applicable federal,state,provincial and local laws and regulations.Product selection should be based on physical specifications and limitations and compatibility with the environ- <br /> ment and material to be handled.OPW-FCS makes no warranty of fitness for a particular use.All illustrations and specifications in this literature are based on the latest production information available at the time of publication.Prices,materials <br /> and specifications are subject to change at any time,and models may be discontinued at any time,in either case,without notice or obligation.For complete OPW-FCS warranty information,visit our web site at www.opwglobal.cam. <br />
The URL can be used to link to this page
Your browser does not support the video tag.