4. Wait until the vacuum level drops to 10" Hg or less. <br /> 5. Repeat steps 2 through 4 until the vacuum level stabilizes for 5 minutes at <br /> any level between 10" Hg and 15" Hg <br /> 6. If the vacuum level is more than 10" Hg, open the valve slightly until the <br /> vacuum level is between 9.5 and 10" Hg. <br /> 7. Record the vacuum level and the time <br /> 8. Hold the vacuum for the period of time shown in the following table for the <br /> particular tank size being tested. <br /> CSI Tank Capacity * Hold Time <br /> Up to 15,000 gallons 45minutes <br /> Over 15,000 and up to 20,000 gallons 1 hours 45 minutes <br /> Over 20,000 and up to 30,000 gallons 2 hours 45 minutes <br /> Over 30,000 gallons and up to 50,000 gallons 4 hours 45 minutes <br /> * This is the total tank capacity. For a compartment tank, it is the <br /> combined capacity of all compartments. <br /> 9. If the vacuum level has dropped more than 2" Hg from the starting vacuum <br /> level recorded in step 7, continue to hold the vacuum until the total vacuum <br /> hold time equals the time shown in the following table: <br /> CSI Tank Capacity * Total Hold Time ** <br /> U to 15,000 gallons 1 hour 45 minutes <br /> Over 15,000 and up to 20,000 gallons 4 hours <br /> Over 20,000 and up to 30,000 gallons 6 hours 15 minutes <br /> Over 30,000 gallons and up to 50,000 gallons 10 hours 45 minutes <br /> * This is the total tank capacity. For a compartment tank, it is the <br /> combined capacity of all compartments. <br /> ** This time includes the hold time in step 8. <br /> 10. If the vacuum level has dropped 4" Hg or less from the starting vacuum level <br /> recorded in step 7, the annular space is airtight and no additional testing is <br /> required. <br /> If the vacuum level has dropped more than 4" Hg from the starting vacuum <br /> level recorded in step 7, check that the testing connections are airtight and <br /> repeat this procedure starting with step 2. <br /> If the tank fails to hold a vacuum that is 4" Hg or less from the starting <br /> vacuum level recorded in step 7 after repeating this procedure, contact the <br /> tank manufacturer. <br /> 02/23/01 <br />