My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0014337
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
4860
>
2600 - Land Use Program
>
PA-2100168
>
SU0014337
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/5/2023 8:42:36 AM
Creation date
8/20/2021 8:52:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0014337
PE
2687
FACILITY_NAME
PA-2100168
STREET_NUMBER
4860
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95215-
APN
17321014
ENTERED_DATE
8/10/2021 12:00:00 AM
SITE_LOCATION
4860 E MAIN ST
RECEIVED_DATE
3/3/2023 12:00:00 AM
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Goulart, Alisa [CDD] <br />From: Phil Simon <Phil,Simon@stocktonca.gov> <br />Sent: Monday, September 27,20212:39 PM <br />To: Goulart, Alisa [CDD] <br />Subject: PA -210068 (GP) / PA -21-00169 QR) / PA -2100170 (SA) - Stockton Fire Department <br />Review Comments - 4860 E. Main Street (Solari Ranch Station) <br />CAUTION: This email is originated from outside of the organization. Do not click links or open attachments unless you recognize the <br />sender and know the content is safe. <br />Hi Alisa, <br />My apologies fora late response. I have reviewed the proposed project. The following fire review comments would be <br />applicable: <br />• The site will require evaluation for off-site (public) utility improvements along the frontage of Main Street and <br />Miwuk Village Drive. This is specific to having fire hydrants installed along the frontage of the property. Fire <br />hydrants are required at every 300 feet apart. An off-site utility plan will be required for this project. The <br />Stockton Fire Department will be involved with the review of the off-site plan. <br />• On-site improvements shall also include fire hydrants for the proposed cul-de-sac area and parking lot. The Fire <br />Department will require review of the on-site utility plans as well. <br />• The Stockton Fire Department requests that the civil design team for the project engage with Fire Prevention <br />staff to determine best placement for off-site and on-site fire hydrants. <br />• Fire lane dedication shall be provided in the proposed new cul-de-sac and within the parking lot area. The <br />Stockton Fire Department will identify those areas upon time of plan check review. <br />• Based on the proposed building area, use and occupancy classification (assembly), the building will require an <br />automatic fire sprinkler system designed and installed per NFPA 13 Standards. <br />• Based on the proposed building area, use and occupancy classification (assembly), the building will require a <br />manual fire alarm system, if the occupantload exceeds 300 persons. <br />• Portable fire extinguishers will be required throughout the building. <br />• Building exiting shall meet CBC and CFC Chapter 10. <br />• Occupant loads shall be properly calculated. A sign shall be posted in areas required by the CBC and/or CFC. <br />• Deferred submittals will be required to the Stockton Fire Department for the following: Underground fire line <br />utilities, overhead fire sprinklers, and fire alarm system. <br />• Building and site work plans shall also be submitted to the Stockton Fire Department for review and approval. <br />• Once the building is completed with construction and Certificate of Occupancy has been granted, the Stockton <br />Fire Department will issue an operational fire permit for Place of Assembly. <br />Please contact me if there are any other questions. Thanks. <br />Phil Simon <br />Assistant Fire Marshal <br />Port District Fire Marshal <br />Fire Prevention Division <br />Stockton Fire Department <br />phil.simonfstockto nca.aov <br />(209) 937-8271 (Office) <br />(209) 598-8819 (Mobile) <br />Planning Commission Staff Report, PA -2100168, -169, -170 (GP, ZR, SA) 15 <br />Response Letters <br />