COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
1333
>
2800 - Aboveground Petroleum Storage Program
>
PR0528795
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2021 8:14:06 AM
Creation date
8/23/2021 11:03:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0528795
PE
2832
FACILITY_ID
FA0005630
FACILITY_NAME
CENTRAL VALLEY WASTE SERVICES
STREET_NUMBER
1333
Direction
E
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95241
APN
04908045
CURRENT_STATUS
01
SITE_LOCATION
1333 E TURNER RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Aboveground Petroleum Storage Act Inspection Report <br />Date: <br />August 17, 2021 <br /> Facility Address: <br /> 1333 E TURNER RD, LODI <br /> Facility Name: <br /> CENTRAL VALLEY WASTE SERVICES <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 712 CFR 112.7(e), 112.8(c)(6) Failed to perform scheduled tank tests or inspections by appropriately qualified <br />personnel. <br />OBSERVATION: Facility failed to ensure that tanks are inspected and tested by an appropriately qualified person in <br />accordance with industry standards. The following observations were noted: <br />-Monthly and annual inspections are not being conducted for the 600 gallon and 241 gallon balers <br />-Monthly inspections for the 500 gallon oil tanks and 1000 gallon used oil tank are being done on the portable <br />container inspection report instead of the tank monthly inspection report <br />-The 1/8/2016 formal STI SP001 inspection report required the 12,000 gallon diesel tank to be formally inspected <br />again in 5 years. This inspection has not been completed. <br />REGULATION GUIDANCE: 112.8(c)(6) Test or inspect each aboveground container for integrity on a regular <br />schedule and whenever you make material repairs. You must determine, in accordance with industry standards, the <br />appropriate qualifications for personnel performing tests and inspections, the frequency and type of testing and <br />inspections, which take into account container size, configuration, and design (such as containers that are: <br />shop-built, field-erected, skid-mounted, elevated, equipped with a liner, double-walled, or partially buried). Examples <br />of these integrity tests include, but are not limited to: visual inspection, hydrostatic testing, radiographic testing, <br />ultrasonic testing, acoustic emissions testing, or other systems of non-destructive testing. You must keep <br />comparison records and you must also inspect the container's supports and foundations. In addition, you must <br />frequently inspect the outside of the container for signs of deterioration, discharges, or accumulation of oil inside <br />diked areas. Records of inspections and tests kept under usual and customary business practices satisfy the <br />recordkeeping requirements of this paragraph. <br />112.7(e) Inspections, tests, and records. Conduct inspections and tests required by this part in accordance with <br />written procedures that you or the certifying engineer develop for the facility. You must keep these written <br />procedures and a record of the inspections and tests, signed by the appropriate supervisor or inspector, with the <br />SPCC Plan for a period of three years. Records of inspections and tests kept under usual and customary business <br />practices will suffice for purposes of this paragraph. <br />CORRECTIVE ACTION: Immediately ensure that all tanks are inspected and tested by an appropriately qualified <br />person in accordance with industry standards. Submit proof of correction and test results to the EHD. <br />This is a Class II violation. <br />FA0005630 PR0528795 SC001 08/17/2021 <br />EHD 28-01 Rev. 9/16/2020 Aboveground Petroleum Storage Act OIRPage 6 of 8 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.