Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CENTRAL VALLEY WASTE SERVICES 1 1333 E TURNER RD, LODI August 17, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 123 HSC 25110.10(d) Failure to annually submit notification of generator intent to remotely consolidate hazardous <br /> waste. <br /> OBSERVATION: The facility conducts remote consolidation operations consisting of spill clean-ups due to releases <br /> from garbage trucks. The remote consolidation notification is incomplete and missing the following: a general <br /> description of the remote location from which the non-RCRA hazardous waste will be initially collected, a description <br /> of the type of hazardous waste that may be collected, the location of the consolidation site and the generator ID <br /> number for that generator, significant differences in the generator's operations from the prior year's notification. <br /> REGULATION GUIDANCE: The annual submittal of a notification of the generator's intent to operate under this <br /> exemption is submitted to the California Environmental Reporting System (CERS). The notification required shall <br /> include all of the following information: a general description of the remote location from which the non-RCRA <br /> hazardous waste will be initially collected, a description of the type of hazardous waste that may be collected, the <br /> location of the consolidation site and the generator ID number for that generator, significant differences in the <br /> generator's operations from the prior year's notification. <br /> CORRECTIVE ACTION: Immediately submit the required information to CERS and return a corrective action <br /> statement to the San Joaquin County Environmental Health Department within 30 days. <br /> This is a minor violation. <br /> 303 CCR 66265.33 Failed to maintain all communication or alarm systems, spill control, or decontamination equipment. <br /> OBSERVATION: One fire extinguisher with indicator pointed to recharge was observed in the southwest corner of <br /> the MRF. <br /> REGULATION GUIDANCE:All facility communications or alarm systems,fire protection equipment, spill control <br /> equipment, and decontamination equipment,where required, shall be tested and maintained as necessary to assure <br /> its proper operation in time of emergency. <br /> CORRECTIVE ACTION: The violation was corrected during the inspection by replacing the fire extinguisher with a <br /> charged fire extinguisher. No further action is required to correct this violation. <br /> This is a repeat violation, Class II. <br /> FA0005630 PR0522742 SCO01 08/17/2021 <br /> EHD 22-02 Rev.9/16/2020 Page 6 of 9 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />