Laserfiche WebLink
c� E <br /> co o <br /> j v � <br /> p Q�pFESSIOHq <br /> 10 HN g <br /> as O OpGFyc <br /> "t Lo 00 Lo Lo Lo � <br /> N 0D C4 (o O J <br /> �O a E 23314 <br /> C c � ti D FCT R <br /> a) O F F 0 <br /> Q � rnrn O OF <br /> N N cc U <br /> -p U (O (fl <br /> Lo 0 + + <br /> L ZN <br /> w <br /> � w <br /> Z <br /> (7 <br /> � z� U I`04 <br /> O Wye �� <br /> Osp Z W N <br /> U W0° o04 <br /> �L <br /> .. O <br /> FIRE ALARM SYMBOLS o <br /> C,4 y <br /> o co� <br /> SYMBOL DESCRIPTION 1. FIRE ALARM SYSTEM EQUIPMENT&INSTALLATION SHALL BE IN ACCORDANCE WITH LATEST - = I- Y LL <br /> ADOPTED LIFE SAFETY CODE, NFPA 101,NFPA 72,NFPA 70(NEC),STATE AND LOCAL RULES AND - cu <br /> REGULATIONS,BUILDING CLASSIFICATION TYPE"M"MERCANTILE AND"B"BUSINESS. J U <br /> PULL STATION-INITIATION DEVICE,WITH TAMPERPROOF cu <br /> OUTPUT INPUT 0POLYCABONATE COVER AND 95-105dB LOCAL HORN.MOUNTED 2. FIRE ALARM SYSTEM SHALL BE INSTALLED BY AN N.F.P.A.,APPROVED FIRE ALARM INSTALLER AND uj CD <br /> CO <br /> BETWEEN 36"&44"AFF AS PER ADA.WP-INDICATES WEATHERPROOF LOCALLY APPROVED FIRE CONTRACTOR PER N.F.P.A.SECTION 7-6. FIRE ALARM SYSTEM SHALL � <br /> BE U.L.,N.F.P.A.,F.M.AND LOCALLY APPROVED.THE SYSTEM SHALL COMPLY WITH THE ABOVE a) <br /> HORN&STROBE-NOTIFICATION DEVICE,MOUNTED AT 80"AFF MIN.AND 96"AFF MENTIONED CODES,AMERICAN DISABILITY ACT(ADA)AND ALL OTHER APPLICABLE STATE AND >N <br /> CM V WP MAXIMUM ON WALLS/RACKS. MOUNTED FROM CEILING APPROX.28'AFF IN DRY LOCAL CODES&REGULATIONS. Q Lo <br /> 110cd SALES AND 24'IN COOLERS AND FREEZERS.WP-INDICATES WEATHERPROOF, <br /> CM-CEILING MOUNTED 110cd-REPRESENTS THE CANDELA LEVEL 3. THE FIRE ALARM CONTRACTOR SHALL COORDINATE WITH THE FIRE ALARM EQUIPMENT - <br /> MANUFACTURER FOR THE EXACT NUMBER AND SIZE OF ALL SYSTEM WIRING. ALL FIRE ALARM <br /> SYSTEM WIRING SHALL BE INSTALLED IN CONDUIT,SIZED IN ACCORDANCE WITH THE NATIONAL <br /> CM WP STROBE ONLY-NOTIFICATION DEVICE,MOUNTED AT 80"AFF MIN.AND 96"AFF p N <br /> MAXIMUM ON WALLS/RACKS. MOUNTED FROM CEILING APPROX.28'AFF IN DRY ELECTRICAL CODE. <br /> F MANUAL PULL STATIONS _\sT! ti O <br /> SALES AND 24'IN COOLERS AND FREEZERS.WP-INDICATES WEATHERPROOF, I` <br /> LOCATED AT ALL EXITS / \ CM-CEILING MOUNTED 110cd-REPRESENTS THE CANDELA LEVEL INTERCONNECTIONS AS CLEARLY AS POSSIBLE. IT DOES NOT SHOW ROUTING OR OFFSETS OF 4. THE FIRE ALARM RISER DIAGRAM AS SHOWN SERVES TO INDICATE THE ALARM DEVICE W <br /> 110cd <br /> TOP OF COOLER HVAC RTU'S(TYPICAL FOR ALL UNITS) INTERCONNECTIONS OR QUANTITIES. THE CONTRACTOR SHALL DETERMINE DEVICE LOCATIONS <br /> SID DUCT DETECTORS AT EXISTING UNITS WITH _\ / STROBE ONLY-NOTIFICATION DEVICE,MOUNTED AT 80"AFF MIN.AND 96"AFF FROM THE DRAWING AND SELECT OPTIMUM ROUTING OF INTERCONNECTIONS. COORDINATE <br /> OR FREEZERp sT- MAXIMUM ON WALLS/RACKS. WP-INDICATES WEATHERPROOF, WITH LIGHTING,SPRINKLER,HVAC AND PROVIDE OFFSETS AS MAY BE REQUIRED. <br /> REMOTE INDICATORS VISIBLE BELOW UNITS IN / \ <br /> INTERIOR OF SALES AREA 15cd CM-CEILING MOUNTED 15cd-REPRESENTS THE CANDELA LEVEL <br /> 5. ALL JUNCTION BOXES ASSOCIATED WITH THE FIRE ALARM SYSTEM SHALL BE PAINTED RED. <br /> RI <br /> REMOTE DUCT DETECTOR INDICATOR LED. A 6. ALL WIRING FOR FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE ALL LOCAL <br /> ZONE 1 �O/ TS 10"VIBRATING BELL OR INDEPENDENT CODES. <br /> AV /S \ AV 5 =S \ AV TONE ALARM CONDITION <br /> WP WP WP WP WP WP 10„ <br /> REMOTE DUCT DETECTOR TEST/RESET 7. SEE FLOOR PLANS FOR LOCATIONS OF ALL DEVICES.COORDINATE WITH SPRINKLER <br /> STATION WITH LED STATUS FOR EACH DUCT S CONTRACTOR FOR ALL FLOW,AND TAMPER SWITCH LOCATIONS. <br /> \ / \ / 8"VIBRATING BELL OR INDEPENDENT <br /> ZONE 2 E­- \(DtLj \ AV ,5 `j S \ AV DETECTOR LOCATIONS AND QUANTITIES TO ' TONE FOR SUPERVISORY CONDITION <br /> WP WP WP WP WP WP BE DETERMINED IN FIELD 8" <br /> 8. TAMPER AND FLOW SWITCHES SHALL BE SUPPLIED AND INSTALLED BY THE <br /> MECHANICAL/PLUMBING CONTRACTOR AND WIRED BY THE FIRE ALARM INSTALLER. <br /> _\ / \ /_\ / T 6"VIBRATING BELL OR INDEPENDENT TONE <br /> VAPOR PROOF ZONE 3 AV SO- AV �(S�- 5 AV C0 CARBON MONOXIDE DETECTOR NEAR RTU'S 9. DEVICE MOUNTING HEIGHT TO BE COORDINATED&APPROVED BY AUTHORITIES HAVING <br /> JUNCTION BOX / \ /Q\ /Q\ 6„ TROUBLE ALARM-TAMPER OR PANEL TROUBLE JURISDICTION. ALL STROBES HAVE BEEN RATED AT MINIMUM 110cd FOR MOUNTING AT CEILING. <br /> WP WP WP WPI WPI WP <br /> /n� n/� SMOKE DETECTOR LOCATED IN FRONT&MAIN 10. INSTALLATION CONTRACTOR SHALL COORDINATE WITH LOCAL INSPECTOR FOR DUAL AUTO <br /> ZONE 4 AV �SO\ AVY'jl--,\ AV Sc ELECTRICAL ROOM so SMOKE DETECTOR-INITIATION DEVICE DIALER TO A U.L.APPROVED CENTRAL STATION. <br /> IT IT PHOTOELECTRIC <br /> FIRE ALARM DEVICE Sp SMOKE DETECTOR LOCATED OVER FIRE 11. RISER DRAWING IS DIAGRAMMATIC.ALL CONDUITS SHALL NOT ENTER THE TOP OF THE FIRE <br /> ALARM PANEL.COORDINATE IN FIELD EXACT ROUTING AND INSTALLATION METHODS. <br /> ZONE 5 ALARM PANEL p <br /> so DUCT SMOKE DETECTOR-INITIATION DEVICE N <br /> AV AV AV AV \5 `5 / AV 12. FIRE ALARM INSTALLER SHALL GUARANTEE ALL WORK,MATERIAL,AND EQUIPMENT FOR A PERIOD Lo <br /> "'y 1-% /Q\ OF ONE(1)YEAR FROM DATE OF STORE OPENING. m <br /> 1. REFER TO ELECTRICAL DETAIL DRAWING PENETRATION DETAILS. II II o HEAT DETECTOR 13. ELECTRICAL CONTRACTOR TO PROVIDE AS BUILT DRAWINGS TO RESTAURANT DEPOT UPON U <br /> QUANTITY OF DEVICES SHALL <br /> BE DETERMINED IN THE FIELD. COMPLETION OF ALL WORK. <br /> (TYPICAL FOR ALL ZONES) Z d <br /> FIRE ALARM DEVICE INSTALLATION co CO/NO2 SENSOR PARKING GARAGE 14. FIRE ALARM INSTALLER SHALL FURNISH AND INSTALL COMPLETE FIRE ALARM SYSTEM O Z <br /> INCLUDING ALL PANELS,WIRING,ASSOCIATED BOXES,,CONDUITS,FITTINGS,CONNECTORS AND �ALL NECESSARY APPLIANCES FOR AN APPROVED FIRE ALARM INSTALLATION. <br /> &1NCOOLER/FREEZER) TS TS BACK FLOW PREVENTER. 0 <br /> 15. ALL CONDUCTORS SHALL BE MINIMUM#14 THWN-2 STRANDED COPPER 90 DEGREES C. <br /> oc FIRE DOOR RELAY CONTACT 16. FIRE ALARM INSTALLER SHALL COORDINATE ALL EFFORTS WITH FIRE OFFICIALS PRIOR TO 07 UTS AIR DRY SYSTEM AIR COMPRESSOR PURCHASE AND INSTALLATION OF ANY DEVICES. Z O <br /> MONITORING FS FLOW SWITCH 17. FIRE ALARM INSTALLER SHALL PROVIDE AND INSTALL AN ADDITIONAL MANUAL PULL STATION TO d <br /> (D co <br /> FIRE ALARM PANEL LOCATED IN BE LOCATED BY THE HEAD OF THE FIRE DEPARTMENT SERVICING THIS FACILITY. <br /> EXTERNAL POST INDICATOR VALVE H <br /> REAR ELECTRICAL ROOM PIV MONITOR OPEN OR CLOSE U m <br /> 18. THE FIRE ALARM INSTALLER SHALL INCLUDE IN BID;ALL WIRING AND INTERCONNECTIONS OF THE W W <br /> TS TAMPER SWITCH FIRE ALARM SYSTEM, FIRE ALARM INSTALLER SHALL INCLUDE COST FOR ALL TESTING OF ~ � <br /> TS TS TS FLOW AND TAMPER SWITCHES QUANTITY SYSTEMS,AND ALL OTHER PROVISIONS TO PROVIDE A COMPLETE AND WORKING SYSTEM AS = <br /> JUNCTION BOX FIRE ALARM SYSTEM RESET OF DEVICES SHALL BE VERIFIED IN THE DESIGNATED BY THE LOCAL AUTHORITY. � Q <br /> INSTRUCTIONS SHALL BE TYPED FIELD. POST INDICATOR VALVE-MONITOR FOR OPEN AND CLOSE Q (n <br /> AND MOUNTED ON WALL NEXT TO FS FS FS ED19. ELECTRICAL CONTRACTOR SHALL PROVIDE A COST PER UNIT LINE ITEM PRICE PLUS COST OF U) <br /> FIRE ALARM PANEL INSTALLATION FOR ADDITIONAL FIRE ALARM DEVICES AS MAY BE DIRECTED BY THE INSPECTOR. Q W <br /> UPON FINAL INSPECTION THESE ADDITIONAL REQUIREMENTS SHALL INCLUDE ALL CIRCUITING, Q <br /> ED DRY SYSTEM MONITORING-MONITORS AIR PRESSURE IN DRY SYSTEM SYSTEM. <br /> MOUNTING HARDWARE,LABOR,TESTING,ETC.TO INSTALL THE DEVICES,AND COMPLETE THE Z <br /> SYSTEM. O <br /> Z AUTO 20. IT IS THE INTENT OF THIS FIRE ALARM SYSTEM TO FULLY COMPLY WITH ALL STATE AND LOCAL W <br /> } <br /> (2)DEDICATED TELEPHONES AUTHORITIES IT IS THE RESPONSIBILITY OF THE INSTALLATION CONTRACTOR TO COORDINATE ALL <br /> CEILING NUMBERS AND LINES = DIALER RI REMOTE INDICATOR AT ALL HVAC DUCT DETECTORS COMMUNICATION BETWEEN RESTAURANT DEPOT'S FIRE ALARM SYSTEM AND LOCAL UL LISTED Q m <br /> MONITORING SERVICE. W = <br /> REMOTE <br /> O <br /> UL APPROVED CENTRAL ANNUNCIATOR 21. FIRE ALARM INSTALLER SHALL SUBMIT ALL BATTERY CALCULATIONS,EQUIPMENT <br /> TS <br /> STATION AUTO DIALER MANUAL TEST/RESET SWITCH SPECIFICATIONS,NUMBER OF DEVICES,AND ROUTING OF CABLES DURING APPLICATION FOR W <br /> PULL STATION OR DIGITAL CELL LINE. ANNUNCIATOR PANEL PERMIT SUBMISSION. FIRE ALARM INSTALLER SHALL BE STATE APPROVED AND SHALL ATTEND of >- <br /> WITH COVER LOCATED IN THE FRONT ALL INSPECTIONS. W <br /> ENTRY pg DRY SPRINKLER PRESSURE SWITCH 22. FIRE ALARM INSTALLER SHALL SUBMIT(3)SETS OF PLANS WITH EQUIPMENT CUTS TO LOCAL FIRE Z 07 <br /> DEPARTMENT(CALL THE BUILDING DEPARTMENT BEFORE SUBMISSION). <br /> VAPOR PROOF 23. WIRE SIZES SHALL BE AS FOLLOWS: Q X <br /> JUNCTION BOX CO CARBON MONOXIDE DETECTOR 24. A.C.POWER------------------------------#10 W <br /> 25. ANNUNCIATION AND CONTROL---------#14 AWG MIN.,F.A.CABLE 0 (/) <br /> 26. INITIATION-------------#16 TWISTED SHIELDED MIN.,F.A.CABLE IL <br /> MM MM MONITOR MODULE 27. ALL POWER WIRING SHALL BE INSTALLED IN R.G.S.(3/4"MINIMUM),ALL F.A.CABLE SHALL BE Z <br /> INSTALLED IN EMT WITH COMPRESSION FITTINGS. Z W <br /> 28. CONDUCTORS FOR DETECTORS,MANUAL RELEASE STATION AND SUPERVISORY DEVICE CAN BE � <br /> ®FPR POINT OF CONNECTION FOR A TROUBLE FROM FIRE PUMP"OFF"OR"MANUAL" INSTALLED IN THE SAME RACEWAY BUT MUST BE INSTALLED IN A SEPARATE RACEWAY FROM ALL Z U <br /> PULL S TAT I O N DEVICE INSTALLATION INDICATING DEVICES(BELL AND HORN/STROBE)AND FROM 120 VAC CIRCUITS 0 O <br /> 0 <br /> 29. DETECTOR LOCATIONS MAY VARY A FEW FEET TO AVOID ANY LIGHT FIXTURES OR U) <br /> �N'TOOLER/FREEZER) ®FPOM POINT OF CONNECTION FOR A TROUBLE FROM FIRE PUMP RUNNING OBSTRUCTIONS.DO NOT INSTALL A DETECTOR WITHIN T OF A SUPPLY REGISTER. zLLI U) <br /> 30. ALL CONDUCTORS ARE TO BE PROPERLY TAGGED OR NUMBERED IN THE CONTROL PANEL AND <br /> Lu <br /> Q) <br /> (:D2 S FIRE ALARM RISER S E R AN D SCHEDULES ® CORRESPOND WITH CONTROL PANEL TERMINAL OR FIELD WIRE NUMBERS FOR IDENTIFICATION <br /> 3 FPCT POINT OF CONNECTION FOR A TROUBLE FROM FIRE PUMP COMMON TROUBLE PURPOSES. 0 LL <br /> NTS %IZIiIiiIi00 <br /> 31. WIRING CIRCUITS MUST GO TO AND FROM EACH DEVICE.BRANCH CIRCUITS ARE NOT PERMITTED. 0 LLI <br /> NOTE:ALL SYMBOLS ARE NOT USED. POLARITY MUST BE OBSERVED THROUGHOUT. W <br /> N <br /> THE FIRE ALARM PLAN LAYOUT AND SINGLE LINE ARE PROVIDED TO ILLUSTRATE 32. POWER TO CONTROL PANEL AND CONNECTION OF BATTERIES TO CONTROL PANEL TO BE MADE 'Ova W 0 <br /> UNDER SUPERVISION OF FIELD TECHNICAL REPRESENTATIVE. = W <br /> THE SCOPE OF WORK, GENERAL LOGIC OF THE SYSTEM AND FOR PRICING H- N <br /> PURPOSES. THE AWARDED CONTRACTOR SHALL PROVIDE A FIRE ALARM LAYOUT 33. ALL DEVICES ARE TO BE FLUSH MOUNTED WHEREVER POSSIBLE. z E <br /> INCLUDING ALL DEVICES WITH PROPER SPACING, BATTERY CALCULATIONS,AND O <br /> B.O.M.; INCLUDING ALL DEVICES,ACCESSORIES, MODULES AND ALL 34. INSTALLER MUST PLACE DUST COVERS ON ALL DETECTORS.DUST COVERS SHALL BE REMOVED J <br /> INTERCONNECTING COMPONENTS. THE CONTRACTOR SHALL BE A UL APPROVED ONLY BY UNITED FIRE TECHNICAL PERSONNEL AT THE TIME OF THE FINAL CHECK-OUT. uj <br /> FIRE ALARM CONTRACTOR. 35. ALL DETECTOR CIRCUITS TO BE CHECKED FOR OPENS,GROUND FAULTS AND SHORTS BEFORE LLI <br /> FIRE ALARM SEQUENCE OF OPERATIONS CONNECTING TO CONTROL PANEL. <br /> 36. NO CONDUIT OR WIRE MAY ENTER TOP OF CONTROL PANEL. Q <br /> NOTES: 37. ALL CONNECTIONS AND INSTALLATION OF ELECTRICAL DEVICES FOR ENTIRE SYSTEM TO BE BY <br /> THIS CONTRACTOR. Lo <br /> 1. FIRE DEPARTMENT AND CENTRAL MONITORING COMPANY TO p <br /> RECEIVE SEPARATE AND DISTINCT SIGNALS. 38. TOP OF CONTROL PANEL TO BE MOUNTED NOT MORE THAN 6 FEET ABOVE FLOOR. <br /> 2 <br /> a)MANUAL PULL ALARM 39. MANUAL RELEASE STATIONS TO BE MOUNTED 4'-0"ABOVE RAISED FLOOR. <br /> z O O U) b)SPRINKLER FLOW ALARM 40. FIRE ALARM SYSTEM SHALL BE A FULLY ADDRESSABLE INTERIOR FIRE ALARM(I.F.A.)IN <br /> O w w F d c)AUTOMATIC ALARM(i.e.,SMOKE&DUCT DETECTORS.) ACCORDANCE WITH THE BUILDING CODE OF THE LOCAL JURISDICTION. <br /> Q <br /> U) ai o p ? w a d)TROUBLE&SUPERVISORY SIGNAL 41. EXTREME CARE MUST BE TAKEN TO AVOID GROUND FAULT CONDITIONS OF ALL CONDUCTORS. <br /> J <br /> aO O w a < e)FIRE PUMP SUPERVISORY SIGNAL 42. CONTRACTOR TO SUBMIT PLANS TO AND OBTAIN PERMIT FROM FIRE PREVENTION DIVISION FOR <br /> U- > � of f EVACUATION TONE SHALL BE 3 PULSE TEMPORAL PATTERN. THE INSTALLATION OR MODIFICATION OF FIRE ALARM SYSTEM. <br /> w Q U) U) Of 0-1Q > ) <br /> D <br /> w U F 0- p O 2.ALL FANS TO BE MANUALLY RESTARTED.AUTOMATIC 43. THE GENERAL CONTRACTOR SHALL COORDINATE THE FIRE ALARM SYSTEM INTERFACE BETWEEN <br /> 00 < Q 0 < D 0 p RESTART IS NOT PERMITTED THE FIRE ALARM CONTRACTOR,SPRINKLER CONTRACTOR,MECHANICAL CONTRACTOR,AND ANY <br /> U- U- U- U- U- U- p H OTHER PERTINENT TRADES. <br /> O O O O O O z w 3.ALL SIGNALS TO FIRE ALARM PANEL TO BE DUPLICATED <br /> z z z z z z Ow <br /> v AT REMOTE ANNUNCIATOR PANEL LOCATED BY ENTRANCE <br /> O O O O O O J o AND SHALL ALSO RING APPROPRIATE VIBRATING BELLS. <br /> > > > Y w 4. ALL TROUBLE AND SUPERVISORY ALARMS SHALL INITIATE REVISIONS <br /> Q Q Q Q Q Q w 2 >_ TROUBLE SEQUENCE IN ADJACENT TENANT,FLOW ALARM <br /> SHALL INITIATE HORN STROBE IN ADJACENT TENANT. <br /> X X X X X X X X AND ACTIVATES <br /> REMOTE OAN UNC A 0NE 1 ANNUNCIATION ON FACP <br /> X XX X X ACTIVATES HORNS TO SOUND SPECIFIC CODE <br /> X X X X ACTIVATES EXTERIOR BELL <br /> X v v v ACTIVATES HORN/STROBE LIGHTS THROUGHOUT <br /> /� �/ �/ /� /� (NOTE:SHUT OFF AFTER APPROVED AMOUNT OF ROUNDS) <br /> X X X X X X TRANSMITS SIGNAL TO CENTRAL MONITORING COMPANY <br /> �/ <br /> ACTIVATES RELAY TO SHUT OFF ALL AC UNITS IN EXCESS <br /> X X OF 2000CFM(MANUAL RESET) o <br /> X X X INITIATES TROUBLE SIGNAL AT FACP AND ANNUNCIATOR <br /> * * O <br /> LL <br /> X X X X SENDS SIGNAL TO SHUT DOWN CEILING FAN CF-1 AND CF-2 11J o <br /> X TEMPRAL 4 SOUND AT UNIT C/) <br /> 0 <br /> * SEQUENCE OF OPERATION MUST COMPLY WITH LOCAL FIRE DEPARTMENT REQUIREMENTS. Q <br /> o <br /> ** E.C.SHALL COORDINATE WITH LOCAL UTILITY AND OWNER WHETHER DUCT DETECTORS AND EGRESS PULL <br /> STATIONS ARE TO BE TIED TO CENTRAL STATION OR JUST FOR LOCAL NOTIFICATION. THIS WILL PREVENT <br /> NUISANCE CALLS TO CENTRAL STATION BUT MUST BE APPROVED BY FIRE MARSHAL. 4 N CO � LO CO ti 00 rn o <br /> FIRE ALARM <br /> SYSTEM NOTES <br /> AND RISER <br /> FOR PERMIT DATE: 11/06/2020 <br /> JOB NO. 20263 <br /> FAm2 <br /> ■ <br /> 0 <br /> SHEET NO. <br />