Laserfiche WebLink
CD E <br /> co o <br /> EXISTING ROOFTOP UNIT SCHEDULE <br /> FAN SECTION HEATING SECTION DIFFUSER REGISTER AND GRILLE SCHEDULE D �' OQ�o Mss/ Nq�� <br /> S <br /> Ro <br /> UNIT ID MFR. MODEL CONN. SIZE DESCRIPTION NOTESO Wh�Q\� F'L�y�'y <br /> UNIT COIL AREA SERVED STATUS MANUFACTURER UNIT MODEL SUPPLY OUTDOOR HEAT NOTESLo Ln co 0 m M 38871 <br /> NOMINALTONS NUMBER AIRFLOW AIRFLOW SOURCE SD-1 AES DROP BOX 24x24 18 GAUGE GALVANIZED STEEL CONSTRUCTION, TDC FLANGE FOR DUCT CONNECTION, DOUBLE 1 THRU 5 U p rn rn c: <br /> (TON) (CFM) (CFM) INDUSTRIES ADB-1-12-4 DEFLECTION DRUM LOUVERS, 4-WAY BLOW PATTERN CONFIGURATION. COORDINATE WITH c: ---) r (D JJ P <br /> CHA <br /> AC-1 10 GENERAL SALES REMAIN, CAPPED TRANE YHC120A3RMA003X - - NATURAL GAS - 12.5 TON UNIT HVAC ROOF TOP UNIT SCHEDULE & LATEST FLOOR PLAN DESIGN. PROVIDE DUCT TRANSITION KIT Z Lo Lo > 9TF�F CAV��`ci <br /> AC-2 10 GENERAL SALES REMAIN, CAPPED TRANE YHC120A3RMA003X - - NATURAL GAS - & ANY OTHER REQUIRED MATERIALS (GASKETS, BAFFELS, DUCTWORK/ETC...) FOR PROPER 0O - - O <br /> INSTALLATION. REFER TO ASSEMBLY MANUAL FOR INSTALLATION PROCEDURES. Q- }' 0 0 O <br /> AC-3 10 GENERAL SALES REMAIN,REBALANCED TRANE YHC120A3RMA003X 3,400 2,800 - 1 THRU 4 0 v <br /> ........................ v CO cfl <br /> AC-4 10 GENERAL SALES REMAIN,REBALANCED TRANE YHC120A3RMA003X 3,400 2,800 NATURAL GAS 1 THRU 4Lo <br /> T <br /> AC-5 12.5 GENERAL SALES REMAIN,REBALANCED TRANE YCD151C3HABB 4,000 3,400 NATURAL GAS 1 THRU 4 SD-2 AES DROP BOX 20x20 18 GAUGE GALVANIZED STEEL CONSTRUCTION, TDC FLANGE FOR DUCT CONNECTION, DOUBLE 1 THRU 5 + + <br /> AC-6 12.5 GENERAL SALES REMAIN,REBALANCED TRANE YCD151C3HOBA 4,000 3,400 NATURAL GAS 1 THRU 4 INDUSTRIES ADB-1-10-4 DEFLECTION DRUM LOUVERS, 4-WAY BLOW PATTERN CONFIGURATION. COORDINATE WITH L <br /> 10 TON UNIT HVAC ROOF TOP UNIT SCHEDULE & LATEST FLOOR PLAN DESIGN. PROVIDE DUCT TRANSITION KIT Z <br /> AC-7 5 GENERAL SALES REMAIN,REBALANCED TRANE YHC063A4RLAOVKF 2,000 1,600 NATURAL GAS 1 THRU 4 � '. U1 <br /> & ANY OTHER REQUIRED MATERIALS (GASKETS, BAFFELS, DUCTWORK/ETC...) FOR PROPER Ln E <br /> AC-88 12.5 GENERAL SALES REMAIN,REBALANCED TRANE YCD151C3HABB 4,200 2,800 NATURAL GAS 1,2,4 ; _ <br /> AIw Iw 0 ti� <br /> INSTALLATION. REFER TO ASSEMBLY MANUAL FOR INSTALLATION PROCEDURES. O y <br /> AC-9 10 OFFICES REMAIN,REBALANCED TRANE YHC120A3RMA003X 3,400 2,800 NATURAL GAS 1,2,4 *0 W j <br /> U WOcn <br /> ° o� <br /> SD-3 AES DROP BOX 14x14 18 GAUGE GALVANIZED STEEL CONSTRUCTION, TDC FLANGE FOR DUCT CONNECTION, DOUBLE 1 THRU 5 <br /> o <br /> NOTES: INDUSTRIES ADB-1-5-4 DEFLECTION DRUM LOUVERS, 4-WAY BLOW PATTERN CONFIGURATION. COORDINATE WITH - rn <br /> 1. FOR RTU REQUIRED SCOPE OF WORK SEE KEY NOTES ON MECHANICAL FLOOR PLAN. 5 TON UNIT HVAC ROOF TOP UNIT SCHEDULE & LATEST FLOOR PLAN DESIGN. PROVIDE DUCT TRANSITION KIT 70o N <br /> 2. PROVIDE MERV-13 FILTERS AND SPARE SET OF MERV-13 FILTERS FOR ALL RTUS. & ANY OTHER REQUIRED MATERIALS (GASKETS, BAFFELS, DUCTWORK/ETC...) FOR PROPER 3: <br /> 3. PROVIDE SUPPLY DROP BOX. REFER TO SCHEDULE. INSTALLATION. REFER TO ASSEMBLY MANUAL FOR INSTALLATION PROCEDURES. _ r , J c- <br /> 4. <br /> 4. LANDLORD RESPONSIBLE FOR PROPERLY OPERATING EXISTING SMOKE DETECTORS (MAIN SUPPLY DUCT MOUNTED. COORDINATE W/ GOVERNING CODES & CODE OFFICIAL). - U L <br /> LANDLORD SHALL REPLACE EXISTING SMOKE DETECTORS WITH NEW IF REQUIRED. cq <br /> W <br /> ALUMINUM, DOUBLE DEFLECTION SUPPLY GRILLE WITH, 3/4" BLADE SPACING, 1,2,4 <br /> SR TITUS S300FL SEE PLANS FRONT BARS PARALLEL TO THE SHORT DIMENSION WITH RADIUS END CAPS TO MATCH DUCT aD <br /> I T O D <br /> Q Lo 3: <br /> o� <br /> a� <br /> FAN SCHEDULE = U �� <br /> 12"x12" FACE 9"x9" MODULE LOUVER FACED SQUARE CEILING DIFFUSER NECK o c <br /> UNIT ID dANUFACTUREI MODEL SERVICE TYPE DRIVE CFM RPM SP MOTOR INTERLOCK UNIT WEIGHT ACCESSORIES CD TITUS TDCA SEE PLAN SIZE AS SHOWN ON PLANS. 1,2,4 ti 0 <br /> IN. WG. HP VOLTS PHASE LBS <br /> GEF-1 GREENHECK GB-091-4 BATTERY CHARGING ROOF BELT 720 1,354 0.5 1/4 115 1 RUNS CONTINUOUSLY 58 1 THRU 9 22 <br /> SVF-1,2 FANTECH FR150-5C517 FREEZER SLAB VENTING INLINE DIRECT 230 2,750 0.2 1/10 115 1 RUNS CONTINUOUSLY 10 NOTES <br /> 1. MAXIMUM NOISE CRITERION RATING < 30 <br /> 2. BAKED ENAMEL FINISH, COLOR TO BE SELECTED BY ARCHITECT. <br /> NOTES: 4. COORDINATE DROP BOX LOCATION WITH CORRESPOND EXISTING RTU LOCATION. <br /> 1. RD TO PROVIDE UNIT AND ALL ACCESSORIES. CONTRACTOR RESPONSIBLE TO RECEIVE AND STORE EQUIPMENT, AND COORDINATE INSTALLATION OF ALL COMPONENTS. 5. DROP BOX NECK SIZE SHALL BE IN ACCORDANCE WITH TABLE. <br /> 2. BURGLAR BARS AT ROOF PENETRATION. <br /> 3. 14" HIGH PRE-FAB ROOF CURB (SEISMIC RATED IF REQUIRED). <br /> 4. DISCONNECT SWITCH (WEATHERPROOF AS REQUIRED). <br /> 5. BACKDRAFT DAMPER. <br /> 6. ALUMINUM BIRD SCREEN. <br /> 7. PROVIDE FLEXIBLE CONNECTORS AT DUCT CONNECTION. <br /> 8. PROVIDE ADAPTER PLATE AT FAN CONNECTION. <br /> 9. HARDWIRE TO CIRCUIT BREAKER. <br /> 10. SVF FANS PROVIDE AND INSTALL BY HVAC CONTRACTOR. p <br /> N <br /> Lo <br /> m <br /> Ile <br /> U <br /> Z O <br /> O z <br /> Y � <br /> U <br /> O z <br /> U) U Z <br /> z O <br /> - 0- <br /> 17)2 <br /> U <br /> W W <br /> W <br /> U CD <br /> C)f Q <br /> Q U) <br /> Q u) <br /> W <br /> Q J <br /> Z <br /> O <br /> } W <br /> Q co <br /> w O <br /> lY � <br /> � W <br /> lY � <br /> � J <br /> u) <br /> Z LU <br /> _O � <br /> ELECTRIC HEATER SCHEDULE w <br /> UNIT ID MANUFACTURER MODEL AREA SERVED CFM HEATING DATA ELECTRICAL INTERLOCKED NOTES O Z? <br /> INPUT KW OUTPUT (MBH) FLA VOLTS PHASE HERTZ WITH z cn <br /> EUH-1, 2 QMARK 25D233 FUTURE EXPANSION AREA 350 3.0 - - 208 1 60 THERMOSTAT 1 thru 5 z z <br /> Lu <br /> EUH-3, 4 QMARK 25D236 RECEIVING AREA 350 5.0 - - 208 1 60 THERMOSTAT 1 thru 5 <br /> O U <br /> NOTES: C� O <br /> U 0 <br /> 1. ABOVE LISTED EQUIPMENT PROVIDE AND INSTALL BY HVAC CONTRACTOR. = W <br /> 2. PROVIDE DISCONNECT SWITCH. Lu _ <br /> 3. PROVIDE TSTAT. (BUILT-IN T'STAT FOR EB) <br /> 4. PROVIDE MOUNTING HARDWARE. <br /> 0 U- <br /> 5. FIELD VERIFY FINAL MOUNTING HEIGHTS. COORDINATE W/ARCHITECT, RESTAURANT DEPOT REPRESENTATIVE, & MFR'S RECOMMENDATIONS. o Lu <br /> W v) <br /> W =) <br /> W o <br /> = W <br /> N <br /> W Orf <br /> ELECTRIC AIR CURTAIN SCHEDULE Q <br /> UNIT ID MANUFACTURER MODEL LENGTH AREA SERVED FAN DATA HEATING DATA ELECTRICAL INTERLOCKED WEIGHT NOTES elf <br /> CFM HP KW INPUTAMP MOCP VOLTS PHASE HERTZ WITH LB W Q <br /> ACR-1 POWERED AIRE ETA-2-72E 6-0" ENTRY DOORS 2620 (2)3/4 20 27.8 35 208 3 60 THERMOSTAT 177 1 THRU 8 <br /> 2 <br /> NOTES: <br /> 1. RESTAURANT DEPOT TO PROVIDE "ACR" AND ALL ACCESSORIES. ALL OTHER UNITS BY CONTRACTOR. CONTRACTOR RESPONSIBLE <br /> TO RECEIVE AND STORE EQUIPMENT, AND COORDINATE INSTALLATION OF ALL COMPONENTS. <br /> 2. FIELD VERIFY FINAL MOUNTING HEIGHTS. COORDINATE W/ARCHITECT, RESTAURANT DEPOT REPRESENTATIVE, & MFR'S RECOMMENDATIONS. <br /> 3. TRANSFORMER AND CONTACT SWITCH FOR OPERATION WITH BI-PARTING OR OVERHEAD DOOR BY MANUFACTURER. <br /> 4. UNIT MOUNT HIGH/LOW SWITCH BY MANUFACTURER. <br /> 5. REMOTE MOUNTED HIGH/OFF/LOW SELECTOR SWITCHES BY MANUFACTURER <br /> 6. UNIT MOUNTED DISCONNECTS BY MANUFACTURER. <br /> 7. MAGNETIC DOOR SWITCHES BY MANUFACTURER. <br /> 8. 1/2" RE-CLEANABLE FILTERS BY MANUFACTURER. <br /> REVISIONS <br /> o <br /> ui <br /> z <br /> o 2E� <br /> o <br /> u.l u U <br /> d } <br /> U <br /> H U) U <br /> 0 0 <br /> W N N <br /> Q o <br /> 0 ` N <br /> zm N M V Lo CO ti 00 m <br /> MECHANICAL <br /> SCHEDULES <br /> FOR PERMIT DATE: 11/06/2020 <br /> JOB NO. 20263 <br /> M -3 . 0 <br /> Li SHEET NO. <br />