S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GOLD RIVER ORCHARDS, INC 1 18400 ENTERPRISE RD, ESCALON September 27, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> OBSERVATION: <br /> -spill control equipments are missing in pump station shed <br /> -eye wash station next to door 12 and profum cage is inoperable <br /> -secondary containment pallet for the used anti-freeze drum and used metal oil filter was observed with some areas <br /> of the secondary containment with standing liquid. <br /> REGULATION GUIDANCE:All facility communications or alarm systems,fire protection equipment, spill control <br /> equipment, and decontamination equipment,where required, shall be tested and maintained as necessary to assure <br /> its proper operation in time of emergency. <br /> CORRECTIVE ACTION: Bring the all above list into proper working order by repair, replacement or testing. <br /> Provide a corrective action statement to the San Joaquin County Environmental Health Department within 30 days. <br /> This is a Class II violation. <br /> 304 CCR 66262.34(d)(2) Failed to maintain adequate aisle space for unobstructed response to emergencies. <br /> OBSERVATION: The following area does not have adequate aisle space: <br /> -the hazardous waste storage area has an inadequate aisle space between the cage of empty propane tanks and <br /> secondary containment of the gasoline and diesel <br /> REGULATION GUIDANCE: The owner or operator shall maintain aisle space to allow the unobstructed movement <br /> of personnel,fire protection equipment, spill control equipment, and decontamination equipment to any area of <br /> facility operation in an emergency, unless it can be demonstrated to the Department that aisle space is not needed <br /> for any of these purposes. <br /> CORRECTIVE ACTION: Immediately maintain aisle space to allow the unobstructed movement of personnel,fire <br /> protection, spill control equipment, and decontamination equipment to any area of facility operation in an <br /> emergency. Provide a corrective action statement to the San Joaquin County Environmental Health Department <br /> within 30 days. <br /> This is a Class II violation. <br /> FA0026783 PR0547197 SCO01 09/27/2021 <br /> EHD 22-01 Rev.9/16/2020 Page 8 of 12 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />