Laserfiche WebLink
PLUMBING FIXTURE SCHEDULE <br /> FOOD SERVICE NOTES PLUMBING LEGEND lNTERPLAN§ <br /> TAG CITY. FIXTURE MANUFACTURER MODEL.# fAUCETiVAL1LE <br /> TAG MANUFACTURER MODEL NUMBER FIXTURE DESCRIPTION CONNECTION SCHEDULE 1. ALL SERVICE LINES FOR WATER SIZED TO PROVIDE FULL FLOW VOLUME FOR ALL ITEMS �- DIRECTION OF FLOW IN PIPE <br /> SUPPLIED ON RESPECTIVE MAINS AND BRANCHES. IDENTIFY ALL LINES WITH PERMANENT ARCHITECTURE <br /> WASTE 1/ENT CW HW LABELS FOR THE SERVICE" THEY PROVIDE. � PITCH PIPE DOWN IN DIRECTION OF ARROW ENGINEERING <br /> FURIViSH AICA CLOSET� TANK,ADA 16-�.r2" HIGH. �2" RauGl-1- Iry FURNISH WITH INTERIOR DESIGN <br /> WC-1 1 HANDICAP WATER POLISHED.CHROME FLUSH ACTUATOR. COLOR` 815QUE OPEN FRONT SEAT, -`-O--fl PIPE UP <br /> CLOSET <br /> AMERICAN. 27OAA 1.0 020 _ 2. ALL HOT AND COLD WATER SERVICE LINES, EXCEPT SHORT BRANCHES EXTENDED AND PROJECT MANAGEMENT <br /> INTEGRAL BUMPERS,.EXTERNAL CHECK HINGES WITH STAINLESS STEEL POSTS. 3" 2,, CONNECTED TO FIXTURES, SHALL BE INSULATED. ALL EXPOSED INSULATED LINES SHALL BE <br /> COLOR: WHITE. 1.25GPF TANK WATER CLOSET. PRESSURE ASSISTED SIPHON 9l2„ - � PIPE DOWN <br /> COVERED WITH PROTECTIVE COVERING .TO SUIT THE APPLICATION. <br /> JET.. WHITE VITREUMS CHINA ELONGATED BOWL. <br /> 3. ALL HORIZONTAL PIPING LINES EXTENDED AND CONNECTED TO EQUIPMENT, BELOW -� EXPANSION JOINT <br /> LAV-1 1 HANDICAP WALL CONCEALED ARM HANGER: FAUCET-HOLES AT 4" CENTERS. PROVIDE WITH EQUIPMENT, SHALL BE RUN AT THE HIGHEST POSSIBLE ELEVATION ABOVE FLOG <br /> HUNG LAVATORY EAMERICANSTANDARD .0355,012 CHICAGO PROVIDE CLEARANCE FOR CLEARING. NO LINES R, TO �+- FLEXIBLE PIPE CONNECTOR <br /> 802 CONCEALED ARM CARRIER MOUNT TOP OF RIM AT 34"AFF._CHICAGO FAUCET 2" SHALL LAY ON FLOOR. 604 COURTLAND STREET <br /> #802, 4" SPOUT, METAL LEVER HANDLES, AND QUATURN.CART. 1 1I4 1/2 112. --SOF--- BALL VALVE SUITE 100 <br /> 4. ALL PIPING ROUTED THROUGH OR NEAR EQUIPMENT OR COUNTERS SHALL NOT INTERFERE ORLANDO, FLORIDA 32804 <br /> �'_1 3 TRAP PRIMER zURN _ _ WITH THE INTENDED USE OF, OR SERVICING OF, EQUIPMENT OR COUNTERS. -' <br /> 21021 --�--- CHECK VALVE, HORIZONTAL SWING PH 407.645,5008 <br /> WATER SAVER TRAP PRIMER. SEE DETAIL ON P301 - - _ - 5. ALL EXPOSED PIPING AND FITTINGS SHALL BE CHROME PLATED OR STAINLESSFX 407,629,9124 <br /> STEEL. TAIL --�----- GATE VALVE <br /> 1 3 PIECES FOR SINKS SHALL BE 17 GAUGE CHROME PLATED FLARED BRASS TUBING FOR <br /> FLOOR DRAIN ZURN. Z 415 CONNECTION TO 1-1/2" I.P.S. MALE THREAD FITTING. "P" TRAPS SHALL B �-- BUTTERFLY SEAL: <br /> TYPE "N" STRAINER. PROVIDE WITH COMPLETE BODY ASSEMBLY WITH TRAP E CHROME PLATED VALVE <br /> BRASS, UNIFORM CODE PATTERN. THIS DOCUMENT IS"NOT FOR CONSTRUCTION" <br /> PRIMER CONNEC170N ---D�- GLOBE VALVE UNLESS THE ARCHITECT OR ENGINEER'S <br /> SIGNATURE AND SEAL APPEAR BELOW, <br /> S-1 6. STOPS SHALL BE FURNISHED AND INSTALLED ON ALL HOT AND COLD WATER LINES AT BACKWATER VALVE <br /> 4 FLOOR SINK J.R. SMITH 3000 SERIES TYPE "K" FLOOR SINK IN KITCHEN AND FOOD SERVICE AREAS SHALL BE J.R, EQUIPMENT. PROVIDE ALL REQUIRED SHUT-OFF VALVES, CHROME FINISH. <br /> SMITH 3000 SERIES WITH SEDIM ENT BUCKET AND 12 1/2 NICKEL BRONZE _ ---� BALANCING VALVE <br /> SQUARE TOP 10" DEEP 1I2 GRATE. SEE PLAN FOR LOCATIONS.. - 7. KITCHEN EQUIPMENT DIVISION SHALL PROVIDE ALL FOOD SERVICE EQUIPMENT FAUCETS. ---�-- CHECK VALVE <br /> PLUMBING CONTRACTOR SHALL INSTALL AND CONNECT. EQUIPMENT SINKS ARE PROVIDED <br /> FOO-1 - FLOOR CLEANOUT - WITH 1-1/2" WASTE CONNECTIONS. -- - DIAPHRAGM VALVE /,� J�,1, <br /> ZIJRIV E E <br /> 1454 .E - �{3UQ��t <br /> SIZE PER PIPING LATERAL, 4't MAX - - 8. ALL WASTES, DIRECT OR INDIRECT, SHALL BE F GAS COCK VALVE F� <br /> FURNISHED AND INSTALLED BY THE PLUMBING <br /> CONTRACTOR EXCEPT AS NOTED ON UTILITY PLANS. ---0au---- HOSE END DRAIN VALVE ���,�� <br /> �c sn <br /> O-�F 4 WALL CLEANOUT MOUNTTOPWALL-HUNG VITREOUS CHINA WATER CLOSET ELONGATED BOWL 9. MINIMUM SIZE INDIRECT WASTES SHALL BE 1", REGARDLESS OF SIZE OF CONNECTION A - VALVE IN VERTICAL > •tZ .b �f <br /> ZURN Z 1446 ClVV _ MOUNTTUP OF RIM AT 14"A.F-F. FLUSH VALVE -SLOAN NO. 111 T <br /> SEAT-OLSONITE IVU. 05CT 3" _ - - EQUIPMENT. --��I UNION <br /> LOW WATER CONSUMPTION.(1.3 GPF 10. ADEQUATE CLEAN-OUT PROVISION SHALL BE MADE FOR ALL WASTE LINES BY MEANS OF Affil PRESSURE REDUCING VALVE ¢ <br /> TMV-1 3TO ACCESSIBLE POSITION. ---r�s,I SWING CHECK <br /> MIXING VALINE WATTS LFUSG-B-M2 PLUGGED "T" FITTING EXTENDED VALVE <br /> - UNDER RESTROaM`LAVS AND HAND SINKS. _ <br /> 11. WATER SERVICES FOR PORTABLE AND COUNTER TOP APPLIANCES SHALL BE CONNECTED TOSPRING CHECK VALVE <br /> - - - EQUIPMENT WITH STAINLESS STEEL FLEXIBLE HOSES AND QUICK DISCONNECT FITTINGS. SPECIAL GATE VALVE <br /> WATER HOSES SHALL BE COVERED WITH A THICK FIRE RESISTANT PLASTIC OR POLY <br /> 40 1 WATER HEATER AO SMITH COATING. --0o--- SPECIAL GATE VALVE <br /> CYCLONE BTH-1.50 _ `` Larson <br /> 100 GAL, '15©,000 BTU GAS FIRED WATER.'HEATER: 98% THERMAL EFFICIENCY. � <br /> -------------- <br /> 1" 1" 12. PLUMBING CONTRACTOR SHALL COORDINATE WITH KITCHEN CONSULTANT DRAWINGS FOR C HOSE END VALVE Engineering, Inc. <br /> ___ ROUGH IN LOCATIONS, SIZES AND HOOK-UP REQUIREMENTS FOR ALL KITCHEN EQUIPMENT. <br /> 41.1 1 ROUGH IN EQUIPMENT PER MANUFACTURERS RECOMMENDATIONS. 1488 Bond Street, Suite 100 <br /> MOP SINK E>aSIT1NG TO REMAIN EXISTING TO REMAIN 41.2 EXISTING TO REMAIN E3FISTING TO REMAIN _.._.-._- _ ..._. _ ._.__.. -SAN <br /> SANITARY SEWER (BELOW GRADE) Naperville, Illinois 60563-6503 <br /> EXISTING MOP SINK TO REMAfN 2" 1 1!4" 1I2" 112" - DOMESTIC COLD WATER (CWS) <br /> DOMESTIC HOT WATER (HWS) <br /> (P) 630.357.0540 (F) 630.357.0164 <br /> 2.1 1 3-COMP SINK 'GSW SE181f33D <br /> ILLINOIS LICENSE NO. 184-001442 <br /> 42.2 EQUIP 5PR-8W12 ADD ON PRE-RINSE ----- DOMESTIC HOT WATER RETURN (HWR) LEIL Comm. No. 24110029.000 <br /> 2" 1 114" 112" 1!2" COPYRIGHT 0 2017 <br /> TW- DOMESTIC TEMPERED HOT WATER <br /> 43 2 HAND SINK KRaV1fNE HS-1220 _ S-20-2-0.5 WALL. MOUNTED WITH 5103E SPLASHES <br /> 2" 1 114" 1f2" 1t23, --CD-- CONDENSATE DRAIN (BELOW GRADE) <br /> t NOTE' CD- CONDENSATE DRAIN (ABOVE GRADE} <br /> CLEANOUTS SHALL BE PROVIDED AT THE LOCATIONS INDICATED AND A MINIMUM WHERE REQUIREDGR <br /> BY CODE . FLOOR CLEANOUTS SHALL BE A MINIMUM OF 4" AND SHALL BE COMPLETE WITH A GREASE SEWER (BELOW GRADE) <br /> FLUSH PLUG AND REMOVABLE SCORIATED BRONZE FLOOR PLATE, PROVIDE CARPET BUTTONS IN -- -SCW- SOFT COLD WATER <br /> 46.1 1 2-COMP PREP SINK GSW <br /> S E 181828. 462 KROVti'NE <br /> 12-808L CARPETED AREAS. <br /> _T_ 2" 2.E 314" VENT <br /> GAS LINE (ABOVE GRADE) <br /> 15� POINT OF CONNECTION NEW <br /> 50 1 _ TO EXISTING <br /> GLASS FILLER EQUIP 5GF-W-F <br /> y _ POINT OF DISCONNECT. <br /> " 2 / " - GENERAL NOTES HB +- HOSE BIB <br /> 51 2 - - FS-1 (FLOOR SINK 1/2 GRATE) <br /> WATER FILTER SUPERB IF-C81710 - - I. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY FI <br /> 3 5 SINK DRAIN 85 <br /> BY ALL APPLICABLE CODES AND GOVERNING AUTHORITIES. WINGS A5 REQUIRED FD ® FLOOR DRAIN <br /> 2" 1 114" 112" DHD O HUB DRAIN <br /> T` BRASS <br /> B-3950 - _ 2. CONTRACTOR SHALL VERIFY AND CORRECT AS REQUIRED TO MEET ALL CODES AN TD TRE <br /> 2" 1 114" 112" REGULATIONS ANY POSSIBLE DISCREPANCIES BETWEEN TYPE AND SIZE OF CONNECTION ® NCH DRAIN <br /> 54 1 ICE MAKER BOX ICI=-O-MATIC ICEU220 _ SITE.SPECIFIED IN PLUMBING FIXTURE SCHEDULE AND FIXTURES ACTUALLY INSTALLED ON THE FLOOR CLEANOUT <br /> - <br /> - 2" 1 1l4" 112,E ----� CLEANOUT <br /> 3. ALL SANITARY PIPING SHALL HAVE A 1/8" PER FOOT SLOPE UNLESS OTHERWISE NOTED. EXTERIOR CLEANOUT n <br /> m <br /> 4. VENT PIPING SHOWN ON FLOOR PLANS IS ONLY INDICATIVE EXCEPT FOR VTR LOCATIONS. I HORIZONTAL CLEANOUT o <br /> a <br /> 5. VALVES AND FITTINGS SHALL BE OF SAME SIZE OF LINE ON WHICH THEY ARE LOCATED, ABBREVIATIONS N <br /> UNLESS OTHERWISE INDICATED ON DRAWINGS. <br /> 6. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES. AD ACCESS DOOR <br /> AFF ABOVE FINISHED FLOOR c <br /> 7. CONTRACTOR SHALL FIELD VERIFY ALL GIVEN MEASUREMENTS PRIOR TO LAYING AND APPROX APPROXIMATELY ° <br /> CONNECTING ALL SANITARY AND WASTE PIPING AND NOTIFY ARCHITECT OF ANY ARCH ARCHITECTURAL <br /> DISCREPANCIES. <br /> AUTO AUTOMATIC 0 <br /> BLDG BUILDING z <br /> ELD VERIFY ALL CONDITIONS 8. AIR CHAMBERS SHALL NOT BE CONSIDERED AN EQUAL TO WATER ARRESTORS AS SPECIFIED. ° <br /> CD CONDENSATE DRAIN C) <br /> 9. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING FIRE RATING AND WEATHERPROOFING CLG CEILING o <br /> NOTE! AS NOTED IN THE SPECIFICATIONS, ALL WIRING LAYOUTS, PIPING INTEGRITY OF ALL PIPING AND PENETRATIONS. <br /> CO <br /> C <br /> LAYOUTS AND DUCT LAYOUTS ARE SCHEMATIC. EXACT LOCATIONS SHALL BE CLEAN-OUT <br /> COND CONDENSATE q <br /> DETERMINED BY THE CONSTRUCTION AND STRUCTURE OF THE BUILDING 10. ALL WATER SUPPLY AND SANITARY LINES SHALL BE RUN AS CLOSE TO PLANS AS POSSIBLE OR CONDENSER <br /> AND SHALL BE VERIFIED AND COORDINATED IN THE FIELD. EACH TRADE WITH NO CHANGES IN SIZING. CONT CONTINUATION NO DATE REMARKS <br /> CONTRACTOR SHALL VERIFY WITH THE GENERAL CONTRACTOR THAT HE HAS <br /> CMU CONCRETE MASONRY UNIT REVISIONS c <br /> THOROUGHLY REVIEWED AND COORDINATED ALL LOCATIONS AND ROUTINGS 11. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY SUPPORTING DEVICES <br /> WITH ALL OTHER TRADES PRIOR TO FABRICATION OF CONDUITS, DUCTS, OR FOR ALL FIXTURES INCLUDED IN CONTRACT OR HEREIN SPECIFIED OR OTHERWISE. CW COLD WATER (CITY) <br /> PIPING, AND START OF INSTALLATION OF SAME (INCLUDING SPRINKLER <br /> EL ELEVATION z <br /> I ING WHEN PRESENT ON JOB). ANY INSTALLATION OR CONSTRUCTION 12. CHANGES IN THE DIRECTION OF SANITARY PIPING SHALL NOT BE MADE WITH FITTINGS WHICH ELEC <br /> WILL CAUSE EXCESSIVE REDUCTION IN THE VELOCITY OF FLOW OR CREATE ANY OTHER ELECTRIC � <br /> CONFLICTS WHICH OCCUR IN THE FIELD SHALL BE RESOLVED BY THE 'F DEGREES FAHRENHEIT <br /> TRADE CONTRACTOR TO THE SATISFACTION OF THE OWNER AND ARCHITECT ADVERSE EFFECT UNLESS PHYSICALLY IMPOSSIBLE (IE: USE OF SANITARY TEE IN A ° <br /> AND AT NO EXPENSE TO THE OWNER, ARCHITECT AND/OR GENERAL ECO EXTERIOR CLEANOUT <br /> HORIZONTAL CONNECTION, USE OF A DOUBLE SANITARY TEE 1N A VERTICAL STACK, IN ° <br /> CONTRACTOR. GENERAL, USE OF SHORT-RADIUS FITTINGS FOR BRANCH TO HOUSE DRAIN OR STACK FCO FLOOR CLEANOUT <br /> CONNECTION). FD FLOOR DRAIN <br /> THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER GAL GALLONS <br /> 13. ALL DRAINAGE PIPING SHALL BE MARKED WITH THE SEAL OF APPROVAL OF THE NATIONAL <br /> PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE SANITATION FOUNDATION. GPH GALLONS PER HOUR <br /> DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. <br /> CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER GPM GALLONS PER MINUTE c <br /> 14. PROVIDE ACCESS PANELS TO ALL VALVES WITHIN CHASES OR ABOVE NONACCESSIBLE ° <br /> BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS CEILINGS. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. HB HOSE BIBB <br /> COST. Ps <br /> HD HEAD <br /> 15. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF PLUMBING FIXTURE MOUNTING HW <br /> BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL HEIGHTS, AND DIMENSIONS. HOT WATER <br /> ODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS HR HOUR o <br /> ICH N 16. CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SANITARY LINES TO WHINV INVERT ELEVATION 0 <br /> FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING NEW SEWER <br /> LINES ARE TO BE CONNECTED BEFORE INSTALLATION OF NEW SEWER LINE, LBS POUNDS <br /> CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE ° <br /> CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY MIN MINIMUM <br /> 17. ALL VENTS THROUGH ROOF SHALL BE MIN. 10'-0" FROM ANY AIR INTAKES. neoktar <br /> APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN NC NORMALLY CLOSED <br /> INTENT. .�IJICE BAR <br /> 18. CONTRACTOR SHALL INSTALL DIELECTRIC UNIONS AT CONNECTIONS OF DISSIMILAR METALS, NIC NOT IN CONTRACT <br /> NO NORMALLY OPEN <br /> 19. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS (INCLUDING PIPE ROUTING AND EQUIPMENT NTS NOT TO SCALE <br /> LOCATIONS) TO ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL PRIOR TO THE 21 LINCOLN CENTER <br /> INSTALLATION OR PURCHASING OF ANY PIPING AND/OR EQUIPMENT. PSI POUNDS PER SQUARE INCH PVC POLYVINYL CHLORIDE STOCKTON, CALIFORNIA 95207 <br /> � <br /> R RISE <br /> c <br /> REQ'D REQUIRED o <br /> RM ROOM PROJECT NO: 2017,0599 <br /> SAN SANITARY DATE: 12,14.17 <br /> SPEC SPECIFICATION <br /> TEMP TEMPERATURE <br /> TYP <br /> TYPICAL Pool <br /> V VENT LINE <br /> �1_ <br /> VTR VENT THRU ROOF <br /> W/ WITH PLUMBING <br /> SPECIFICATIONS, SYMBOLS <br /> WCO WALL CLEANOUT AND ABBREVIATIONS <br /> CHECKED: MFGDRAWN: ADW <br />