2/2/2 <br />ABBREVIATIONS <br />@ <br />AT <br />FLA <br />FULL LOAD AMP <br />OLCP <br />OUTDOOR LIGHTING CONTROL PANEL <br />A, AMPS <br />AMPERES <br />G <br />GREEN GROUND WIRE <br />O.C. <br />ON CENTER <br />A.C. <br />ABOVE COUNTER <br />GND <br />GROUND <br />0 <br />PHASE <br />AF <br />AMPERE FRAME <br />GFI <br />GROUND FAULT INTERRUPTER <br />P <br />POLE <br />A.F.F. <br />ABOVE FINISH FLOOR <br />HID <br />HIGH INTENSITY DISCHARGE <br />P.A. <br />PUBLIC ADDRESS SYSTEM <br />AL <br />ALUMINUM CONDUCTOR OR BUS <br />HP <br />HORSEPOWER <br />PB <br />PULL BOX <br />ARCH <br />ARCHITECT <br />HPS <br />HIGH PRESSURE SODIUM (LAMP) <br />PNL <br />PANEL <br />AT <br />AMPERE TRIP <br />ILCP <br />INDOOR LIGHTING CONTROL PANEL <br />RS <br />RAPID START <br />ATS <br />AUTOMATIC TRANSFER SWITCH <br />I.B.O. <br />INSTALLED BY OTHERS <br />REC <br />RECEPTACLE <br />C <br />CONDUIT <br />I.B.E. <br />INSTALLED AND CONNECTED BY ELECTRICAL <br />RM <br />ROOM <br />CKT <br />CIRCUIT <br />c <br />� <br />CONTRACTOR <br />SPST <br />SINGLE POLE SINGLE THROWN <br />CAB <br />CABINET <br />JB <br />JUNCTION BOX <br />S. L. <br />SECURITY LIGHT, ON/OFF BY <br />CB <br />CIRCUIT BREAKER <br />KV <br />KILOVOLTS <br />PHOTO -ELECTRIC CELL <br />CO <br />CONDUIT ONLY (EMPTY CONDUIT) WITH PULL WIRE <br />KVA <br />KILOVOLT -AMPERES <br />SW <br />SWITCH <br />CU <br />COPPER CONDUCTOR OR BUS <br />KW <br />KILOWATTS <br />TS <br />TAMPER SWITCH <br />D <br />DEDICATED CIRCUIT <br />LV <br />LOW VOLTAGE <br />TEL <br />TELEPHONE <br />DN <br />DOWN <br />LTG <br />LIGHTING <br />TYP <br />TYPICAL <br />DPST <br />DOUBLE POLE SINGLE THROWN <br />MCA <br />MINIMUM CIRCUIT AMPACITY <br />TTB <br />TELEPHONE TERMINAL BOARD <br />DIA <br />DIAMETER <br />MCC <br />MOTOR CONTROL CENTER <br />TTC <br />TELEPHONE TERMINAL CABINET <br />EMT <br />ELECTRIC METALLIC TUBING <br />MOCP <br />MAXIMUM OVERCURRENT PROTECTION <br />U.C. <br />UNDER COUNTER <br />EWC <br />ELECTRIC WATER COOLER <br />MTD <br />MOUNTED <br />UG <br />UNDERGROUND <br />EM <br />EMERGENCY <br />MTG <br />MOUNTING <br />UON <br />UNLESS OTHERWISE NOTED <br />(E) <br />EXISTING <br />MLO <br />MAIN LUG ONLY <br />V <br />VOLTS/VOLTAGE <br />E.O.L. <br />END -OF -LINE DEVICE <br />N <br />NEUTRAL <br />VA <br />VOLT-AMPERE <br />F <br />FUSE <br />NEC <br />NATIONAL ELEC. CODE <br />W <br />WATTS <br />FS <br />FLOW SWITCH <br />NL <br />NIGHT LIGHT <br />WP <br />WEATHERPROOF <br />F.A. <br />FIRE ALARM <br />NIC <br />NOT IN CONTRACT <br />WM <br />WIREMOLD <br />FACP <br />FIRE ALARM CONTROL PANEL <br />NTS <br />NOT TO SCALE <br />XP <br />EXPLOSION PROOF <br />F.B.O <br />FURNISHED BY OTHERS/FURNISHED BY OWNER <br />SYMBOLS <br />(NOTE: NOT ALL SYMBOLS ARE USED IN DRAWINGS) <br />cR DUPLEX RECEPTACLE - 20A, 125V, GROUND <br />GFI DNOTES "GROUND FAULT INTERRUPTER" <br />wP WP DENOTES "WEATHERPROOF" <br />O <br />1x <br />3, <br />DOUBLE DUPLEX RECEPTACLE - (2) 20A, 125V, GROUND <br />SPECIAL RECEPTACLE - NEMA TYPE AS NOTED ON DWGS <br />(VERIFY NEMA TYPE WITH EQUIPMENT NAMEPLATE PRIOR TO ROUGH -IN) <br />+18" AFF, LION <br />CONFIRM HEIGHT OF RECEPTACLES AT <br />COUNTER PRIOR TO ROUGH -IN. <br />(VERIFY LOCATION AND HEIGHT OF <br />EQUIPMENT RECEPTACLES IN FIELD) <br />WALL SWITCH "ROCKER TYPE"- 20A, 120/277V, "a" INDICATES CONTROL. +48" AFF, UON <br />"D" INDICATES DIMMER - COMPATIBLE WITH LIGHTS PROVIDED <br />MANUAL MOTOR STARTER WITH OVER LOAD PROTECTION. SIZE PER CODE. <br />WALL MOUNTED <br />OCCUPANCY <br />SENSOR , APPLY PER <br />MANUFACTURER GUIDELINES. <br />JUNCTION BOX - <br />CEILING OR <br />WALL MOUNTED, SIZED <br />PER CODE. <br />DUCT SMOKE DETECTOR. PROVIDE 120V CONNECTION. <br />PANELBOARD <br />EDJ DISCONNECT SWITCH - MOTOR RATED AND FUSIBLE <br />- CONDUIT - CONCEALED IN CEILING OR WALL. <br />HASH MARKS INDICATE NUMBER PHASE (SHORT) AND NEUTRAL (LONG) WIRES. <br />UON, SIZE CONDUIT AND WIRE PER CODE. <br />T ISOLATED GROUND WIRE <br />�- GROUND WIRE WIRE, GREEN INSULATION. SIZE PER NEC U.O.N. <br />UP <br />CONDUIT - STUB -UP OR DOWN AS NOTED <br />DN <br />CONDUIT - HOME RUN TO PANEL, TERMINAL CABINET, ETC.: HASH MARKS <br />'#10 INDICATE NUMBER OF WIRES. "#10" INDICATES WIRE SIZE, SIZE CONDUIT <br />PER NEC U.O.N. PROVIDE J-BOX(ES)/SPLICE BOXES AS REQUIRED. <br />MINIMUM CONDUCTOR SIZE TO BE #12 AWG. <br />30A/3P CIRCUIT BREAKER (A: AMPACITY, P: No. OF POLE) <br />�y MOTOR FURNISHED AND INSTALLED BY OTHERS AND <br />IBJ CONNECTED BY ELECTRICAL CONTRACTOR <br />p DATA WALL OUTLET - PROVIDE RING WITH PULL WIRE <br />UP TO ACCESSIBLE CEILING SPACE U.O.N. <br />TELEPHONE WALL OUTLET - PROVIDE RING WITH PULL WIRE <br />UP TO ACCESSIBLE CEILING SPACE U.O.N. <br />1O SHEET NOTE #1 - SEE ASSOCIATED NOTE ON SAME SHEET <br />Al REVISION #2 - SEE ASSOCIATED REVISION NOTE <br />3 <br />REFERENCE TO PLAN/DETAIL/DIAGRAM #1 ON SHEET E-3 <br />�17 8:03:10 AM <br />CODE REFERENCE <br />ALL <br />WORK <br />SHALL COMPLY WITH FOLLOWING STATE CODES ALONG WITH <br />ANY <br />LOCAL <br />CITY AMENDMENTS <br />TO FIELD <br />AND/OR ORDINANCES, PUBLISHED UNDER <br />CALIFORNIA <br />CODE OF <br />REGULATIONS <br />(CCR), TITLE 24: <br />Part <br />1 <br />- 2016 <br />California <br />Administrative Code <br />Part <br />2 <br />- 2016 <br />California <br />Building Code, Volumes 1 and 2 <br />Part <br />2.5 <br />- 2016 <br />California <br />Residential Code <br />Part <br />3 <br />- 2016 <br />California <br />Electrical Code <br />Part <br />4 <br />- 2016 <br />California <br />Mechanical Code <br />Part <br />5 <br />- 2016 <br />California <br />Plumbing Code <br />Part <br />6 <br />- 2016 <br />California <br />Energy Code <br />PROGRAMMABLE TIME CLOCK TO MEET <br />REQUIREMENTS OF CALIFORNIA'S BUILDING ENERGY <br />EFFICIENCY STANDARDS. INSTALL TIMECLOCK AND <br />CONTACTORS IN A NEMA 1 ENCLOSURE. PROVIDE <br />WITH A LOCAL OVERRIDE PUSH BUTTON. <br />ELECTRICAL CONTRACTOR SHALL PROVIDE INITIAL <br />PROGRAMMING OF THE TIME CLOCK PER OWNER'S <br />REQUIREMENTS. <br />LIGHTING CONTROL DIAGRAM <br />SCALE: NONE <br />1. IT IS THE CONTRACTORS RESPONSIBILITY TO INSURE THAT THE INSTALLATION METHODS AND <br />MATERIALS FULLY CONFORM TO BUILDING CODES LISTED UNDER CODE REFERENCE ON THIS SHEET. <br />2. PROVIDE ALL LABOR, EQUIPMENT, DEVICES, AND INCIDENTAL MATERIALS AS SHOWN AND AS <br />REQUIRED FOR A COMPLETELY OPERATIONAL AND FUNCTIONAL ELECTRICAL SYSTEM. ELECTRICAL <br />CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO BID. ELECTRICAL CONTRACTOR SHALL <br />INCLUDE ALL COSTS NECESSARY FOR A COMPLETE AND FUNCTIONAL ELECTRICAL SYSTEM BASED <br />ON APPLICABLE CODES, DRAWINGS AND SPECIFICATIONS. <br />3. INSTALL ALL WORK NEATLY. RACEWAYS, FITTINGS AND EQUIPMENT: LEVEL, PLUMB AND STRAIGHT, <br />CONNECTORS, LOCKNUTS, SCREWS, CLAMPS: MADE UP TIGHTLY. CLEAR BEAMS OR OBSTRUCTIONS. <br />DO NOT CUT INTO OR REDUCE SIZE OF LOAD CARRYING MEMBERS. <br />4. TRADE COORDINATION: CHECK DRAWINGS AND WORK OF TRADES TO PREVENT INTERFERENCES. <br />5. DRAWINGS ARE DIAGRAMMATIC: REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF <br />OUTLETS, PLACEMENT OF LIGHTING FIXTURES, AND RECEPTACLES. <br />6. PROVIDE ALL MATERIALS NEW, PACKAGED IN ORIGINAL CONTAINERS, INSTALLED AND FREE OF <br />DEFECTS. ALL EQUIPMENT TO BE LISTED BY U.L. OR APPROVED EQUAL TESTING LABORATORY. <br />ALL RACEWAY SYSTEMS TO BE SUPPORTED INDEPENDENT OF SUSPENDED CEILING, INCLUDING BUT <br />NOT LIMITED TO POWER, TELEPHONE, DATA, AND LOW VOLTAGE WIRING SYSTEMS. <br />7. PROVIDE UL APPROVED FIRE PROOFING AT ALL PENETRATIONS THROUGH FIRE -RATED PARTITIONS. <br />8. PROVIDE BRACING OF ELECTRICAL EQUIPMENT TO MEET THE STATE OF CALIFORNIA REQUIREMENTS <br />FOR ZONE 4 EARTH QUAKE REGIONS. <br />9. ALL ELECTRICAL SWITCHBOARDS AND PANELS REQUIRING EXAMINATION OR SERVICING WHILE <br />ENERGIZED SHALL BE FIELD -MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL OF ARC FLASH <br />HAZARDS PER CEC 110.16. MARKING SHALL BE CLEARLY VISIBLE TO QUALIFIED PERSONS BEFORE <br />EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE. <br />10. ELECTRICAL EQUIPMENT AND DEVICES ASSOCIATED WITH BUILDING SIGNS, SUCH AS LAMP BALLASTS, <br />TRANSFORMERS, AND POWER SUPPLIES SHALL NOT BE LOCATED IN SOFFITS, MANSARDS AND <br />ATTICS. <br />11. ALL NEW CONDUITS AND CABLES SHALL BE CONCEALED, UNLESS OTHERWISE NOTED. <br />12. ALL EXISTING TO REMAIN LOADS TO BE KEPT ENERGIZED. ANY INTERRUPTION OF POWER SHALL BE <br />COORDINATED IN ADVANCE WITH OWNER. <br />13. PROVIDE CODE COMPLIANT TERMINATIONS AT PANELBOARDS, DISCONNECTS, CIRCUIT BREAKERS, <br />DEVICES, LIGHT FIXTURES, CONTROLLERS, AND MOTORS. FOLLOW MANUFACTURER'S <br />RECOMMENDATIONS FOR TORQUE VALUES. <br />14. USE #12 AWG MINIMUM WIRE WHEN SIZE IS NOT INDICATED ON DRAWINGS. SIZE CONDUIT PER <br />CODE. PROVIDE GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR IN ALL CIRCUITS. <br />15. REMOVE ALL DEBRIS RELATED TO ELECTRICAL CONSTRUCTION FROM PROJECT SITE ON A REGULAR <br />BASIS. <br />16. ELECTRICAL EQUIPMENT AND MATERIALS TO BE LISTED, LABELED, AND INSTALLED PER A <br />RECOGNIZED ELECTRICAL TESTING LABORATORY. <br />17. CONNECT T -BAR DROP-IN FIXTURES AT DIAGONAL CORNERS DIRECTLY TO STRUCTURE OVERHEAD <br />USING MINIMUM #1 WIRE. CLIPS ARE NOT SUITABLE IN SEISMIC ZONE #4. <br />18. THE AMPACITY OF THE CONDUCTOR SIZES, #14 THROUGH #1, SHALL BE RATED AT 60 DEGREES <br />CENTIGRADE. <br />19. <br />SEPARATE PERMIT REQUIRED FOR SIGNS <br />AND FIRE <br />ALARM SYSTEMS. <br />20. <br />ALL ELECTRICAL WORK TO BE SUBJECT <br />TO FIELD <br />INSPECTION. <br />21. ELECTRICAL CONTRACTOR (EC) SHALL CONFIRM IN FIELD PRIOR TO INSTALLATION THE METHOD OF <br />POWER CONNECTION TO EACH EQUIPMENT, WHETHER HARD -WIRED OR VIA RECEPTACLE. EC SHALL <br />COORDINATE ROUTING OF CONDUITS AND CIRCUITS TO FINAL CONNECTION POINT TO THE <br />EQUIPMENT WITH GENERAL CONTRACTOR AND/OR OWNER IN FIELD PRIOR TO INSTALLATION. EC <br />SHALL PROVIDE TRENCHING, INSTALLATIONS IN CABINETS AS REQUIRED TO PROVIDE REQUIRED <br />POWER CONNECTION TO EACH EQUIPMENT. <br />22. VERIFY FINISHES OF ALL DEVICES, COVER PLATES, AND LIGHT FIXTURES WITH ARCHITECT AND/OR <br />OWNER. <br />23. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIRE ALARM DESIGN AND INTERFACE WITH EXISTING <br />BUILDING FIRE ALARM SYSTEM. DETERMINE THE QUANTITY AND LOCATION OF DETECTION AND/OR <br />NOTIFICATION DEVICES NEEDED IN SUBWAY SPACE AND OBTAIN PERMIT FROM LOCAL <br />FIRE MARSHAL. <br />24. MOUNT ALL ELECTRICAL DEVICES, INCLUDING RECEPTACLES AND SWITCHES FLUSH TO SURFACE, <br />UNLESS NOTED OTHERWISE. <br />25. PROVIDE WARRANTY PERIOD OF ONE YEAR FOR ALL ELECTRICAL WORK. <br />26. ELECTRICAL CONTRACTOR SHALL HIRE THE SERVICES OF AN ACCEPTANCE TECH (AT) TO PROVIDE <br />INSTALLATION AND ACCEPTANCE DOCUMENTATION AS REQUIRED BY LOCAL AUTHORITY HAVING <br />JURISDICTION TO APPROVE LIGHTING FIXTURES AND LIGHTING CONTROLS. <br />ire <br />z <br />0 <br />w <br />w <br />..... <br />ca <br />a) <br />o <br />@ <br />co <br />O <br />N <br />� .5 <br />CV <br />Y <br />J <br />c i <br />� <br />a y <br />0) <br />Ec <br />00 <br />a)_Lu <br />c <br />a) U <br />z <br />o <br />C6 - a <br />E <br />c <br />v <br />t,- <br />,= <br />(Lw0M <br />w o <br />u� <br />as <br />) <br />` <br />a) <br />co <br />.9 <br />O N <br />� <br />N <br />a? <br />C <br />N O <br />Coo) <br />-j <br />cocoEc- <br />U <br />4 <br />O^ <br />O <br />8O <br />U <br />0) a) <br />a) <br />U) <br />)Q <br />' <br />(� <br />� a) <br />c6 > <br />-d <br />c <br />� <br />O <br />o_ L <br />LL <br />a <br />'o <br />M <br />U <br />J <br />c <br />..... <br />ca <br />a) <br />o <br />@ <br />DWG <br />O <br />N <br />ca <br />fc6 . V <br />Qi <br />Y <br />J <br />c i <br />� <br />2 a) a) <br />O 0 <br />a)_Lu <br />c <br />OrQ <br />o <br />C6 - a <br />E <br />v <br />t,- <br />,= <br />(Lw0M <br />W w i <br />O U) <br />F - <br />Z <br />LED <br />LU <br />w�Ll <br />L >H0)' <br />0f OC/)Q <br />CO Q00 <br />Ui, <br />Q �ofz <br />co I - 00I' <br />C/) Z i <br />J WVO <br />U <br />m F- <br />C.00 <br />U) <br />C <br />L <br />O~ <br />U <br />w <br />_1z0 <br />F= a <br />A�EET S. <br />�£ m <br />E 15692 z <br />E%P.6-30-16 /* <br />� OF CAUF� <br />DATE: <br />01117/2017 <br />JOB: <br />PTST-05 <br />DWG <br />BY: PSG <br />CHK <br />BY: PSG <br />E0.1 <br />