My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
1810
>
1600 - Food Program
>
PR0547120
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/12/2021 4:35:14 PM
Creation date
10/1/2021 1:39:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547120
PE
1624
FACILITY_ID
FA0026728
FACILITY_NAME
STARBUCKS COFFEE #5470
STREET_NUMBER
1810
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
1810 PACIFIC AVE
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6' -0" MAX, TYP. <br /> I GC TO PROVIDE 2" MIN <br /> SOFFIT PLASTIC GROMMET <br /> (2)#10 X 1.5" <br /> WOOD SCREWS, <br /> TYP. <br /> 1/2" GYP BD <br /> SEE 1/1103 FOR <br /> HEIGHT OF SOFFIT <br /> + + + + + + + + <br /> - WALL LED WALL GRAZER <br /> PENDANT LIGHT FIXTURE ©2011 STARBUCKS COFFEE <br /> SUPPORT OR SIMILAR <br /> SUPPORT <br /> STARBUCKS COFFEE <br /> FRAMINOG <br /> FRAMING COMPANY <br /> 4"X 18 GA. STEEL BRACING PENDANT LIGHT FIXTURE OR 2401 UTAH AVENUE SOUTH <br /> AT 48" O.C. (PROVIDE CONT. WALL FINISH- SIMILAR PENETRATION SEATTLE, WASHINGTON 98134 <br /> BRIDGING W/2410 SCREW TO WOOD SLATS WD0073 <br /> (206) 318-1575 <br /> EA. BRACE WHEN BRACE IS <br /> MORE THAN 12'-0" IN LENGTH). <br /> THESE DRAWINGS AND SPECIFICATIONS ARE <br /> CONFIDENTIAL AND SHALL REMAIN THE SOLE <br /> PROPERTY OF STARBUCKS CORPORATION, WHICH IS <br /> THE OWNER OF THE COPYRIGHT IN THIS WORK. <br /> LED WALL GRAZER DETAIL PLASTIC GROMMET THEY SHALL NOT <br /> IT REPRODUCED (IN USED IN <br /> p 4"X 18 GA. STEEL R /� PART), SHARED WITH THIRD PARTIES OR USED IN AN <br /> U 4"X 18 GA. STEEL BRACING STUDS 16" OC " T MANNER ON OTHER PROJECTS OR EXTENSIONS TO <br /> O AT 48" O.C. (PROVIDE CONT. @ Scale: 1 1/2"= 1'-0" Scale: 1/4"= 1'-0" THIS PROJECT WITHOUT THE PRIOR WRITTEN <br /> W/4#10 SCREWS <br /> m BRIDGING W/2410 SCREW TO TO (E)JOISTS. 5/8" GYP. BD, TYP CONSENT OF STARBUCKS CORPORATION. THESE <br /> _N EA. BRACE WHEN BRACE IS DRAWINGS AND SPECIFICATIONS ARE INTENDED TO <br /> MORE THAN 12'-0" IN LENGTH). TWO (2) NO. 12 GAUGE WIRES MUST BE LATERAL FORCE BRACING MEMBERS MUST BE EXPRESS DESIGN INTENT FOR A PROTOTYPICAL <br /> SECURED FROM LIGHT & MECHANICAL SPACED A MIN OF 6" FROM ALL HORIZONTAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE <br /> FIXTURES AT OPPOSING CORNERS PIPING OR DUCT WORK THAT IS NOT PROVIDED AT ANYTIME)AND DO NOT REFLECT ACTUAL SITE <br /> 06 -_ ALONG THE FIXTURE'S DIAGONAL. <br /> -------- W/ BRACING RESTRAINTS FOR HORIZ FORCES. CONDITIONS. NEITHER PARTY SHALL HAVE ANY <br /> U WIRES MAY BE SLACK. BRACING WIRES MUST BE ATTACHED TO THE OBLIGATION NOR LIABILITY TO THE OTHER(EXCEPT <br /> U GRID &TO THE STRUCTURE IN SUCH A MANNER STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS <br /> NOTE: ---------� THAT THEY CAN SUPPORT A DESIGN LOAD OF FULLY EXECUTED BY BOTH PARTIES. <br /> aI FOUR NO. 12 GAUGE WIRES MUST BE NOT LESS THAN 200 POUNDS OR THE ACTUAL <br /> O SECURED TO THE MAIN RUNNER WITHIN 2" LOAD, WHICHEVER IS GREATER, WITH A SAFETY <br /> 4"X 18 GA. STEEL BRACING OF THE CROSS RUNNER INTERSECTION FACTOR OF 2. ARCHITECT OF RECORD <br /> U? AT 48" O.C. (PROVIDE CONT. AND SPLAYED 90 DEGREES FROM EACH o °, <br /> X 4"X 18 GA LEDGER + 4"X 18 GA BRIDGING W/2410 SCREW TO + 4"X 18 GA OTHER AT AN ANGLE NOT EXCEEDING 45 <br /> m W/(2)#10 X 3" LONG + BLOCKING, TYP EA. BRACE WHEN BRACE IS + BLOCKING, TYP DEGREES FROM THE PLANE OF THE LIGHT FIXTURE > o • <br /> WOOD SCREWS AT (LESS THAN 56 LBS) <br /> �I EACH D STUD, TYP. + MORE THAN 12'-0" IN LENGTH). + CEILING. (MAY BE SLACK) <br /> c� e ' NO. 12 GAUGE N <br /> 00 WIRES WITHIN 3" OF ---------- <br /> ALL 4 CORNERS. <br /> ---------ALL4CORNERS. mcg architecure <br /> N �. <br /> �. <br /> °"` `'e =-" "'° �� � '" '' ` PROVIDE MINIMUM OF 2 SCREWS AT <br /> OS OPPOSITE CORNERS OF SUPPORT 15635 Alton Parkway, Suite 100, Irvine, CA 92618 <br /> N �- NOTE: P:949.553.1117 F:949.474.7056 <br /> N 4"X 18 GA. STEEL STUDS AT 16" WIRES, SCREW ON T-BAR PROVIDE EARTHQUAKE <br /> � #10 SMS AT EACH (4)#10 SMS. O.C. WITH 4-#10 SCREWS, TYP SAFETY CLIPS AT SIDES OR ENDS. CLIPS &WIRES AS REQ'D. <br /> U SIDE AND EACH STUD. TYP. ARCHITECT STAMP <br /> SEE 1/1-1107 FOR <br /> 0 5/8" GYP. BD, TYP HEIGHT OF SOFFIT c�ED A C <br /> G'- �,E WINyj> <br /> SUSPENDED <br /> N CEILING GRID n <br /> 1839 <br /> 0 9/ <br /> a �SO <br /> FIT DETAIL 7 CEILING LIGHT DETAIL �,� <br /> N 2 - 1 -0 scale: 3/8" = V-0" DF CALIFO <br /> U) <br /> N VERTICAL STRUT @ 12" O.C. MAX. EACH COMPRESSION STRUT GUIDELINES <br /> 73 WAY WITH FIRST POINT TO BE WITHIN 6" NOTE: <br /> cn FROM EACH WALL FASTENED TO MAIN 8 GA HANGER WIRE TO VERIFY ASSEMBLY WITH TRUSS COMPRESSION STRUT SIZE MAXIMUM LENGTH <br /> RUNNER & STRUCTURE ABOVE @ 4'-0" MFG WHERE 1 HR ASSEMBLY IS <br /> STRUCTURE ABOVE PER ASCE-7 13.5.6.2.2 A OC NW/4 WIRES SPLAYED 90 REQ'D 3/4" DIAMETER STRUT 12'-0" <br /> () • • • deg IN 4 DIRECTIONS (45° <br /> rj o MAX FROM CEILING PLANE) 1" DIAMETER STRUT 18'-0" <br /> U 12 GA. VERTICAL cm SINGLE 2 1/2"x 20 GAUGE METAL STUD (I MIN. = 0.18") 11'-6" <br /> HANGER WIRE AT 4'-0" 90° 90° TYPE "S" SCREW <br /> Q EACH — t • • 2'-0" @ 8" OC BACK-TO-BACK 2 1/2"x 20 GAUGE METAL STUD SCREWED 15'-0" w <br /> p WAY WITH MIN. 3 TIGHT MAX TOGETHER @ 24" O.C. <br /> TURNS 1-1/2"AT BOTH 20 GAUGE J <br /> ENDS OF WIRE (TYP.) U FURRING HEAVY DUTY T-BAR SYSTEM ^^ <br /> z ° PER ASTM AC 635 &ASTM AC 12 GA WIRE HANGER @ 48" O.C. <br /> Q 0 636. SEC 1613.1 CBC. L.L CV <br /> o CHANNEL @ EA. WAY. FIRST POINT TO BE 8" < LULO <br /> U 24" OC / FROM WALL. <br /> CROSS RUNNERS C <br /> VERTICAL COMPRESSION STRUT G <br /> 0 0 AND BRACING WIRES @ 12'-0" O.C. <br /> U p / 0 MAX. EACH WAY. FIRST POINT TO t.! U <br /> �O � fi fi • 0 BE WITHIN 6'-0" FROM EACH WALL. W LL z <br /> U)� 20 GAUGE WIRE 4S0 FASTENER TO MAIN RUNNER & LU Q <br /> U <br /> STRUCTURE ABOVE WITH 1/4" O <br /> X 2 0 ` R� \�'I' MACHINE BOLTS. SEE NOTE 4. z Q Q <br /> MAIN RUNNERS 0 1-1/2" 20 GAUGE <br /> I 2" MAX. FROM BRACING <br /> °6 <br /> COLD ROLLED WIRES TO CROSS TEES W W O U 8" MAX STEEL @ 48" OC O Q O <br /> v 12 GA. BRACING WIRE WITH MIN. — <br /> BRACING WIRES TO BE ATTACHED <br /> L) 4 TIGHT TURNS IN 1-1/2"AT , 00 <br /> - <br /> d BOTH ENDS OF WIRE (TYP.)AT 00 GYP, ALL EDGES �� TIGHT TURNS IN 1-1/2" @ BOTH D- Q_ U) <br /> 6'-0" 12 0 OC 5/8" FIRE-RATED �, <br /> I EACH VERTICAL STRUT MAX SUPPORTED � @ MAX O ALL BRACINGWIRETOYP � � <br /> O .75 AT TWO ADJACENT GYPSUM BOARD DETAIL x S O C G <br /> NOTES: WALLS. SEE NOTE 2 6 MAIN RUNNER @ 4'-0" O.C. STORE #: 5470 <br /> REFLECTED CEILING PLAN scale: 1/4" = V-0" <br /> X 1. SUSPENDED ACOUSTICAL CEILING SYSTEM SHALL BE PROJECT #: 03030-052 <br /> m INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF SHIM AS NEEDED LARR#25764 CASEWORK CONCEPT: CORE <br /> WI ASTM C 635 AND ASTM C 636. -------- ICC ER#1222 ISSUE DATE: CHECKSET 2-10-20 <br /> j CROSS TEE @ 2'-0" O.C. <br /> u7 2. BRACING WIRES SECURED TO MAIN RUNNERS WITHIN 2" OF LINE OF WALL PROGRAM MANAGER: M.DREBIKA <br /> ap 6'-0" MAX. 6'-0" MAX. OR V-0" O.C. AS SHOWN <br /> THE CROSS RUNNER INTERSECTION AND SPLAYED 90° FROM 12' -0" MAX. 12'-0" MAX. STORE DESIGNER: M.DREBIKA <br /> EACH OTHER AT AN ANGLE NOT EXCEEDING 45° FROM THE ATTACHMENT CLIP NOTES: LEED(:DAP: N/A <br /> X PLANE OF THE CEILING 1. ALL 24"X48" CEILING LIGHT FIXTURES &24"X24" HVAC AIR REGISTERS SHALL BE <br /> 8" MAX 8" MAX CHECKED BY: A.FELDMAN <br /> m MAIN TGRID (USG SUPPORTED BY A MINIMUM OF (2) HANGERS @ OPPOSITE CORNERS. CEILING SYSTEM SHALL <br /> T- <br /> GRID 3. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF NOT SUPPORT OTHER ITEMS. MCG PROJECT#: 18531 <br /> O THE CEILING GRID SHALL BE ATTACHED TO A MINIMUM 2"WIDE DX26, MCG PROJ. MANAGER: C.LEE <br /> O CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL BLACK COLOR) 2. ALL INTERIOR WALL& CEILING FINISHES SHALL BE INSTALLED TO CLASS III FLAME SPREAD. <br /> j W Lu <br /> j DIRECTION SHALL HAVE 0.75" CLEARANCE FROM THE WALL AND U) ~ MCG PROJ. SPECIALIST: SPARK <br /> O �, NO. 12 GA MIN <br /> N SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE z VERTICAL HANGER 3. 45 DEGREE BRACE WIRES &COMPRESSION STUDS ARE TO BE PROVIDED ONLY IF <br /> 0 ANGLE. WIRE, SEE NOTE 3 REQUIRED BY LOCAL BUILDING DEPARTMENT. Revision Schedule <br /> d <br /> 00 4. WHEN THE DISTANCE BETWEEN THE STRUCTURAL DECK AND = > ', O O 4. COMPRESSION STRUTS : STEEL SECTION ATTACH TO MAIN RUNNERS WITH 1/4" MACHINE Rev Date By Description <br /> THE CEILING EXCEEDS 4", THE SPACING OF THE VERTICAL ACOUSTICAL TILE J BOLT AND TO STRUCTURE WITH 3/16" DIAMETER POWER DRIVEN STUD. COMPRESSION STRUT <br /> CN HANGERS SHALL NOT EXCEED 2' O.C. ALONG THE ENTIRE MEANS T_ CEILING ON SUSPENDED .75"AT TWO SHALL NOT REPLACE HANGER WIRE. <br /> OF EGRESS SERVICING THE OCCUPANT LOAD OF 30 OR MORE, _j GRID SYSTEM ADJACENT WALLS <br /> AND AT LOBBIES ACCESSORY TO GROUP A OCCUPANCIES. = SEE NOTE 2 5. BRACING WIRES SECURED TO MAIN RUNNERS WITHIN 2" OF THE CROSS RUNNER <br /> — COMPRESSION STRUT CEILING PANEL INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING <br /> 5. EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATER z 45 DEGREES FROM THE PLANE OF THE CEILING. <br /> 73 DEFLECTIONS, SPRINKLER HEADS AND OTHER PENETRATIONS, E: \ — 2" MIN WALL ANGLE <br /> SHOW A 2" OVERSIZED RING, SLEEVE OR ADAPTER THROUGH . <br /> 6. CLOSURE ANGLE SHALL BE A MINIMUM OF 2" SHEET TITLE: <br /> O THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST GRID) LLED 1/4" BELOW MAIN CEILING DETAILS <br /> N 1" IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY A SWING 7. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS THAN <br /> 0o JOINT THAT CAN ACCOMMODATE 1" OF CEILING MOVEMENT IN SECTION THROUGH ROOM PROVIDE COMPLETE 2" IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE <br /> �Ci ALL HORIZONTAL DIRECTIONS IS PERMITTED TO BE PROVIDED AT INSTALLATION AS RECOMMENDED ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION <br /> THE TOP OF THE SPRINKLER HEAD EXTENSION. PER ASCE 7-05, BY MANUFACTURER AND CODES SHALL HAVE A 0.75" CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SCALE:AS SHOWN <br /> N SEC 13.5.6.2.2. <br /> SLIDE ON A CLOSURE ANGLE. <br /> O SHEET NUMBER: <br /> N 17�S.alel/8! <br /> CAL SUSPENDED CEILING VERTICAL & LATERAL SUPPORT 5 T-BAR TO WALL DETAIL T-BAR CEILING DETAIL 1505 <br /> N <br /> c j = 1'-0" <br /> scale: 6" = 1'-0" scale: 1/4" = 1'-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.