Laserfiche WebLink
©2017 STARBUCKS COFFEE COMPANY <br /> STARBUCKS COFFEE <br /> COMPANY <br /> 2401 UTAH AVENUE SOUTH <br /> SEATTLE,WASHINGTON 98134 <br /> (206)318-1575 <br /> THESE DRAWINGS AND SPECIFICATIONS ARE <br /> CONFIDENTIAL AND SHALL REMAIN THE SOLE <br /> PROPERTY OF STARBUCKS CORPORATION, <br /> WHICH IS THE OWNER OF THE COPYRIGHT IN <br /> 6„ THIS WORK. THEY SHALL NOT BE <br /> REPRODUCED(IN WHOLE OR IN PART), SHARED <br /> WITH THIRD PARTIES OR USED IN ANY MANNER <br /> m,.., ON OTHER PROJECTS OR EXTENSIONS TO THIS <br /> PROJECT WITHOUT THE PRIOR WRITTEN <br /> CONSENT OF STARBUCKS CORPORATION. <br /> YA,1__WALL � <br /> BEHIND ANSFC��FP THESE DRAWINGS AND SPECIFICATIONS ARE <br /> PR/MARY CONDUCTORS a INTENDED TO EXPRESS DESIGN INTENT FOR A <br /> /N FLEX/BLE METALLIC ---DRY-TYPE TRANSFORMER PROTOTYPICAL STARBUCKS STORE(WHICH IS <br /> CONDUIT To SUBJECT TO CHANGE AT ANYTIME)AND DO <br /> PANELBOARD NOT REFLECT ACTUAL SITE CONDITIONS. <br /> NEITHER PARTY SHALL HAVE ANY OBLIGATION <br /> SECONDARY CONDUCTORS NOR LIABILITY TO THE OTHER(EXCEPT STATED <br /> IN FLEX/BLE METALLIC ABOVE)UNTIL A WRITTEN AGREEMENT IS <br /> CONDUIT TO PANELBOARD METAL COLD WATER m m METAL HOT WATER FULLY EXECUTED BY BOTH PARTIES. <br /> PIPE, SEE NOTE 9� N PIPE, SEE NOTE 9 <br /> 3 4" CHAMFER MASON INDUSTRIES NO SER/ES BOND/NG ARCHITECT OF RECORD <br /> NEOPRENE V/BRA 77ON /SOLA TOR <br /> FOR TRANSFORMERS MOUNTED BUSH/NG, mcg architecture <br /> ABOVE SLAB ON GRADE; SECURE SEE NOTE 1-\ GROUND B U S <br /> TRANSFORMER TO WERA T/ON <br /> °a <br /> ISOLATOR, /F APPLICABLE, AND To U77L/TY o - <br /> TRANSFORME;:�XGC <br /> CSST FUEL GAS <br /> 3" 1N/CK CONCRETE HOUSEKEEPING SECURE V/BRA T10N ISOLA TOR TO 'L <br /> PAD; PAD SHALL EXTEND 3" HOUSEKEEPING PAD; TYPICAL OF SSBJ PIPING, SEE NOTE 10cc <br /> BEYOND TRANSFORMER ON SIDES FOUR NEUTRAL BUS <br /> AND FRONT AND SHALL EXTEND 6" SERVICE <br /> BEYOND TRANSFORMER /N REAR CONDUCTOR AWG 111 Pacifica,Suite 280,Irvine,CA 92618 <br /> CONDO/T_ P:949.553.1117 F:949.474.7056 <br /> SERV/CE DISCONNECT/NGLd <br /> ENGINEER STAMP FESSMEANS, SEE NOTE 7 COMMUN/CA TIONSrr M14"L 4'rr <br /> AWG SYS7EM(S) GROUND Quo ioN� <br /> TRANSFORMER MOUNTING DETAIL <br /> WATER BUSBAR, SEE NOTE 11 �o �y ROY SC Fy <br /> o 44.1 <br /> J7 METER <br /> NOT TO SCALE / <br /> a0a No. E14631 r m <br /> O EXPOSED METAL � <br /> NOTE 3 NOTE 2 SUPPORT STRUCTURE, <br /> DIELECTR/C (TYPICAL) <br /> SEE NOTE 8 9 �eCrR 1cP� �\P <br /> UNION GRADE TF OF' CAL\FO <br /> -MRm CONDUCTOR SCHEDULE <br /> METAL UNDERGROUND <br /> SCHEDULECONDUCTOR <br /> PIPE 80 PVC w MARK DESCRIPTION SIZED PER Date. 03/24/2020 <br /> z SLEEVE w n w STING GC GROUNDED CONDUCTOR (NEUTRAL) SEE ONE-LINE DIAGRAM <br /> CONDUCTOR SCHEDULE ��10'-0" MIN. m u wu mwA. <br /> m M u w ' Lw u µwR w ' GEC-1 GROUNDING ELECTRODE CONDUCTOR NEC TABLE 250.66 <br /> onn mumuµ µLQ _ m u GEC-2 GROUNDING ELECTRODE CONDUCTOR #4 AWG <br /> MARK DESCRIP11ON SIZED PER <br /> GROUND ROD, o u _ GEC-3 GROUNDING ELECTRODE CONDUCTOR #6 AWG <br /> EGC EQUIPMENT GROUNDING CONDUCTOR NEC TABLE 250.122 SEE NOTF 6 _ µum M wu u `_ n w L - yinµ ,$-'- 4 n <br /> GC GROUNDED CONDUCTOR (NEUTRAL) SEE ONE-LINE DIAGRAM "� - MBJ MAIN BONDING JUMPER NEC TABLE 250.102(C)(1) <br /> SSBJ SUPPLY-SIDE BONDING JUMPER NEC TABLE 250.102(C)(1) <br /> GROUNDING REQUIREMENTS FOR SINGLE GEC GROUNDING ELECTRODE CONDUCTOR NEC TABLE 250.66 METAL /N-GROUND z <br /> PHASE SYSTEMS ARE IDENTICAL TO CONCRE7F ENCASED <br /> THE REQUIREMENTS FOR THE THREE SBJ SYSTEM BONDING JUMPER NEC TABLE 250.102(C)(1) SUPPORT STRUCTURE, ELECTRODE, SEE NO TF 4 <br /> SEE NO TE 5 01 <br /> PHASE SYSTEM SHOWN IN THIS DETAIL SSBJ SUPPLY-SIDE BONDING JUMPER NEC TABLE 250.102(C)(1) SECONDARY SIDE <br /> WPBJ WATER PIPING BONDING JUMPER NEC TABLE 250.102(C)(1) DISTRIBUTION EQUIPMENT 0 <br /> GL7IERAL MD7£S APPLIC4ME TD THIS DETAIL• w N <br /> TRANSFORMER A. ALL REFERENCES TO THE NA TIONAL ELECTRICAL CODE (NEC) ON THIS DETAIL REFER TO THE 2017 EDITION OF THE NEC (NFPA 70-2017). J N <br /> B. PHASE CONDUCTORS ARE NOT SHOWN. <br /> BOND THE METAL WA TER PIPING <br /> NEUTRAL BAR C. CONDUCTORS ARE COPPER UNLESS NOTED OTHERWISE. L.L W <br /> TO THE BOND/NG JUMPER US/NG DO NOT BOND NEUTRAL MOTES APPYICABLE TO THIS DETAIL' . . Q <br /> A GROUND CLAMP AND GROUND IN THIS 1. PROVIDE A BONDING BUSHING ON ALL METAL CONDUITS CONTAINING SERVICE CONDUCTORS PER NEC SECTION 250.92(B)(4) REQUIREMENTS AND PROVIDE A V <br /> METAL WA TER 0 O 00 0 O SECONDARY EQU/PMENT 2. WHERE EXPOSED OTO PHYSICAL DAMAGE,NDING JUMPER SIZED PER <br /> NCLOSE GROUNDING NEC TABLE 250. 1 ELECTRODE CONDUCTORS IN SCHEDULE 80 PVC CONDUIT PER NEC SECTION 250.64(B) REQUIREMENTS. ,�( C/) U_ <br /> PIPING IN THE AREA EQU/PMENT bi 06 Q LL z <br /> OVERCURRENT � A. WHERE SCHEDULE 80 PVC CONDUIT CANNOT BE USED, SUCH AS IN PLENUM CEILINGS, ENCLOSE CONDUCTORS IN RIGID METAL CONDUIT. PROVIDE A BONDING <br /> X1 X2 X 0 X3 PROTECTION GROUND BAR BUSHING A T EACH END PER NEC SECTION 250.64(E)(1) AND PROVIDE SUPPL Y-SIDE BONDING JUMPER WHICH IS THE SAME SIZE AS THE ENCLOSED Q 1 p U 0 <br /> DEVICE <br /> m m GROUNDING ELECTRODE CONDUCTOR PER NEC SECTION 250.64(E)(3) REQUIREMENTS. Z Q <br /> BUILDING N J. PER NEC SECTION 250.52(A)(1), CONNECT TO THE BUILDINGS METAL UNDERGROUND WA TER PIPE THAT IS IN DIRECT CONTACT WITH THE EARTH FOR A MINIMUM Q <br /> STRUCTURAL TO PRIMARY 0 0 0 0 0 0 0 0 cn , , V U. L} <br /> DISTRIBUTION POINT OF 10 FEET IF PRESENT. PER NEC SECTION 250.68(C)(1) REQUIREMENTS THE CONNECTION SHALL BE MADE WITHIN 5 FEET OF THE WATER PIPE S ENTRANCE <br /> STEEL $�`�`;�BE INTO THE BUILDING AND A JUMPER SHALL BE PROVIDED AROUND ANY WATER METER AND DIELECTRIC UNIONS. JUMPER SHALL BE THE SAME SIZE AS THE w � w U <br /> H 3 H 1 H 2 GROUNDING ELECTRODE CONDUCTOR CONNECTING TO THE WA TER PIPE. U 0 0 <br /> TTT 4. PER NEC SECTION 250.52(A)(3) REQUIREMENTS, PROVIDE A GROUNDING ELECTRODE ENCASED IN AT LEAST 2" OF CONCRETE AND LOCATED NEAR THE BOTTOM OF A 0 O r <br /> . <br /> m v a CONCRETE FOUNDA TION OR FOOTING THA T IS IN DIRECT CONTACT WITH EARTH. GROUNDING ELECTRODE SHALL CONSIST OF A T LEAST 20 FEET OF ONE OR MORE /� CO <br /> v w w w O O 0 O TRANSFORMER SECONDARY BARE OR ZINC GAL VANIZED OR OTHER ELECTRICALL Y CONDUCTI VE COA TED STEEL REINFORCING BARS OR RODS OF NOT LESS THAN 1/2" IN DIAMETFR OR A MINIMUM 11 r CIS <br /> w Q Q Q ® ® ® CONDUCTORS SHALL NOT EXCEED OF 20 FEET OF AWG BARE COPPER CONDUCTOR. THIS CONCRETE-ENCASED ELECTRODE IS ALSO KNOWN AS A "UFER" GROUND. <br /> BOND THE BUILDING = __ m HASE A ' <br /> STRUCTURAL STEEL TO THE a cn 25-0 /N TOTAL LENGTH PER 5. PER NEC SECTION 250.52(A)(2) REQUIREMENTS, PROVIDE A GROUNDING ELECTRODE CONDUCTOR TO ONE METAL IN-GROUND SUPPORT STRUCTURE THAT IS IN DIRECT STORE #: 5470 <br /> PHASE B NEC SECT7ON 240.21(C)(6) CONTACT WITH THE EARTH VERTICALL Y FOR 10 FEET OR MORE, IF PRESENT, AND BOND I T USING A UL LISTED IRREVERSIBLE CLAMP OR WELDED LUG. <br /> GROUND/NG ELECTRODE HASE C 6. PROVIDE A T LEAST ONE SUPPLEMENTAL GROUNDING ELECTRODE IN THE FORM OF A 10 FOOT LONG BY 3/4" DIAMETER COPPER GROUND ROD INSTALLED PER NEC <br /> CONDUCTOR US/NG A UL <br /> GC ARTICLE 250 REQUIREMENTS. PROJECT#: 03030-052 <br /> LISTED IRREVERSIBLE CLAMP <br /> SSBJ 7. WHEN THE SERVICE CONSIST' OF MUL TIPLE DISCONNECTING MEANS IN SEPARATE ENCLOSURES, CONNECT A TAP CONDUCTOR FROM THE MAIN GROUNDING ELECTRODE <br /> OR LUG; CONNECT TO <br /> GROUND/NG ELECTRODE CONDUCTOR TO EACH DISCONNECTING MEANS. SIZE THIS TAP BASED ON THE LARGEST SERVICE CONDUCTOR IN THAT SERVICE DISCONNECT ENCLOSURE. CASEWORK CONCEPT: CORE <br /> SYSTEM AT THE SERVICE SBJ .......m. 8. PER NEC SECTION 250. 104(C)(2), BOND EXPOSED STRUCTURAL METAL BUILDING FRAME, IF PRESENT, TO THE GROUNDED CONDUCTOR AT THE SERVICE. PER NEC ISSUE DATE: CHECKSET 2-10-20 <br /> ENTRANCE WHEN STRUCTURAL WPBJ SECTION 250.68(C)(2), THIS STRUCTURAL FRAME IS PERMITTED TO BE USED AS A GROUNDING ELECTRODE CONDUCTOR. PROGRAM MANAGER: M. DBREBIKA <br /> STEEL IS NOT PRESENT GEC 9. PER NEC SECTION 250. 104(A), BOND THE METAL WATER PIPING SYSTEM TO THE METAL BUILDING FRAME. <br /> 10. PER NFPA 54-2018 SECTION 7. 12.2, BOND CORRUGATED STAINLESS STEEL TUBING (CSST) FUEL GAS PIPING, IF PRESENT, TO THE GROUNDING ELECTRODE STORE DESIGNER: M. D B RE B I KA <br /> SYSTEM. THE BONDING CONDUCTOR SHALL NOT EXCEED 75 FEET IN LENGTH PER NFPA 54-20 18 SECTION 7. 12.2.3. LEED®AP: N/A <br /> WHERE EXPOSED TO PHYS/CAL PROVIDE TERM/NAL BAR PER NEC 11. PER NEC SECTION 250.94(B), PROVIDE BURNDY#BCB14412ST, OR EQUAL, 1/4" THICK BY 4" NIDE BY 12" LONG COPPER GROUND BUSBAR, INCLUDING ALL <br /> DAMAGE, ENCLOSE CONDUCTORS SECTION 450.1O(A) REQUIREMENTS BRACKETS, INSULATORS, AND PLEXIHE GLASS COCOVER, AT TMAIN COMMUNICATIONS SYSTEM ENTRANCE FOR BONDING THE COMMUNICATIONS SYSTEMS TO THE CHECKED BY: A. FELDMAN <br /> /N SCHEDULE 80 PVC CONDUIT BUILDING'S GROUNDING ELECTRODE SYSTEM. MCG PROJECT#: 18531 <br /> MCG PROJ. MANAGER: C. LEE <br /> MCG PROJ. SPECIALIST: S.PARK <br /> TRANSFORMER GROUNDING AND BONDING DETAIL 1 SERVICE ENTRANCE GROUNDING AND BONDING DETAIL Revision Schedule <br /> 2 NOT TO SCALE I NOT TO SCALE Rev Date By Description <br /> SHEET TITLE: <br /> ELECTRICAL DETAILS <br /> SCALE:AS SHOWN <br /> Schnackel <br /> eNinem® SHEET NUMBER: <br /> Newyork a Omaha a LoacAr4pks o Seattle o Hondtdu <br /> 800-581-0963 wwwJwhmK aeL00m <br /> 80 South Lake Avenue, Suite 640 Pasadena, CA 91101 E-6002 <br /> SE JOW: 181103 <br />