Laserfiche WebLink
©2017 STARBUCKS COFFEE COMPANY <br /> ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ----------------------------- STAR CKS COFFEE <br /> COMPANY- <br /> 2401 UTAH AVENUE SOUTH <br /> SEATTLE WASHINGTON 98134 <br /> 2 <br /> ( 06)318 <br /> 1575 <br /> Y <br /> THESE DRAWINGS AND SPECIFICATIONS ARE <br /> ' CONFIDENTIAL AND SHALL REMAIN THE SOLE <br /> >> <br /> PROPERTY OF STARBUCKS CORPORATION <br /> WHICH IS THE OWNER OF THE COPYRIG <br /> HT IN <br /> .. <br /> THIS WORK. THEY SHALL NOT BE <br /> I REPRODUCED (IN WHOLE OR IN PART), SHARED <br /> EF-1 WITH THIRD PARTIES OR USED IN ANY MANNER <br /> 70' EXHAUST 3 ON OTHER PROJECTS OR EXTENSIONS TO THIS <br /> COND-1 O4 CLE-A R%NCE PROJECT WITHOUT THE PRIOR WRITTEN <br /> CONSENT OF STARBUCKS CORPORATION. <br /> I THESE DRAWINGS AND SPECIFICATIONS ARE <br /> - <br /> INTENDED TO EXPRESS DESIGN INTENT FORA <br /> PROTOTYPICAL STARBUCKS STORE(WHICH IS <br /> \ SUBJECT TO CHANGE AT ANYTIME)AND DO <br /> NOT REFLECT ACTUAL SITE CONDITIONS <br /> NEW RT — _ \ NEITHER PARTY SHALL HAVE ANY OBLIGATION <br /> 0NEW RTU-1 O 6 TON U 2 O 6 TON RTU—3 \ NOR LIABILITY TO THE OTHER(EXCEPT STATED <br /> 5 TON <br /> CARRIER 48HC CARRIER 48HC CARRIER 48HC ABOVE) UNTIL A WRITTEN AGREEMENT IS <br /> 2 FULLY EXECUTED BY BOTH PARTIES. <br /> 2 2 \ / <br /> z z z <br /> ARCHITECT OF RECORD <br /> / me architecture <br /> o -o <br /> � C -j <br /> L <br /> -=: <br /> ------------------------------------------------------ <br /> co <br /> ------------------------------------------------- <br /> ___ _________________________ _________ _________________________ _________________________________________ 111 Pacifica,Suite 280, Irvine,CA 92618 <br /> ---------------------------------------------------------------------------------------------------------------------------- <br /> P: 949.553.1117 F:949.474.7056 <br /> ENGINEER STAMP QROFESS/oN <br /> _______- <br /> -------------------------------------------------------------- <br /> p o�y FtoY SC, <br /> cD z <br /> w No. M33299 m <br /> FCHAN 1 CPQ �P <br /> 9TF 0 <br /> CAS <br /> Date. 03/24/2020 <br /> ----------------------------------------------------------------------------------------------------------------- <br /> CD <br /> <:. <br /> = Z <br /> Z _ Q Q � <br /> MECHANICAL GENERAL NOTES MECHANICAL PLAN NOTES w w U <br /> ROOF PLAN A. EXISTING CONDITIONS ARE BASED ON RECORD DRAWINGS PROVIDED BY THE OWNER. O PROVIDE NEW CARRIER ROOFTOP UNIT AS SCHEDULED ON SHEET M-0001. Q <br /> CD 0 <br /> CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE � � � � (n <br /> 1 scale: 1/4"= 1'-a" N 2 VERIFY UNITS ARE EQUIPPED WITH FACTORY MOUNTED SMOKE DETECTOR. <br /> PROJECT. Q <br /> B. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE GOVERNMENT AND O PROVIDE NEW ROOF MOUNTED EXHAUST FAN AS SCHEDULED ON SHEET M-0001. STORE #: 5470 <br /> LOCAL CODES. FIELD VERIFY FINAL LOCATION IS A MINIMUM OF 10'-0"FROM THE NEAREST PROJECT#: 03030-052 <br /> OUTDOOR AIR INTAKE. <br /> C. MECHANICAL CONTRACTOR SHALL FIELD COORDINATE WITH ELECTRICAL CONTRACTOR FOR CASEWORK CONCEPT: CORE <br /> ALL POWER REQUIREMENTS. O INSTALL REMOTE CONDENSING UNIT COND-1 FOR ICE MACHINE,SEE ARCHITECTS <br /> SHEET FOR FURTHER INFORMATION. INSTALL REFRIGERANT LINE SET ISSUE DATE: CHECKSET 2-10-20 <br /> D. THE CONTRACTOR SHALL COOPERATE WITH THE OTHER TRADES SO THAT THE INSTALLATION THERMOSTATIC EXPANSION VALVE, SOLENOID VALVE,TEMPERATURE CONTROL, PROGRAM MANAGER: M. DBREBIKA <br /> OF ALL EQUIPMENT MAYBE PROPERLY COORDINATED. SIGHT GLASS, FILTER DRIER, PRESSURE CONTROL, LOW AMBIENT CONTROLS,AND STORE DESIGNER: M. DBREBIKA <br /> E. ALL EQUIPMENT FURNISHED SHALL FIT THE SPACE AVAILABLE WITH CONNECTIONS IN THE WATERPROOF HOUSING. TRAP AND SLOPE REFRIGERANT LINES PER MANUFACTURERS LEEDO AP: N/A <br /> REQUIRED LOCATIONS AND WITH ADEQUATE SPACE FOR OPERATING AND SERVICING. THE RECOMMENDATIONS. INSTALLATION SHALL COMPLY WITH ASHRAE/ANSI STANDARD CHECKED BY: A. FELDMAN <br /> DRAWINGS ARE GENERALLY DIAGRAMMATIC AND INDICATE THE INTENT OF THE INSTALLATION 15. INSTALL UNIT LEVEL ON BASE PAD OR TAILS IN ACCORDANCE WITH <br /> WHILE THE SPECIFICATIONS AND EQUIPMENT LIST DENOTE THE TYPE AND QUALITY OF MATERIAL MANUFACTURERS REQUIREMENTS. COORDINATE EXACT LOCATION WITH LANDLORD MCG PROJECT#: 18531 <br /> AND WORKMANSHIP TO BE USED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT REPRESENTATIVE, STARBUCKS CONSTRUCTION MANAGER AND EXISTING STRUCTURAL MCG PROJ. MANAGER: C. LEE <br /> MEASUREMENTS. WHERE A CONFLICT EXISTS BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, CONDITIONS. MCG PROJ. SPECIALIST: SPARK <br /> THE HIGHER AND/OR MORE COSTLY STANDARD WILL APPLY. THE CONTRACTOR SHALL PROMPTLY <br /> NOTIFY THE ENGINEER WHOSE DECISION SHALL BE FINAL. NO ALLOWANCE WILL BE MADE <br /> SUBSEQUENTLY IN THIS REGARD ON BEHALF OF THE CONTRACTOR AFTER AWARD OF THE Revision Schedule <br /> CONTRACT. <br /> Rev Date By Description <br /> F. THE CONTRACTOR SHALL INSTALL ALL PIPING, DUCTWORK AND EQUIPMENT AS REQUIRED TO <br /> CONFORM TO THE STRUCTURE,AVOID OBSTRUCTIONS, PRESERVE CEILING HEIGHTS AND <br /> HEADROOM AND MAKE ALL EQUIPMENT REQUIRING MAINTENANCE OR REPAIR ACCESSIBLE. <br /> G. TENANT'S CONTRACTOR SHALL BE RESPONSIBLE FOR THE FIELD VERIFICATION OF ALL UTILITY <br /> RUNS AND/OR OTHER IMPROVEMENTS LOCATED ON THE PREMISES PRIOR TO BIDDING. TENANT'S <br /> CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR ALL COSTS RELATING TO THE RELOCATION OF, <br /> DAMAGE TO, REPAIR OF ANY EXISTING UTILITY RUNS AND/OR IMPROVEMENTS WHICH ARE SHEET TITLE: <br /> DAMAGED AS A RESULT OF TENANT'S WORK IN OR AROUND THE PREMISES. ROOF PLAN <br /> H. ALL ROOFING WORK SHALL BE PERFORMED BY LANDLORD'S APPROVED ROOFING <br /> CONTRACTOR AT TENANT'S EXPENSE, IF REQUIRED IN LEASE OR TENANT CRITERIA MANUAL. <br /> I. MECHANICAL CONTRACTOR SHALL PROVIDE TENANT WITH A WRITTEN ONE(1)YEAR <br /> LEGEND Schnackel SCALE:AS SHOWN <br /> MANUFACTURER'S WARRANTY ON ALL HVAC EQUIPMENT PROVIDED AND/OR INSTALLED. THE EX/ST/NG engineers, SHEET NUMBER: <br /> WARRANTY SHALL INCLUDE ALL LABOR, MATERIALS AND THREE(3)ROUTINE SERVICES INCLUDING NewYwkaOmaha aLmAngeles aseatde®Honolulu <br /> FILTER CHANGES DURING A ONE(1)YEAR PERIOD. NEW WORK 800-5810963 ww jdwmcaeLwm <br /> ® NEW TO EX/STING CONNECT/ON 80 South Lake Avenue, Suite 640 Pasadena, CA 91101 M-1102 <br /> SE JOBq:181163 <br />